2 in stock

Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B

The HI1413B is a glass body, single reference junction pH electrode made with low temperature glass and a BNC connector. This electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe’s flat tip makes it ideal for pH measurements on surfaces such as skin, leather, and paper.

Open Junction

Flat Tip

Viscolene Gel Electrolyte

633 AED

Estimated delivery: 29 - 30 April

SKU:HI1413B

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI1413B uses low temperature (LT) glass, flat tip bulb, glass body, and open junction with viscolene gel electrolyte.

Glass

Low Temperature Glass Formulation

The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The HI1413B is suitable to use with samples that measure from 0 to 50ā„ƒ.

Flat Tip

Flat Glass Tip

A flat tip is recommended to optimize surface contact for measurement on skin, leather, paper, and samples that cannot easily be penetrated.

glass Body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

Open Junction

Open Junction Reference

Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable readings.

bnc connector

BNC Connector

The HI1413B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Specifications

SKU HI1413B
Name Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B
Measurement Range pH: 0 to 12
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material glass
Tip / Shape flat
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50Ā°C (32 to 122Ā°F) – LT
Body Length/Overall Length 110 mm / 153.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use emulsions, leather, paper, skin, surface

Manuals

Flat Tip pH Electrode for Skin and Surfaces with BNC Connector – HI1413B

Bestsellers

Digital Glass Body pH Electrode for General Purpose - HI11310

673 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Refillable Combination pH Electrode with BNC Connector - HI1131B

590 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

Digital Glass Body pH Electrode with Matching Pin for General Purpose - HI11311

764 AED
The HI11311 is a glass body, refillable, double junction pH electrode with a matching pin andĀ a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI11311 is for the Sensor Checkā„¢ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI11311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

Free Chlorine Test Kit - HI3831F

104 AED
The HI3831F is a chemical test kit that uses the DPD method to measure free chlorine. The HI3831F is supplied complete with all of the reagents and equipment necessary to perform approximately 50 tests.
  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Color comparison cube for simple determination

ChecktempĀ® 1 Digital Thermometer - HI98509

174 AED
The HI98509 ChecktempĀ® 1 is a high-accuracy thermometer with a 1 m (3.3ā€™) flexible, silicone cable connecting the meter and the stainless steel probe. The sharp-tip penetration probe easily lances semi-solid products such as fruits, vegetables, and cheeses. This probe can also handle liquid, air and measurements in frozen materials. The probe incorporates an NTC thermistor sensor to measure the temperature.
  • CAL Checkā„¢
  • ā„ƒ/ā„‰ readout

HI763100 - Digital EC/Temperature Electrode

1,643 AED
The HI 763100 is a digital conductivity electrode with a built-in temperature sensor. Compared to the amperometric design of other conductivity probes, the HI 763100 is potentiometric probe with platinum sensors which allows for the possibility to measure high or low conductivity ranges using one probe. This electrode features an integrated microchip which stores calibration data, electrode type, and serial number. The HI 763100 is designed for use with Hannaā€™s edgeĀ® pH/EC/DO meter.
  • Digital Probe with Built-in Microchip
  • Internal Temperature Sensor
  • 3.5 mm Connector

Total Hardness Colorimetric Reagents (100 tests) - HI93735-0

487 AED
The HI93735-0 are reagents for low, medium, and high range colorimetric determination of total hardness. There are enough reagents for 100 tests to be used with Hannaā€™s HI96735 Total Hardness EPA Portable Photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Back to Top
img
Product has been added to your cart