In stock

Advanced pH/ORP Benchtop Meter- HI6221-02 (230V)

HI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH / ORP measurement module.

systemUI

3,184.00 AED

Estimated delivery: 4 - 5 October

SKU:HI6221-02

Laboratory

Measure pH/mV (pH) or mV/Rel. mV (ORP) with Temperature

HI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH / ORP measurement module.

Compact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.

HI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.


front back

This system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.

User interface

  • 7-inch capacitive touch screen with multi-touch support
  • Capacitive touch back, home and system menu keys
  • User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.
  • The user can select between five different views:
    • Basic measurement configuration
    • Simple GLP with calibration information
    • Full GLP with electrode status and calibration point details
    • Live updated, interactive graph
    • Tabulated data with date, time, and notes

Measurement

  • Measure pH/mV (pH) or mV/Rel.mV (ORP) with temperature
  • Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings
  • Active log during measurement o Measurement stability indicator (using the Stability Criteria setting)
  • Reading modes: direct and direct/autohold
  • Temperature compensation can be Automatic (using temperature probe) or set manually
  • Audible and/or alarm messages for measurements outside of predefined limits
  • Galvanic isolation for pH/ORP measurement

Calibration

  • 5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)
  • Choice of standard or custom buffers for calibration
  • Non-volatile memory saves data and settings

Logging

  • Data log collection of at least 1, 000, 000 data points (with time and date stamp)
  • Logging types: manual, automatic, autohold
  • Sample ID for manual and Autohold data

Connectivity features & services

  • Transfer logged data to a USB thumb drive
  • Log files that include measurements and calibration data (as .csv file)
  • FTP and email for log export via Ethernet and Wi-Fi connection
  • USB type A for USB stick, keyboard, and printer
  • USB type C for USB stick and PC connection

Help section for meter guidance

  • Video support presentation of main functionalities

Customize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.

LF HI6221 1p0 1222 Page 08 Image 0007

LF HI6221 1p0 1222 Page 02 Image 0001

Capacitive touch screen with multi-touch support

The benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.

System Menu key

This key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.

Measurement setup menu

Opens sensor setup parameters.

Direct/Autohold readings

When Direct/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.

When not selected, sample measurements are displayed continuously.


HI6221 is supplied with:

  • HI1131B pH electrode; HI7662-TW temperature probe
  • pH calibration starter kit consisting of:
    • pH 4.01 buffer solution sachet (2 pcs.)
    • pH 7.01 buffer solution sachet (4 pcs.)
    • pH 10.01 buffer solution sachet (2 pcs.)
  • HI700601 electrode cleaning solution sachet (2 pcs.)
  • HI7082 3.5M KCl electrolyte solution (30 mL)
  • HI764060 electrode holder
  • Capillary pipette
  • 24 VDC power adapter
  • USB-C to USB-A cable
  • Quick reference guide with instrument quality certificate.

Specifications

SKU HI6221-02
Name Advanced pH/ORP Benchtop Meter- HI6221-02
pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to
pH Range 20.000 pH
pH Resolution 0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
mV Range ±2000.0 mV
mV Resolution 1 mV; 0.1 mV
mV Accuracy ±0.2 mV ±1 last significant digit
Temperature Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K
Temperature Resolution 0.1 °C / 0.1 °F / 0.1 K
Temperature Accuracy ±0.2 °C / ±0.4 °F / ±0.2 K
Relative mV offset range ±2000.0 mV
pH Calibration Calibration points Up to 5
pH Calibration Type Automatic; Semiautomatic; Manual
pH Calibration Standard buffers Hanna and NIST
pH Calibration Standard buffers pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
pH Calibration Custom buffers Up to 5
pH Calibration Custom group Up to 5
pH Calibration 1st calibration point Offset or Points (user setting)
pH Calibration Reminder Disabled
pH Calibration Reminder Daily: 0 m in. to 23 hours and 59 m in.
pH Calibration Reminder Periodic: 1 m in. to 500 days, 23 hours and 59 m in.
Temperature Compensation Automatic or Manual
Reading Modes Direct; Direct/Autohold
Reading Stability criteria Accurate; Medium; Fast
Reading Isopotential 7.000 or 4.010
Reading Sampling rate 1000 ms
pH Views Basic Measurement (pH, mV, Rel.mV, Abs.mV)
pH Views Basic Temperature, Stability status
pH Views Simple GLP Basic view information
pH Views Simple GLP Last calibration date, electrode offset, average slope, and electrode condition
pH Views Full GLP Simple GLP information and calibration point details
pH Views Table Measurements updated every second are displayed in table
pH Views Graph (Plot) pH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)
Logging Type Automatic, Manual, Autohold
Logging Number of records 50 000 maximum per file / Stores at least 1 000 000 data points per user
Logging Automatic interval 1, 2, 5, 10, 30 seconds
Logging Automatic interval 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
Logging Sample ID Incremental mode
Logging Export option .csv file format
Logging Export option Users Up to 9 users and adm in. account (default):
Connectivity USB-A 2 ports for keyboard input or USB thumb drive
Connectivity USB-C 1 port for PC connectivity and USB-C type thumb drive
Connectivity Wi-Fi & Ethernet FTP / Web server Log transfer and download Email
Connectivity RS232 Connecting peripherals
Power supply DC adapter 100-240AC to 24VDC 2.5A
Environment 0 – 50 °C / 32 – 122 °F / 273 – 323 K maximum 95% RH non-condensing
Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
Weight Approximately 1.2 kg (2.65 lbs.)

Manuals

Advanced pH/ORP Benchtop Meter- HI6221-02

Bestsellers

Inquire Now

edgeĀ® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5ā€ thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

edgeĀ® Dedicated pH/ORP Meter - HI2002

1,583.00 AED
edgeĀ® pH is seriously thin and light with lab grade functionality packed into a tablet design. With simple operation and advanced features, edge pH easily outperforms all other portables and benchtops in its class. Your edge meter will automatically recognize each digital electrode, providing sensor type, calibration data, and serial number. Advanced pH electrode diagnostics ensure worry-free measurements. Use your edge pH meter as a portable, benchtop meter, or mount it on the wall to save space.
  • Stunning 5.5 inch screen with 150° viewing angle provide one of the easiest to read LCDs in the industry.
  • Built for everyone from educators and researchers to home users.
  • Inquire Now

    edgeĀ® Multiparameter pH Meter - HI2020

    1,795.00 AED
    edgeĀ® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5ā€ thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with a simplified menu and options. For those who require advanced features there is the full featured standard operating mode. The edge HI2020 pH kit can be upgraded at any time with additional probes to measure Conductivity or Dissolved Oxygen.
    Inquire Now

    edgeĀ® Wine pH Meter (kit) - HI2020W

    edge® digital pH meter for wine kit delivers precision while offering simplicity and versatility in a sleek design. Upgrade to the Hanna edge® wine pH kit for professional winemakers. The HI2020W allows you to add a conductivity probe and a dissolved oxygen probe to give you full versatility. Fast results, ultra-accurate, hassle-free analysis.
    • Complete meter kit for measuring pH in wine.
    • CAL Checkā„¢ feature ensures the accuracy of the meter.
    • Great for professional and home winemakers.
    Inquire Now

    Benchtop Dissolved Oxygen Meter - HI2400

    The HI2400 is a durable and accurate benchtop meter that measures dissolved oxygen in mg/L (ppm) or percent saturation. DO measurements are automatically compensated for altitude (up to 4000 m) and salinity (up to 40 g/L) based on the user settings. The meter also offers automatic temperature compensation from the built-in temperature sensor of the supplied polarographic DO probe. This probe features easy to install screw cap membranes for quick replacement when readings become drifty or inaccurate. Calibration is performed at one or two points at 0% using Hanna’s HI7040 solution or 100% in air. The HI2400 also provides users with GLP capabilities and PC connectivity via USB for a simple way to organize and manage their data.
    • Automatic Temperature Compensation
    • One or Two-Point Calibration
    • Interval Logging up to 8000 Samples
    Inquire Now

    Benchtop Conductivity Meter with ATC - HI2315

    1,486.00 AED
    The HI2315 is a durable benchtop meter that measures conductivity in four different ranges. The meter utilizes a four-ring potentiometric conductivity probe with platinum sensors to offer versatility over typical amperometric designs. By utilizing the four-ring probe, it is possible to measure very low or very high conductivity levels without having to change probes. The HI2315 also offers automatic temperature compensation and an adjustable temperature coefficient (β).
    • Four EC Measurement Ranges
    • Built-in Solution Holders
    • Automatic Temperature Compensation

    Water Conditioning Photometer - HI83308 (230V)

    2,358.00 AED
    HI83308 is a compact, multiparameter photometer for use in water conditioning applications. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include fluoride, chlorine, ammonia, manganese, copper, iron, silver and zinc.To save valuable laboratory benchtop space, the HI83308 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.Advanced optical systemUnparalleled performance from a benchtop photometerDigital pH electrode inputSave valuable bench space with one meter that works both as a photometer and as a laboratory pH meterAbsorbance measuring mode
    Back to Top
    Whatsapp
    Product has been added to your cart