In stock

Digital Refractometer for Refractive Index and Brix – HI96800

Hanna’s new HI96800 Digital Refractometer measures Refractive Index and displays results in both temperature compensated (nD20) and non-temperature compensated (nD) formats on the dual-level LCD screen. The HI96800’s intuitive layout and pinpoint accuracy ensures effortless operation and reliable readings every time.

Refractive Index is measured to determine a liquid’s composition and assess its concentration and density. It is used by many industries including pharmaceutical, food and environmental, as an important indicator of quality and consistency. The HI96800 also converts Refractive Index to % Brix with the push of a single button.

  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

1,292 AED

Estimated delivery: 10 - 11 September

SKU:HI96800

Hanna Instruments new HI96800 Digital Refractometer combines form and function into one compact unit. Featuring a 1.5 second response time, the HI96800 measures refractive index from 1.3330 to 1.5040 with temperature compensation (nD20) and from 1.3300 to 1.5080 without temperature compensation (nD). For added versatility the refractometer also converts refractive index to % Brix (0-85%). One-button calibration makes setup quick and easy.

The improved easy-to-read LCD screen displays temperature units (℃ or ℉) and measurements simultaneously. By pressing the ‘Range’ key, users can easily switch between refractive index (nD), refractive index (nD20) and % Brix readings while in measurement mode. The HI96800’s IP65 water-resistant casing and sealed sample well is built to perform under harsh conditions, making it suitable for use in the field or in the laboratory.

  • 1.3300-1.5080 Refractive Index range with ±0.0005 accuracy
  • 0-85% Brix range with ±0.2% accuracy
  • Simple one-button calibration
  • Automatic Temperature Compensation (ATC) and No Temperature Compensation Settings (NoTC)
refractive index

Refractive Index

The HI96800 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96800 uses an LED light, prism and lens to make measurement possible.

Variations in temperature will affect the accuracy of refractive index readings, so the use of temperature compensation is highly recommended for reliable results. The HI96800 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book Standard for a percent by weight sucrose solution at 20℃. These compensation algorithms vary based on the parameter being measured. The user can switch between temperature compensated (nD20), non-temperature compensated (nD) and temperature compensated % Brix readings by pressing the ‘Range’ key while in measurement mode.

Features at-a-glance:

One-point calibration

  • Calibrate with distilled or deionized water

Small sample size

  • Sample size can be as small as 2 metric drops (100 μl)

Automatic Temperature Compensation (ATC)

  • Automatically compensates for temperature variations

Quick, accurate results

  • Readings are displayed in approximately 1.5 seconds

Upgraded Dual-level LCD

  • The large LCD screen displays nD20, nD or % Brix and temperature readings simultaneously

Stainless steel sample well

  • Easy to clean and corrosion-resistant

Battery indicators

  • Battery percent level remaining at startup and low battery indicator

Automatic shut-off

  • Conserves battery life by shutting off automatically after three minutes of inactivity

IP65 water resistant protection

  • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.

Video

a4dead304f9c3f3b04043143fe909967224479a6

Specifications

SKU HI96800
Name Digital Refractometer for Refractive Index and Brix – HI96800
Sugar Content Range 0.0 to 85.0% Brix; 1.3300 to 1.5080 nD; 1.3330 to 1.5040 nD₂₀
Sugar Content Resolution 0.1 % Brix; 0.0001 nD; 0.0001 nD₂₀
Sugar Content Accuracy ±0.2% Brix; ±0.0005 nD; ±0.0005 nD₂₀
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Automatic Shut-Off after three minutes of inactivity
Battery Type/Life 9V / approximately 5000 readings
Dimensions 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight 420 g (14.8 oz.)
Refractometer Light Source yellow LED
Minimum Sample Volume 100 µL (to cover prism totally)
Sample Cell stainless steel ring and flint glass prism
Measurement Time approximately 1.5 seconds

Ordering Info

HI96800 is supplied with battery and instruction manual

Manuals

Digital Refractometer for Refractive Index and Brix – HI96800

Bestsellers

Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

288 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
Inquire Now

® Multiparameter EC/TDS/Salinity Meter - HI2030

2,530 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

932 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.
Inquire Now

® Multiparameter pH Meter - HI2020

1,693 AED
edge® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with a simplified menu and options. For those who require advanced features there is the full featured standard operating mode. The edge HI2020 pH kit can be upgraded at any time with additional probes to measure Conductivity or Dissolved Oxygen.

HI12883 pH/EC/TDS Multiparameter Probe with Quick Connect DIN Connector

583 AED
The HI12883 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance free polymer gel electrolyte, and a low temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two graphite sensors for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI12883 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatemnt and boilers and cooling towers. The HI12883 is designed for use with Hanna’s HI991300 and HI991301 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor
Inquire Now

pH Electrode for Beer Analysis - FC2143

681 AED
The FC2143 is a titanium body, gel filled, single reference junction pH electrode. This electrode features low temperature glass and an extendable cloth type junction, along with a built-in temperature sensor and amplifier in a single probe design. This design consideration is ideal for measuring the pH of mash or wort during the beer making process. The FC2143 is the replacement pH/temperature probe supplied with the HI99151 portable meter for beer.
  • Low Temperature Glass
  • Titanium Body
  • Built-in Temperature Sensor
Inquire Now

pH Electrode with Clogging Prevention System (CPS™) and BNC Connector - HI1048B

823 AED
The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
  • Clogging Prevention System (CPS™) Technology
  • Refillable Electrode
  • Double Junction Design
Back to Top