Out of stock

Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B

The HI1413B is a glass body, single reference junction pH electrode made with low temperature glass and a BNC connector. This electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe’s flat tip makes it ideal for pH measurements on surfaces such as skin, leather, and paper.

Open Junction

Flat Tip

Viscolene Gel Electrolyte

618.00 AED

Inquire Now
SKU:HI1413B

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1413B uses low temperature (LT) glass, flat tip bulb, glass body, and open junction with viscolene gel electrolyte.

Glass

Low Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The HI1413B is suitable to use with samples that measure from 0 to 50ā„ƒ.

Flat Tip

Flat Glass Tip

A flat tip is recommended to optimize surface contact for measurement on skin, leather, paper, and samples that cannot easily be penetrated.

glass Body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Open Junction

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

bnc connector

BNC Connector

The HI1413B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Specifications

SKU HI1413B
Name Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B
Measurement Range pH: 0 to 12
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material glass
Tip / Shape flat
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50°C (32 to 122°F) – LT
Body Length/Overall Length 110 mm / 153.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use emulsions, leather, paper, skin, surface

Manuals

Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B

Bestsellers

Inquire Now

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

84 µS/cm Conductivity Standard (1 L) – HI7033/1L

77.00 AED
HI7033/1L is a premium quality 84 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

GroLine pH 7.01 Calibration Buffer (500mL) - HI7007-050

61.00 AED
HI7007-050 is a high quality pH 7.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Digital Refractometer for Brix Analysis in Foods - HI96801

869.00 AED
The HI96801 is a rugged, portable digital refractometer for food products designed to report the sugar content of aqueous solutions as % Brix. The HI96801 report the results with an accuracy of ±0.2% Brix. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

COD Test Tube Heater - HI839800 (230V)

4,600.00 AED
The HI839800 COD Test Tube Heater is an easy to use thermoreactor constructed of durable materials. The aluminum block incorporates a 25 vial capacity and a well for a reference temperature probe. Its well-marked user interface provides intuitive operation, equipped with two arrows to set the built-in timer and a temperature button with two predefined temperature settings: 150ā„ƒ and 105ā„ƒ. Additional features include status indicator lights, a thermal fuse to prevent overheating, and continuous LCD display.
  • Low and high temperature alerts
  • Built-in countdown timer
  • Status indicator lights

Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)

4,584.00 AED
HI83314 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterWastewater Treatment Digestion ParametersMeasures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus
Back to Top
Whatsapp
Product has been added to your cart