Out of stock

COD Low Range Reagent Vials with Barcode, EPA Method (25 tests) – HI94754A-25

The HI94754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-dosed reagents for ease of use
  • Barcoded vials
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground.
    For Professional Use Only.

    241.00 AED

    Inquire Now
    SKU:HI94754A-25

    The HI94754A-25 COD kit contains 25 ready-to-use, barcoded vials containing pre-measured reagents. These high quality reagents follow the EPA approved method 410.4. In this method, a heated digestion under acidic conditions is required to allow the oxidizable organic compounds present in the sample to reduce hexavalent chromium to trivalent chromium, causing an orange tint in the sample. The intensity of color is determined by a compatible photometer and the COD concentration is displayed in mg/L (ppm) O2. These reagents are designed to be used with samples that have an expected range of 0 to 150 mg/L (ppm) O2.

    Automatic recognition of barcoded samples is an exciting feature when using the HI94754A-25 reagent vials with a barcode compatible photometer. When inserted into the vial holder of the photometer, the sample method and range are automatically identified from the barcode. The barcode has four digits: the first two digits are for parameter identification and the second two digits are for reagent lot ID. Vials for different COD methods can be distinguished by a barcode printed on the vial – the barcodes for different methods are shown in the table below.

    Comparison of Methods

    EPA – The EPA approved method 410.4 for COD determination requires the use of mercuric sulfate (HgSO4). Mercuric sulfate is present in the EPA reagent vials to mitigate the interference of chloride in the measurement sample. This is a common requirement for wastewater treatment plants and food manufacturing facilities which tend to have higher concentrations of chloride present in their effluent. When using reagents that follow the EPA method, it is important to treat used vials as hazardous waste, as mercury waste requires recycling.

    Dichromate – The dichromate method is adapted from the standard EPA and ISO methods for determination of COD, which are approved to measure COD concentrations ranging up to 1500 mg/L O2. For samples with expected concentrations in the high range of 0 to 15000 mg/L O2, the dichromate reagents can be used for accurate COD determination. It is important to treat used vials as hazardous waste, as mercury waste requires recycling.

    Mercury-free – For those who do not wish to handle mercury reagents, our “green, ” mercury-free reagents are available for COD determination. These reagents are more sensitive to chloride interferences, as mercuric sulfate is not present. While the mercury-free reagents are easier to dispose of, they may be unacceptable for reporting purposes.

    ISO – The ISO approved method 15705 for COD determination also requires the use of mercuric sulfate (HgSO4) to reduce the interference of chloride. Containing similar chemical reagents as the EPA method, it is important to treat used ISO vials as hazardous waste, as mercury waste requires recycling.

    Method

    Parameter

    Range (as O2)

    Resolution

    Accuracy

    Reagent Code

    EPA

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI94754A-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI94754B-25

    Dichromate

    COD HR

    0 to 15000 mg/L

    10 mg/L

    ±150 mg/L ±3% of reading

    HI94754C-25

    Mercury-free

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI94754D-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI94754E-25

    ISO

    COD LR

    0 to 150 mg/L

    1 mg/L

    ±5 mg/L ±5% of reading

    HI94754F-25

    COD MR

    0 to 1500 mg/L

    1 mg/L

    ±15 mg/L ±4% of reading

    HI94754G-25

    Specifications

    SKU HI94754A-25
    Name COD Low Range Reagent Vials with Barcode, EPA Method (25 tests) – HI94754A-25
    Package vials
    Quantity 25
    Method dichromate EPA

    Manuals

    COD Low Range Reagent Vials with Barcode, EPA Method (25 tests) – HI94754A-25

    Bestsellers

    Inquire Now

    Hydrochloric Acid 0.1N, 1L - HI70463

    86.00 AED
    HI70463 is a hydrochloric acid titrant for use in standard acid-base titrations. Hanna titration solutions and reagents have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Air-Tight
    • Acid-Base Reagent
    • Tamper-Proof Seal
    Inquire Now

    Hydrochloric Acid 1N, 1L - HI70464

    HI70464 is a hydrochloric acid titrant for use in standard acid-base titrations. Hanna titration solutions and reagents have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
    • Air-Tight
    • Acid-Base Reagent
    • Tamper-Proof Seal

    Marine Nitrate Low Range Checker Reagents (25 tests) - HI781-25

    Original price was: 80.00 AED.Current price is: 77.00 AED.
    HI781-25 Marine Nitrate Low Range Checker HC (Handheld Colorimeter) Reagents are high-quality reagents for use with the HI781 Marine Nitrate Low Range Checker HC. They are manufactured in our state-of-the-art facility and clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high-purity chemicals
    • Marked with expiration date and lot number for traceability

    Ultra High Range Chlorine Reagents (300 tests) - HI95771-03

    340.00 AED
    The HI95771-03 are reagents for the colorimetric determination of chlorine in the ultra high range. There are enough reagents for 300 tests to be used with Hanna’s HI96771 portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-dosed reagents for ease of use
    • Supplied with certificate of quality
    • Marked with expiration date and lot number for traceability
    Inquire Now

    Oxygen Scavengers Reagents (50 tests) – HI96773-01

    264.00 AED
    The HI96773-01 are reagents for the colorimetric determination of oxygen scavengers. There are enough reagents for 50 tests to be used with Hanna’s compatible photometers. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high-purity chemicals
    • Marked with expiration date and lot number
    Inquire Now

    Iodine Reagents (300 tests) - HI93718-03

    275.00 AED
    The HI93718-03 are reagents for the colorimetric determination of iodine (I2). There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-dosed reagents for ease of use
    • Supplied with certificate of quality
    • Marked with expiration date and lot number for traceability

    Ammonia Test Kit for Seawater Replacement Reagents (25 tests) - HI3826-025

    108.00 AED
    The HI3826-025 are replacement reagents for the colorimetric determination of ammonia (as NH3-N) with the HI3826 Ammonia Test Kit for Seawater. There are enough reagents for approximately 25 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high purity chemicals
    • Marked with expiration date and lot number for traceability
    Back to Top