In stock

Free and Total Chlorine Test Kit (Low and Medium Range) – HI38017

The HI38017 is a chemical test kit that uses N, N Diethyl-1, 4 Phenylenediamine Sulfate (DPD) to measure free and total chlorine in the low and medium range. The HI38017 is supplied complete with all of the reagents and equipment necessary to perform 200 tests.

  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Checker® disc for more accurate determination

321.00 AED

Estimated delivery: 25 - 26 July

SKU:HI38017
The HI38017 is a chemical test kit that determines the free and total chlorine concentration in two ranges: 0 to 0.7 mg/L and 0 to 3.5 mg/L. The HI38017 is supplied with all of the necessary reagents and equipment to perform both analyses, including the Checker® disc for accurate determination. The test kit contains enough reagents to perform 200 tests.

Features at-a-glance

  • Complete setup
    • All required materials are included with the test kit, such as the glass vials, plastic pipette, reagent packets, and Checker® disc.
  • High resolution
    • Readings from 0.00 to 0.70 mg/L are determined to 0.02 mg/L resolution.
    • Readings from 0.0 to 3.5 mg/L are determined to 0.1 mg/L resolution.
  • Replacement reagents available
    • There is no need to buy a new kit when reagents are exhausted. The HI38017-200 is the part number for replacement reagents. The HI38017-200 is supplied with 100 packets each of HI93701-0 free chlorine and HI93711-0 total chlorine reagents.

Significance of Use

Chlorine is the most commonly used water disinfectant in applications such as drinking water and wastewater treatment, pool and spa sanitization, and food processing and sterilization. Chlorine present in water binds with bacteria, leaving only a part of the original quantity (free chlorine) to continue its disinfecting action. If the free chlorine level is improper with respect to pH, water will have an unpleasant taste and odor and the disinfecting potential of the chlorine will be diminished.

Free chlorine reacts with ammonium ions and organic compounds to form chlorine compounds; this results in diminished disinfecting capabilities compared with free chlorine. Chlorine compounds together with chloramines form combined chlorine. Combined chlorine and free chlorine together result in total chlorine. While free chlorine has a much higher disinfectant potential, combined chlorine has a much higher stability and lower volatility.

Specifications

SKU HI38017
Name Free and Total Chlorine Test Kit (Low and Medium Range) – HI38017
Free Chlorine Measurement Type Checker Disc
Free Chlorine Range Low Range: 0.00 to 0.70 mg/L
Medium Range: 0.0 to 3.5 mg/L
Free Chlorine Resolution 0.02 mg/L (0.00 to 0.70 mg/L range), 0.1 mg/L (0.0 to 3.5 mg/L range)
Free Chlorine Number of Tests 100
Total Chlorine Measurement Type Checker Disc
Total Chlorine Range Low Range: 0.00 to 0.70 mg/L
Medium Range: 0.0 to 3.5 mg/L
Total Chlorine Resolution 0.02 mg/L (0.00 to 0.70 mg/L range), 0.1 mg/L (0.0 to 3.5 mg/L range)
Total Chlorine Number of Tests 100
Chlorine Method DPD
Weight 696 g (24.6 oz)
Dimensions 235x175x115 mm (9.2×6.9×4.5 in.)

Ordering Info

HI38017 test kit comes with HI93701-0 free chlorine reagent (100 packets), HI 93711-0 total chlorine reagent (100 packets), demineralizer bottle with filter cap for 12 L, checker disc, glass vials with caps (2), and 3mL plastic pipette (1).

Manuals

Free and Total Chlorine Test Kit (Low and Medium Range) – HI38017

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range Checker® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

Checker® pH Tester with 0.1 pH Resolution - HI98103

132.00 AED
The HI98103 Checker is the next generation of the original Hanna Checker pH tester. The Checker is the most popular pH meter in the world with over 1 million meters used since its introduction in 1991. From students to researchers, the Checker has been helping people with their pH measurement as a meter that is simple to use and operate.
  • One-button operation
  • Replaceable pH electrode
  • ±0.2 pH accuracy
Back to Top
Whatsapp
Product has been added to your cart