ISO 7027 Compliant Benchtop Turbidity Meter – HI88713 (230V)

The HI88713 is a high accuracy benchtop turbidity meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI88713 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements.

  • Compliant to ISO 7027 method
  • Ratio and non-ratio turbidity modes
  • USB for data transfer

6,966 AED

Estimated delivery: 10 - 11 December

Inquire Now
SKU:HI88713-02

The HI88713 Precision ISO Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

Features at-a-glance:

Four Measurement Modes – The HI88713 features four options for turbidity measurement: FNU (Formazin Nephelometric Units), FAU (Formazin Attenuation Units), and NTU (Nephelometric Turbidity Units) ratio and non-ratio mode. Turbidity ranges for each mode are 0.00 to 1000 FNU, 10.0 to 4000 FAU, 0.00 to 4000 NTU (ratio mode), and 0.00 to 1000 NTU (non-ratio mode).

Multiple Turbidity Units of Measure – Turbidity can be read as Formazin Nephelometric Units (FNU), Formazin Attenuation Units (FAU), European Brewing Convention units (EBC), and Nephelometric Turbidity Units (NTU).

ISO Compliant – The HI88713 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source.

Calibration – The HI88713 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, four, or five-point turbidity calibration can be performed by using the supplied (<0.10, 15, 100, 750 FNU, and 2000 NTU) standards. Calibration points can be modified if user-prepared standards are used.

AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

GLP Data – The HI88713 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the USB port and the HI92000 software.

Tutorial Mode – The unique tutorial mode provides additional information to help the user during measurements. When enabled, the instrument displays explanations and a confirmation button when a preparation or other operation has to be performed.

Contextual Help – Contextual help is always available through a dedicated HELP button. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Backlit Graphic LCD Display – A graphic LCD display provides an easy to understand, user-friendly interface. All messages are in plain text making them easy to read.


Turbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.

Turbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity, the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree, as no solution will have zero turbidity.

The ISO standard for turbidity measurement uses infrared wavelength of light that is outside the visible spectrum. The primary benefit of the ISO method over the EPA method is the reduction of color interference. The EPA method uses a tungsten lamp that produces light that contains all of the visible wavelengths of light that we see as white. A solution that is colored will be adsorbed by a complementary wavelength of light which will affect the turbidity reading. Since the ISO method is outside the visible wavelength of light the color in the sample does not interfere with the measurement. The USEPA prefers the tungsten lamp since it provides for better accuracy at low ranges and drinking water should not be colored. The requirements of an optical turbidity meter according to ISO 7027 are dependent on the measurement range. The measurement of diffuse radiation is typically for low range turbidity measurements (i.e. drinking water) with measurements expressed as formazin nephelometric units (FNU). The measurement of attenuation of radiant flux is for highly turbid samples (i.e. polluted water) and the measurements are expressed as formazin attenuation units (FAU). The design criteria for each method are:

Measurement of diffuse radiation for water with low turbidity (0 FNU to 40 FNU)

  • The wavelength of the incident radiation shall be 860 nm
  • The spectral bandwidth of the incident radiation shall be less than or equal to 60 nm
  • There shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 1.5o.
  • The measuring angle, theta, between the optical axis of the incident radiation and that of the diffused radiation shall be 90o ±2.5o.
  • The aperture angle should be between 20o and 30o in the water sample.

Measurement of attenuation of radiant flux for highly turbidity (40 FAU to 4000 FAU)

  • The wavelength of the incident radiation shall be 860 nm
  • The spectral bandwidth of the incident radiation shall be less than or equal to 60 nm
  • There shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 2.5o.
  • The measuring angle of the incident radiation and that of the diffuse radiation shall be 0o ±2.5o.
  • The aperture angle should be between 10o and 20o in the water sample.

The HI88713 meets and exceeds the meter criteria speci˜ed by ISO 7027.

Principal of Operation

The light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is affected by many variables, such as wavelength of the incident light, particle size and shape, refractive index, and color. The optical system of the HI88713 includes a LED, a scattered light detector (90°) and a transmitted light detector (180°). Which detectors are used are based on the measurement mode.

In the non-ratio turbidimeter range, the NTU and FNU values are calculated from the signal on the scattered light detector (90°).

In FAU mode the turbidity is calculated from the signal that reaches the transmitted light detector.

In the ratio turbidimeter range, the microprocessor of the instrument calculates the NTU value from both the scattered and transmitted light detectors. An effective algorithm is used to correct and compensate for interferences of color.

The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI88713 is designed to have very low stray light, providing highly accurate results for low turbidity samples.

Turbidity meter light path

reagents

The HI88713-11 AMCO AEPA-1 standards ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the turbidity meter.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable
Provided storage containers

  • Light tight
  • Protects from accidental breakage

Specifications

SKU HI88713-02
Name ISO 7027 Compliant Benchtop Turbidity Meter – HI88713
Turbidity Range FNU mode: 0.00 to 9.99 FNU, 10.0 to 99.9 FNU, 100 to 1000 FNU
FAU mode: 10.0 to 99.9 FAU, 100 to 4000 FAU
Non-Ratio mode: 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1000 NTU 0.00 to 9.99 EBC; 10.0 to 99.9 EBC; 100 to 245 EBC
Ratio mode: 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 4000 NTU 0.00 to 9.99 EBC; 10.0 to 99.9 EBC; 100 to 980 EBC
Turbidity Resolution FNU mode: 0.01 FNU, 0.1 FNU, 1 FNU
FAU mode: 0.1 FAU, 1 FAU
Non-Ratio mode: 0.01; 0.1; 1 NTU; 0.01; 0.1; 1 EBC
Ratio mode: 0.01; 0.1; 1 NTU; 0.01; 0.1; 1 EBC.
Turbidity Accuracy FNU mode: ±2% of reading plus stray light
FAU mode: ± 10% of reading
Non-Ratio mode: ±2% of reading plus stray light
Ratio mode: ±2% of reading plus stray light, ±5% of reading above 1000 NTU.
Turbidity Repeatability ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater
Turbidity Stray Light < 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Turbidity Calibration two, three, four, or five-point calibration
Turbidity Measuring Method nephelometric method (90°) or ratio nephelometric method (90° & 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Turbidity Measuring Modes normal, average, continuous
Turbidity Light Source IR LED
Turbidity Light Detector silicon photocell
Logging Memory 200 records
Connectivity USB
Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 230 x 200 x 145 mm (9.0 x 7.9 x 5.7 in.)
Weight 2.5 kg (88 oz.)

Ordering Info

HI88713 is supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, cuvette wiping cloth, power adapter, and instruction manual.

Manuals

ISO 7027 Compliant Benchtop Turbidity Meter – HI88713

Bestsellers

Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

481 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

Digital Glass Body pH Electrode for General Purpose - HI11310

601 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

HI7004L pH 4.01 Calibration Solution (500 mL)

55 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Inquire Now

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

2,530 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

HALO® Bluetooth® Wireless pH Meter for Flat Surfaces - HI14142

932 AED
The HI14142 HALO is an innovative pH electrode with Bluetooth® Smart technology designed for flat surfaces Our HALO® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edge®blu.One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology.Status Indicator Visible from a distance, the LED “halo” light flashes to indicate the status of the probe.Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Back to Top
Whatsapp
Product has been added to your cart