-
-
Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 (230V)
24,584.00 AED4,125.60 AED -
COD Test Tube Heater - HI839800 (230V)
24,600.00 AED4,140.00 AED -

In stock
Chemical Oxygen Demand Portable Photometer – HI97106
Low, Medium, High, Ultra High Range
The HI97106 is a waterproof portable photometer with an advanced optical system that uses a Light Emitting Diode and a narrow band interference filter for accurate, repeatable readings. The optical system is sealed from outside dust, dirt, and water.
The meter uses an exclusive positive-locking system to ensure that the vials are placed into the holder in the same position every time.
The HI97106 is a waterproof chemical oxygen demand portable photometer with an advanced optical system that uses a Light Emitting Diode and a narrow band interference filter for accurate, repeatable readings. The optical system is sealed from outside dust, dirt, and water.
1,255.00 AED
Estimated delivery: 23 - 24 December
The meter uses an exclusive positive-locking system to ensure that the vials are placed into the holder in the same position every time.
With the CAL Check™ functionality, users are able to validate instrument performance at any time. Hanna Instruments® CAL Check cuvettes are certified against NIST-traceable reference instrument(s).
The built-in tutorial mode guides users step-by-step through the measurement process. The tutorial mode includes all steps required for sample preparation, the required reagents, and quantities. The instrument is a compact and versatile photometer designed to accurately determine chemical oxygen demand.

Dedicated help
A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

CAL Check™ validation
Validate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards.

Auto-data logging
Data autolog helps users keep track of all measurements. Data is automatically saved every time a measurement is made.
The data log can hold 200 individual measurements. When the data log is full, the meter will rewrite the oldest data point.

Setup Menu
Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.

Battery status indicator
The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

On-Screen tutorials
Step-by-step on-screen guidance.
The instrument is a compact and versatile photometer designed to accurately determine chemical oxygen demand.
Suitable for field or bench measurements, the photometer features:
Sophisticated optical system
Waterproof IP67, floating case
Backlit LCD
The 128 x 64 Pixel LCD allows for a simplified user interfacer.
Meter validation using certified CAL Check cuvettes • Tutorial mode guides the user step-by-step
Includes auto-data logging features to easily record water testing results
Battery status indicator and auto-shut off
The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order to conserve battery life.
Compact size
Measures 142.5 mm (5.6”) x 102.5 mm (4”) and only 50.5 mm (2”) thick.
Primary Applications:
Industrial and Municipal Wastewater Treatment
Ordering Information:
HI97106 is supplied with adapter for 16 mm vial, 1.5V AA Alkaline batteries (3 pcs.), instrument quality certificate, and quick reference guide with instructions for manual download.
Specifications
| SKU | HI97106 |
| Name | Chemical Oxygen Demand Portable Photometer – HI97106 |
| Chemical Oxygen Demand LR Range | 0 to 150 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±5 mg/L or ±4 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 420 nm |
| Chemical Oxygen Demand MR Range | 0 to 1500 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±15 mg/L or ±4 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand HR Range | 0 to 15000 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±150 mg/L or ±2 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand UHR Range | 0 to 60.0 g/L (as O₂) |
| Resolution | 0.1 g/L |
| Accuracy | ±0.5 g/L ±3 % of reading at 25 °C |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Measurement system Light source | LED |
| Bandpass filter | wavelength: 420 nm & 610 nm / bandwidth: 8 nm wavelength accuracy ±1.0 nm |
| Light detector | silicon photocell |
| Cuvette Type | round, 16 mm diameter |
| Photometer Specifications Auto logging | 200 readings |
| Display | 128 x 64 pixel B/W LCD with backlight |
| Auto-off | After 15 minutes of inactivity (after 30 minutes of inactivity if a Zero has been done but not a Read) |
| Battery type / Life | 1.5 V AA alkaline (3 pcs.) / > 10000 measurements (without backlight) |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100 % RH, non-serviceable |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.) |
| Weight | 380 g (13.4 oz.); with batteries |
| Casing | IP67 rating, floating |










