Out of stock

Flat Tip pH Electrode for Skin and Surfaces with DIN Connector – HI1414D

The HI1414D is a glass body, single reference junction pH electrode made with low temperature glass and a DIN connector. This pre-amplified electrode features a built-in temperature sensor for temperature compensated measurements in a single probe design.

This electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe’s flat tip makes it ideal for pH measurements on surfaces such as skin, leather, and paper. The HI1414D is recommended for use with Hanna’s HI99171 pH meter.

  • Open Junction
  • Flat Tip
  • Built-In Temperature Sensor

618.00 AED

Inquire Now
SKU:HI1414D

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1414D uses low temperature (LT) glass, flat tip bulb, glass body, and open junction with viscolene gel electrolyte.

Glass

Low Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The HI1414D is suitable to use with samples that measure from 0 to 50℃.

Flat Tip

Flat Glass Tip

A flat tip is recommended to optimize surface contact for measurement on skin, leather, paper, and samples that cannot easily be penetrated.

glass Body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Open Junction

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

DIN connector

DIN Connector

The HI1414D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI1414D is recommended for use with Hanna’s HI99171 pH meter. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few.

Specifications

SKU HI1414D
Name Flat Tip pH Electrode for Skin and Surfaces with DIN Connector – HI1414D
Measurement Range pH: 0 to 12
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material glass
Tip / Shape flat
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50°C (32 to 122°F)
Body Length/Overall Length 110 mm / 153.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 7-pole; 1 m (3.3 in.)
Connector Type DIN
Amplifier yes
Recommended Use emulsions, leather, paper, skin, surface

Manuals

Flat Tip pH Electrode for Skin and Surfaces with DIN Connector – HI1414D

Bestsellers

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range Checker® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
Inquire Now

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Back to Top
Whatsapp
Product has been added to your cart