“HI7007/1L pH 7.01 Calibration Solution (1 L)” has been added to your cart. Continue shopping
Showing 157–168 of 281 resultsSorted by popularity
Desiccant Cartridge for Titrant or Vessel for HI903 - HI900532
228.00 AED
The HI900532 is a glass desiccant cartridge with cover designed to fit the titrant bottle or titration vessel enclosures for the HI903 Karl Fischer Titration System.Each cartridge comes sealed and filled with dry silica gel desiccant ready for immediate use upon opening. The rechargeable, color-indicating silica gel prevents the ingress of ambient humidity in the sealed system. It’s color change allows the user to recognize when it’s adsorption capacity has been depleted.
- Color indicating desiccant
- Quick replacement
- Easy to assemble
HI7071 Electrolyte Fill Solution, 3.5M KCl + AgCl (30 mL x 4)
265.00 AED
HI7071 is a pH and ORP electrode fill solution that contains 3.5M KCl + AgCl, which is specifically made for single junction electrodes. The electrolyte level in refillable electrodes should be checked before performing any measurements. If the level is low, refill with the proper electrolyte solution to ensure optimum performance. This simple maintenance helps guarantee adequate head pressure to promote the flow of reference electrolyte into the sample being measured.
- Fill solution for single junction pH & ORP electrodes
- Convenient 30 mL bottles
- Clearly marked bottle with expiration date and lot number
Phosphorus High-Range Checker® Reagents (25 Tests) - HI706-25
36.00 AED
The HI706-25 are the replacement reagents for the HI706 Phosphorus High-Range Checker® HC. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
- Pre-made reagents for ease of use
- Prepared with high-purity chemicals
- Marked with expiration date and lot number for traceability
HI7041L Dissolved Oxygen Electrolyte Solution (500 mL)
279.00 AED
The HI7041L electrolyte fill solution has been developed for Hanna’s polarographic dissolved oxygen probes. Having the correct electrolyte solution is crucial to the performance of your dissolved oxygen probe.
- Made with reagent grade chemicals
- Long-lasting supply of electrolyte
5, 000 µS/cm Conductivity Standard (1 L bottle) – HI7039/1L
77.00 AED
HI7039/1L is a 5, 000 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
- Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
- Air tight bottle with tamper-proof seal to ensure quality
111, 800 µS/cm Conductivity Standard (1 L) – HI7035/1L
77.00 AED
HI7035/1L is a premium quality 111, 800 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
- Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
- Air tight bottle with tamper-proof seal to ensure quality
80, 000 µS/cm Conductivity Standard (1 L) – HI7034/1L
77.00 AED
HI7034/1L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against an NIST traceable potassium chloride solution. Hanna conductivity solutions are airtight with a tamperproof seal to ensure the quality of the solution. Each bottle is clearly marked with the lot number and expiration date. Hanna's line of conductivity standards is specially formulated to be valid for 5 years from the date of manufacture for an unopened bottle.
- Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
- Air tight bottle with tamper-proof seal to ensure quality
HI7033M 84 µS/cm Conductivity Standard (230mL Bottle)
54.00 AED
HI7033M is a premium quality 84 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 3 years from the date of manufacture for an unopened bottle.
- Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
- Air tight bottle with tamper-proof seal to ensure quality
HI70300M Electrode Storage Solution (230 mL)
54.00 AED
HI70300M is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any diffusion/osmotic effects from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300M storage solution for at least one hour before taking measurements.
- Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
- Clearly marked expiration date and lot number
HI7010/1G pH 10.01 Calibration Solution (1 G ( 3.78 L) )
200.00 AED
HI7010/1G is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
HI7007/1G pH 7.01 Calibration Solution (1 G ( 3.78 L))
200.00 AED
HI7007/1G is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
- Air-tight Seal
HI7004/1G pH 4.01 Calibration Solution (1 G ( 3.78 L))
200.00 AED
HI7004/1G is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
- Air-tight Seal