In stock

Digital Refractometer for Refractive Index and Brix – HI96800

Hanna’s new HI96800 Digital Refractometer measures Refractive Index and displays results in both temperature compensated (nD20) and non-temperature compensated (nD) formats on the dual-level LCD screen. The HI96800’s intuitive layout and pinpoint accuracy ensures effortless operation and reliable readings every time.

Refractive Index is measured to determine a liquid’s composition and assess its concentration and density. It is used by many industries including pharmaceutical, food and environmental, as an important indicator of quality and consistency. The HI96800 also converts Refractive Index to % Brix with the push of a single button.

  • Sample size as small as 2 metric drops (100 µl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

1,371.00 AED

Estimated delivery: 13 - 14 October

SKU:HI96800

Hanna Instruments new HI96800 Digital Refractometer combines form and function into one compact unit. Featuring a 1.5 second response time, the HI96800 measures refractive index from 1.3330 to 1.5040 with temperature compensation (nD20) and from 1.3300 to 1.5080 without temperature compensation (nD). For added versatility the refractometer also converts refractive index to % Brix (0-85%). One-button calibration makes setup quick and easy.

The improved easy-to-read LCD screen displays temperature units (℃ or ℉) and measurements simultaneously. By pressing the ‘Range’ key, users can easily switch between refractive index (nD), refractive index (nD20) and % Brix readings while in measurement mode. The HI96800’s IP65 water-resistant casing and sealed sample well is built to perform under harsh conditions, making it suitable for use in the field or in the laboratory.

  • 1.3300-1.5080 Refractive Index range with ±0.0005 accuracy
  • 0-85% Brix range with ±0.2% accuracy
  • Simple one-button calibration
  • Automatic Temperature Compensation (ATC) and No Temperature Compensation Settings (NoTC)
refractive index

Refractive Index

The HI96800 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96800 uses an LED light, prism and lens to make measurement possible.

Variations in temperature will affect the accuracy of refractive index readings, so the use of temperature compensation is highly recommended for reliable results. The HI96800 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book Standard for a percent by weight sucrose solution at 20℃. These compensation algorithms vary based on the parameter being measured. The user can switch between temperature compensated (nD20), non-temperature compensated (nD) and temperature compensated % Brix readings by pressing the ‘Range’ key while in measurement mode.

Features at-a-glance:

One-point calibration

  • Calibrate with distilled or deionized water

Small sample size

  • Sample size can be as small as 2 metric drops (100 μl)

Automatic Temperature Compensation (ATC)

  • Automatically compensates for temperature variations

Quick, accurate results

  • Readings are displayed in approximately 1.5 seconds

Upgraded Dual-level LCD

  • The large LCD screen displays nD20, nD or % Brix and temperature readings simultaneously

Stainless steel sample well

  • Easy to clean and corrosion-resistant

Battery indicators

  • Battery percent level remaining at startup and low battery indicator

Automatic shut-off

  • Conserves battery life by shutting off automatically after three minutes of inactivity

IP65 water resistant protection

  • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.

Video

a4dead304f9c3f3b04043143fe909967224479a6

Specifications

SKU HI96800
Name Digital Refractometer for Refractive Index and Brix – HI96800
Sugar Content Range 0.0 to 85.0% Brix; 1.3300 to 1.5080 nD; 1.3330 to 1.5040 nD₂₀
Sugar Content Resolution 0.1 % Brix; 0.0001 nD; 0.0001 nD₂₀
Sugar Content Accuracy ±0.2% Brix; ±0.0005 nD; ±0.0005 nD₂₀
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Automatic Shut-Off after three minutes of inactivity
Battery Type/Life 9V / approximately 5000 readings
Dimensions 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight 420 g (14.8 oz.)
Refractometer Light Source yellow LED
Minimum Sample Volume 100 µL (to cover prism totally)
Sample Cell stainless steel ring and flint glass prism
Measurement Time approximately 1.5 seconds

Ordering Info

HI96800 is supplied with battery and instruction manual

Manuals

Digital Refractometer for Refractive Index and Brix – HI96800

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart