Out of stock

Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe – HI6421P

HI6421P is a streamlined dissolved oxygen benchtop meter supplied with Hanna’s polarographic oxygen probe and features a large touch screen display for fresh and saltwater measurements.

systemUI

4,051.00 AED

Inquire Now
SKU:HI6421P-01

HI6421P is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen.

HI6421P includes the HI764833 polarographic probe. Slim and versatile, this probe covers a wide range of dissolved oxygen and has a built-in thermistor temperature sensor that compensates for temperature variations. The slim design allows for convenient measurement in test tubes and Biological Oxygen Demand (BOD) bottles.

Durable and robust, the probe features a platinum cathode and Ag/AgCl anode assembly. Accurate and with a fast response time, readings are not flow dependent.
The probe is fitted with durable (PTFE), oxygen permeable, screw on membrane caps. Caps are filled with electrolyte and easily installed on the probe.

Concentration measurements are automatically compensated for barometric pressure, temperature, and salinity. Barometric pressure and temperature are automatically measured and compensated. Salinity is automatically compensated by setting manually the salinity concentration of the water being measured.

Additional features include built-in methods and calculations for the measurement of BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Update Rate).

Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.

HI6421P

Features at-a-glance

User interface

  • 7-inch capacitive touch screen with multi-touch support
  • Capacitive touch back, home and system menu keys
  • User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions

The user can select between five different views:

  • Basic measurement configuration
  • Simple GLP with calibration information
  • Full GLP with electrode status and calibration point details
  • Live updated, interactive graph
  • Tabulated data with date, time, and notes

Measurement

  • Measure %Sat, mg/L, ppm (DO); mg/L, ppm (BOD); mg/L (OUR); ppm, mg/L (SOUR)
  • Application-specific profiles allow quick and direct measurement without the need to update the
    sensor and system settings
  • Active log during measurement Measurement stability indicator (using the Stability Criteria setting)
  • Reading modes: direct and direct/auto-hold
  • Temperature compensation can be Automatic or set manually
  • Audible and/or alarm messages for measurements outside of predefined limits
  • Galvanic isolation for measurement

Calibration

  • One or two points calibration at 0% and/or 100% saturation
  • Single point manual calibration in mg/L or % saturation using a reference method
  • Non-volatile memory saves data and settings

Logging

  • Data log collection of at least 1, 000, 000 data points (with time and date stamp)
  • Logging types: manual, automatic, auto-hold
  • Sample ID for manual and auto-hold data

Connectivity features & services

  • Transfer logged data ta USB thumb drive
  • Log files that include measurements and calibration data (as .csv file)
  • FTP and email for log export via Ethernet and Wi-Fi connection
  • USB type A for USB stick, keyboard, and printer
  • USB type C for USB stick and PC connection

Help section for meter guidance

  • Video support presentation of main functionalities

Primary Applications:

Fresh water and saltwater applications, aquaculture, aquariums, environmental.

Ordering Information:

HI6421P is supplied with HI764833 polarographic probe; HI764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.

Specifications

SKU HI6421P-01
Name Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe – HI6421P
DO (HI764833 Polarographic probe) Range 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0 % saturation
DO (HI764833 Polarographic probe) Resolution 0.01 mg/L (ppm); 0.1 % saturation
DO (HI764833 Polarographic probe) Accuracy ±1.5 % of reading ±1, least significant digit
Barometric Pressure Range 450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; / 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm
Barometric Pressure Resolution 1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm
Barometric Pressure Accuracy ±3 mmHg within ±15 % from the calibration point / ±3 mmHg ±1 least significant digit
Temperature Range −20.0 to 120.0 °C / −4.0 to 248.0 °F / 253.0 to 393.0 K
Temperature Resolution 0.1 °C; 0.1 °F; 0.1 K
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
DO Calibration Points Automatic-two points / User standard-single point
DO Calibration Standards 0 and 100% saturation
DO Calibration Reminder Disabled / Daily: 0 m in. to 23 hours and 59 m in. / Periodic: 1 m in. to 500 days, 23 hours and 59 m in.
Temperature Compensation Automatic or Manual
Reading Modes Direct Direct/Autohold
Reading Stability criteria Accurate Medium Fast
Reading Isopotential 7.000 or 4.010
Reading Sampling rate 1000 ms
DO Views Basic Measurement (DO, Temperature) Stability status
DO Views Simple GLP Basic view information Last calibration date, offset, average slope
DO Views Full GLP Simple GLP information and calibration point details
DO Views Table Measurements updated every second are displayed in table
DO Views Graph (Plot) Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology)
Logging Type Automatic, Manual, Autohold
Logging Number of records 50 000 maximum per file Stores at least 1 000 000 data points per user
Logging Automatic interval 1, 2, 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
Logging Sample ID Incremental mode
Logging Export option .csv file format
Users Up to 9 users and the default administrator account
Connectivity USB-A 2 ports for keyboard input or USB thumb drive
Connectivity USB-C 1 port for PC connectivity and USB-C type thumb drive
Connectivity Wi-Fi & Ethernet FTP / Web server Log transfer and download Email
Connectivity RS232 Connecting peripherals
Power supply DC adapter 100-240AC to 24VDC 2.5A
Environment 0 – 50 °C / 32 – 122 °F / 273 – 323 K maximum 95% RH non-condensing
Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
Weight Approximately 1.2 kg (26.5 lbs.)

Manuals

Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe – HI6421P

Bestsellers

Inquire Now

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

edge® Wine pH Meter (kit) - HI2020W

edge® digital pH meter for wine kit delivers precision while offering simplicity and versatility in a sleek design. Upgrade to the Hanna edge® wine pH kit for professional winemakers. The HI2020W allows you to add a conductivity probe and a dissolved oxygen probe to give you full versatility. Fast results, ultra-accurate, hassle-free analysis.
  • Complete meter kit for measuring pH in wine.
  • CAL Check™ feature ensures the accuracy of the meter.
  • Great for professional and home winemakers.

Advanced Conductivity Benchtop Meter - HI6321-02 (230V)

3,839.00 AED
HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.
Inquire Now

edge® Multiparameter pH Meter - HI2020

1,795.00 AED
edge® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with a simplified menu and options. For those who require advanced features there is the full featured standard operating mode. The edge HI2020 pH kit can be upgraded at any time with additional probes to measure Conductivity or Dissolved Oxygen.
Inquire Now

Iron (Low Range) Test Kit Replacement Reagents (100 tests) - HI38039-100

82.00 AED
The HI38039-100 are replacement reagents for the colorimetric determination of iron with the HI38039 Iron Low Range Test Kit. There are enough reagents for approximately 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Marine Master Waterproof Wireless Multiparameter Photometer - Kit | HI97115C

pH, Alkalinity, Ammonia, Calcium, Magnesium,Nitrate Low Range, Nitrate High Range, NitriteUltra Low Range, Phosphate Ultra Low RangeThe HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.
Inquire Now

ISO 7027 Compliant Benchtop Turbidity Meter - HI88713 (230V)

7,384.00 AED
The HI88713 is a high accuracy benchtop turbidity meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI88713 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements.
  • Compliant to ISO 7027 method
  • Ratio and non-ratio turbidity modes
  • USB for data transfer
Back to Top
Whatsapp
Product has been added to your cart