In stock

Marine Master Waterproof Wireless Multiparameter Photometer – Kit | HI97115C

marine

pH, Alkalinity, Ammonia, Calcium, Magnesium,Nitrate Low Range, Nitrate High Range, NitriteUltra Low Range, Phosphate Ultra Low Range

The HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.

Estimated delivery: 3 - 4 November

Inquire Now
SKU:HI97115C

Marine, Saltwater Aquariums, Aquaculture

Precise and advanced LED optical system

The HI97115C can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.

  • Precise and advanced LED optical system
  • Waterproof and floating IP67 meter design
  • Meter validation using certified CAL Check™ cuvettes
  • Includes auto data logging features to easily record up to 200 water testing results
  • On-screen tutorial mode guides users step-by-step through the measurement process
  • Option to assign locations to logged readings
  • Positive-locking system ensures that the cuvettes are placed into the holder in the same position every time
  • Future compatibility with Hanna Cloud

Innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

diag
HI97106 HANNA SPECS

CAL Check™ Validation

Hanna’s exclusive CAL Check™ feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check™ standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.Tutorial mode can be enabled or disabled from the setup menu.

On-Screen Tutorials

The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents, and quantities.

Tank Selection and Multiple Reading Locations Management

Users can edit up to 25 different tanks, correlate reading location to any location from the list so that logged data is linked to its reading location.

Data Logging

Missed a measurement? No need to worry because your photometer will automatically log the last 200 measurements. The results can be viewed instantly using the Log Recall Menu.


HI97106 HANNA SPECS

Advanced Optical System

A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.

Large Cuvette Size

The 25-mm path length cuvette allows light to pass though more of the sample ensuring accurate measurements even in low-absorbance samples.

Positive Locking System

Cuvettes are placed into the holder in the same position every time by ensuring that the notch on the cap is positioned securely in the cell’s groove.

Portable Design

Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.


Ordering Information:

We believe that buying a meter should be simple. Your HI97115 photometer has many of the necessary accessories needed for successful measurements.

Each HI97115C is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cap (2 pcs.)
  • Alkaline batteries: 1.5V AA (3 pcs.)
  • Instrument quality certificate
  • A quick reference guide with instructions for manual download

HI97115C** is delivered in a rugged carrying case and is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); marine pH reagent, 30 mL dropper (1 pc.), Marine Alkalinity reagent, 30 mL bottle (1 pc.); Marine Ammonia starter kit – reagent A, 30 mL dropper (1 pc.), reagent B and C (reagent for 25 tests, each); Marine Calcium starter kit – reagent A, 30 mL bottle (1 pc.), reagent B (reagent for 25 tests); Marine Magnesium starter kit – reagent A, 120 mL bottle (1 pc.); Magnesium indicator reagent (for 25 tests); Marine Nitrate High Range reagent (reagent for 25 tests); Marine Nitrite Ultra Low Range reagent (reagent for 25 tests); Marine Phosphate Ultra Low Range reagent (reagent for 25 tests); 1 mL graduated syringe with tip (3 pcs.); minipipette with tip (1 pc.); 3 mL Pasteur pipette (2 pcs.); 5 mL syringe with black printing and tip (1 pc.); 5 mL syringe with blue printing and tip (1 pc.); 1.5V AA alkaline batteries (3 pcs.); cloth for wiping cuvettes; scissors; instrument quality certificate; and quick reference guide with instructions for manual download. * CAL Check standards sold separately. Nitrate LR testing reagent not included. ** HI97115UC is instrument code for USA.

Specifications

SKUHI97115C
NameMarine Master Waterproof Wireless Multiparameter Photometer – Kit | HI97115
Marine pH Range6.3 to 8.6 pH
Marine pH Resolution0.1 pH
Marine pH Accuracy±0.2 pH of reading at 25 °C
Marine pH MethodColorimetric Adaptation of the Phenol Red Method
Marine pH LED525 nm
Marine Alkalinity Range0.0 to 20.0 dKH
Marine Alkalinity Resolution0.1 dKH
Marine Alkalinity Accuracy±0.3 dKH ±5 % of reading at 25 °C
Marine Alkalinity MethodColorimetric Method
The reaction causes a distinctive range of colors from yellow to greenish blue to develop.
Marine Alkalinity LED610 nm
Marine Ammonia Range0.00 to 2.50 ppm (as NH₃)
Marine Ammonia Resolution0.01 ppm
Marine Ammonia Accuracy±0.05 ppm ±5% of reading at 25 °C
Marine Ammonia MethodAdaptation of the Salicylate Method The reaction between Ammonia and Ammonium and the reagent causes a blue-green tint in the sample.
Marine Ammonia LED610 nm
Marine Calcium Range200 to 600 ppm
Marine Calcium Resolution1 ppm
Marine Calcium Accuracy±6% of reading at 25 °C
Marine Calcium MethodAdaptation of the Zincon Method
Marine Calcium LED610 nm
Marine Magnesium Range1000 to 1800 ppm (as Mg2+)
Marine Magnesium Resolution5 ppm
Marine Magnesium Accuracy±5% of reading at 25 °C
Marine Magnesium MethodAdaptation of the Colorimetric EDTA Method using calmagite indicator
The reaction between magnesium and the reagents causes a blue to violet tint in the sample.
Marine Magnesium LED610 nm
Marine Nitrate LR Range0.00 to 5.00 ppm (as NO₃–)
Marine Nitrate LR Resolution0.01 ppm
Marine Nitrate LR Accuracy±0.25 ppm ±2% of reading at 25 °C
Marine Nitrate LR MethodZinc Reduction Method
The reaction between nitrate and the reagent causes a pink tint in the sample.
Marine Nitrate LR LED525 nm
Marine Nitrate HR Range0.0 to 75.0 ppm (as NO₃–)
Marine Nitrate HR Resolution0.1 ppm
Marine Nitrate HR Accuracy±2.0 ppm ±5% of reading at 25 °C
Marine Nitrate HR MethodZinc Reduction Method
The reaction between nitrate and the reagent causes a pink tint in the sample.
Marine Nitrate HR LED525 nm
Marine Nitrite ULR Range0 to 200 ppb (as NO₂–-N)
Marine Nitrite ULR Resolution1 ppb
Marine Nitrite ULR Accuracy±10 ppb ±4% of reading at 25 °C
Marine Nitrite ULR MethodAdaptation of the EPA Diazotization Method 354.1
The reaction between nitrite and the reagent causes a pink tint in the sample.
Marine Nitrite ULR LED525 nm
Marine Phosphate ULR Range0.00 to 0.90 ppm
Marine Phosphate ULR Resolution0.01 ppm
Marine Phosphate ULR Accuracy±0.02 ppm ±5% of reading at 25 °C
Marine Phosphate ULR MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method
Marine Phosphate ULR LED610 nm
Measurement System Light sourceLED
Measurement System Bandpass filterwavelength 525 nm & 610 nm
bandwidth 8 nm wavelength accuracy ±1.0 nm
Measurement System Light detectorsilicon photocell
Measurement System Cuvette Typeround 24.6 mm diameter (22 mm inside diameter)
Additional Specifications Auto logging200 readings
Additional Specifications Display128 x 64 pixel B/W LCD with backlight
Additional Specifications Auto-offafter 15 minutes of inactivity (30 minutes before a READ measurement)
Additional Specifications Battery type / Lifealkaline 1.5 V AA (3) / > 800 measurements (without backlight)
Additional Specifications Environment0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
Additional Specifications Dimensions142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)
Additional Specifications Weight380 g (13.4 oz.); with batteries
Additional Specifications CasingIP67 rating, floating

Manuals

Marine Master Waterproof Wireless Multiparameter Photometer – Kit | HI97115

Bestsellers

Portable pH/EC/TDS/Temperature Meter - HI9811-51

753.00 AED
The HI9811-51 is an economical, wateproof, portable meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature (℃) with a single probe. The meter operation is simplified with dedicated buttons for measurement modes to be be displayed on the LCD and knobs for single point calibration of pH and EC/TDS. The HI9811-51 is most suitable for agricultural, greenhouse and hydroponic applications.
  • 3 in 1 probe with pH, EC/TDS and temperature sensors
  • Amplified pH electrode for immunity to electrical noise including from ballasts and pumps
  • Large LCD with instructions

Marine Test Kit - HI3823

1,399.00 AED
The HI3823 is a chemical test kit for the determination of six parameters commonly monitored for aquaculture testing: alkalinity, carbon dioxide, hardness, dissolved oxygen, pH, and salinity. This kit is equipped with all the necessary reagents and equipment to perform over 100 tests for each parameter. pH is obtained with Hanna‘s pHep®, pH electronic tester, which guarantees greater accuracy and a longer life than traditional litmus paper.
  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Portable carrying case for easy transport

Digital Refractometer for Seawater Analysis - HI96822

869.00 AED
The HI96822 is a rugged, portable digital refractometer designed for the measurement of salinity of natural or artificial seawater. The HI96822 displays results in three popular measurement units: Practical Salinity Units (PSU), salinity in parts per thousands (ppt) and specific gravity (S.G. (20/20)). The instrument’s high accuracy and simple operation gives reliable results each and every time. All readings are automatically compensated for temperature variations and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings
Inquire Now

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-Yes-Logging probe - with turbidity-20m (65.6')

19,309.00 AED
The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

Total Hardness Test Kit Replacement Reagents (100 tests) - HI38033-100

62.00 AED
The HI38033-100 are reagents for the determination of total hardness (as CaCO3) by titration with the HI38033 Total Hardness Chemical Test Kit. There are enough reagents for approximately 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Iron Low-Range Checker® Reagents (25 Tests) - HI746-25

147.00 AED
The HI746-25 are the replacement reagents for the HI746 Iron Low-Range Checker® HC. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Burette Assembly for HI903, 5 mL - HI900505

3,531.00 AED
The HI900505 is a 5 mL burette assembly for the HI903 Karl Fischer Titration System. The assembly includes the 5 mL syringe, aspiration tubes, and dispensing tubes, complete with blue protection sleeves, gaskets, and tube locks.
  • Rotating light block shield
  • Easy to install
  • Chemically resistant materials
Back to Top
Whatsapp
Product has been added to your cart