Out of stock

Industrial Flat Tip pH Electrode with PTFE Junction – HI1006

Hanna presents a series of combination pH and ORP electrodes, including more than 300 models, incorporating over 20 years of electrode manufacturing experience.
The most advanced feature of this series is the electrode shape with a flat tip, virtually eliminating deposits that can foul the electrode, significantly reducing necessary maintenance. This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.

  • PVDF body
  • Self-cleaning flat tip sensor for significantly reduced maintenance.
  • Provided with an internal matching pin that can avoid typical problems caused by grounding loop current.
  • ¾” NPT external thread on both ends for easy installation

Inquire Now
SKU:HI1006

A Worldwide Leader in Electrode Manufacturing

Since the beginning of the 1990’s Hanna has been a leader in the research & development of pH and ORP electrodes. Today, Hanna is proud to present the latest family of industrial electrodes, the Flat Tip Series, which completes the wide range of Hanna probes for any process application. All Hanna industrial pH and ORP electrodes are combination type, i.e. the reference half cell and the measurement half cell are assembled in the same body.

Flat tip pH Electrode

Advantage of flat tip electrodes

  • In a continuous in-line installation, the glass sensor of the pH electrode can be physically damaged by solution streams containing suspended solids.
  • Our Flat Tip electrodes are the best answer to this problem. The flat tip virtually eliminates deposits that can foul the electrode, significantly reducing necessary maintenance.
  • This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.
matching pin

Each pH electrode is provided with an internal matching pin that can avoid typical problems caused by grounding loop current, such as:

  • progressive damage of the electrode
  • fluctuating measurements
  • poor process regulation

In many industrial applications, especially in plating baths, grounding loop current is a very common problem.
When a traditional electrode/controller system is used with the electrode reference connected both to the electrode and to the instrument, a current flow occurs through the reference half cell, causing fluctuations in reading and serious damage to the Ag/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above, the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly, the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.

Flat tip pH dimensions

Installation

These electrodes have been designed with ¾” external thread on both ends for easy installation. HANNA instruments® also provides a series of probe holders for in-line, tank or by-pass installations for these electrodes, as shown below.

Front thread ¾” NPT

  • Direct in-line installation ¾” standard tee
  • Immersion installation in vessel, tank, plating bath with HI 60501 (PVC) or HI 60503 (PVDF) electrode holders with adjustable immersion level: min 10 cm, max 70 cm
  • Direct pipe installation with HI 60542 PVC electrode holder, 2″ thread

Back thread ¾” NPT

  • Immersion installation with ¾” threaded pipe
  • By-pass installation with HI 60545 By-pass electrode holder “Loop” configuration Liquid inlet: ¾” Liquid outlet: ¾

HI1006 Series Flat Tip pH Electrode FEATURES/BENEFITS:

Junction

Three junction types are available:

  •  Annular non-clogging PTFE junction, for testing solutions with high content of suspended solids or for high pressure installation
  • Open junction, ideal for wastewater analysis
  • Ceramic junction

Glass Sensor

  • Hanna has developed four types of specialized glass. First is a durable sensor glass for general purpose, industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process and streams significantly increase the electrode life

Temperature Sensor

  • The pH electrodes with built-in 3-wire Pt100 or Pt1000 temperature sensor allow for the temperature compensation of pH readings as well as temperature measurements.

Connection Type

  • Electrodes are wired for direct connection to a transmitter or process controller, or with the standard BNC connector.

Cable Length

  • Non-amplified electrodes are provided with a 5, 10 or 15 m cable (16’, 33’ or 49’)

PVDF Body

  • The PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications, and guarantees a high chemical and mechanical resistance. These characteristics makes the PVDF material the most recommended for many industrial applications. PVDF is also non-toxic and compatible with food applications.

Specifications

SKU HI1006-web
Name Industrial Flat Tip pH Electrode with PTFE Junction – HI1006
Measurement Range GP glass: 0 to 13 pHLT glass: 0 to 12 pHHT glass: 0 to 14 pHHF glass: 0 to 10 pH
Reference Cell Type double junction
Junction Type/Flow Rate PTFE
Type of Electrolyte polymer
Body Material PVDF
Glass Type HT – High TemperatureLT – Low TemperatureGP – General PurposeHF – Hydrofluoric Acid Resistant
Tip / Shape flat
Environment HT glass: -5 to 80 ℃LT glass: -10 to 80 ℃HT glass: 0 to 100 ℃HF glass: -5 to 60 ℃
Matching Pin yes
Max. Pressure 6 bar (87 psi)
Body Length/Overall Length 140 mm
Temperature Sensor none, Pt 100 or Pt 1000, based on selected configuration
Outer Diameter 22.5 mm
Connector Type BNC or direct wire, based on selected configuration

Manuals

Industrial Flat Tip pH Electrode with PTFE Junction – HI1006

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart