Out of stock

Foodcare pH Electrode for Yogurt and Creams with BNC Connector – FC210B

The FC210B is a glass body, double junction pH electrode that has a BNC connector. The FC210B electrode features an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape.

This design consideration is ideal for pH measurements in products such as cream, yogurt, or other semi-solid or emulsified samples. The recommended operating temperature range is from 0 to 50℃.

  • Low Temperature Glass
  • Conical Tip
  • Open Junction

807.00 AED

Inquire Now
SKU:FC210B

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The FC210B is a double junction pH electrode that uses low temperature (LT) glass, conical bulb, glass body, and open junction with viscolene gel electrolyte.

low temperature glass

Low Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The FC210B is suitable to use with samples that measure from 0 to 50℃.

conical tip

Conical Glass Tip

The conical shaped tip design allows for penetration into solids, semi solids, and emulsions for the direct measurement of pH in food products including meat, cheese, yogurt, and milk.

glass body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

open junction reference

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

bnc connector

BNC Connector

The FC210B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Single Junction Versus Double Junction pH Electrodes

single vs double junction

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

Specifications

SKU FC210B
Name Foodcare pH Electrode for Yogurt and Creams with BNC Connector – FC210B
Measurement Range pH: 0 to 12
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material glass
Tip / Shape conic (12 x 12 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50°C (32 to 122°F) – LT
Body Length/Overall Length 120 mm / 160 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use creams, milk, yogurt

Manuals

Foodcare pH Electrode for Yogurt and Creams with BNC Connector – FC210B

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration
Back to Top
Whatsapp
Product has been added to your cart