Out of stock

Waterproof Thermistor Thermometer – HI93510

The Waterproof Thermistor Thermometer – HI93510 is housed in a rugged waterproof casing designed for use in the field as well as the laboratory. The HI93510 offers a wide range of probes for measurement in gases, air, and liquids, as well as surfaces and substances that require penetration for accurate readings. Optional thermistor probes cover a wide temperature range from -50.0 to 150℃ (-58.0 to 302℉).

  • ±0.4℃ (±0.8℉) Accuracy
  • High and low-temperature display
  • Thermistor Probes

638.00 AED

Inquire Now
SKU:HI93510

The Waterproof Thermistor Thermometer – HI93510 is a rugged meter that can be used indoors or outdoors with a wide variety of thermistor probes. The HI93510 offers features such as a selection of Celsius or Fahrenheit units, hold function, low and high reading display, and Hanna’s Battery Error Prevention System (BEPS) that will shut the meter off when the battery power is too low for an accurate measurement.

Features at-a-glance

℃/℉ Readout – Measurements can be displayed in either degrees Celsius or Fahrenheit. A simple press of the ℃/℉ button will switch between the two scales.

Interchangeable ThermistorProbes – A wide range of thermistor type probes are available to meet the specific needs of users. Hanna Instruments offers the HI762 series that includes probes to measure the temperatures of surfaces, gases, air, liquid, and semisolid samples.

High/Low Function – The maximum and minimum temperature values are continuously displayed along with current reading on the LCD display. To reset the high/low readings the “CLEAR” button is used.

HOLD Function – The HOLD button on the face of the meter freezes the display to allow the user time to record readings. Although the display is frozen, the meter continues to internally monitor the temperature and update the high and low measurement values.

Optional Calibration Test Keys – For measurements that are always reliable, thermometers must be calibrated periodically. Hanna offers calibration test keys (not included) to offer a fast and simple way of checking the accuracy of the HI93510. By simply connecting the key to the probe input, the thermistor thermometer will display a reading; if the reading differs more than 0.4℃ (0.8℉) from the key value, the thermometer should be recalibrated.

Automatic Shut-off – The HI93510 has a selectable automatic shut-off feature. The meter can be set to turn off after 8 minutes, 60 minutes, or disabled.

Battery Error Prevention System (BEPS) – The Battery Error Prevention System will shut the meter off when the battery power is too low for an accurate measurement.

Low Battery Indicator – When the battery level is below 10%, a warning symbol will blink to indicate low battery condition.

Specifications

SKU HI93510
Name Waterproof Thermistor Thermometer – HI93510
Thermistor Temperature Range -50.0 to 150.0°C; -58.0 to 302.0°F
Thermistor Temperature Resolution -50.0 to 150.0°C; -58.0 to 302.0°F
Thermistor Temperature Accuracy ±0.4°C; ±0.8°F (for 1 year, excluding probe error)
Temperature Probe HI762BL air/liquid, stainless steel thermistor temperature probe with black handle and 1 m (3.3’) cable (included)
Automatic Shut-Off 8 min (default), 60 min or OFF
Battery Type/Life 1.5V AA (3) / approximately 2000 hours of continuous use (with backlight off)
Environment -10 to 50°C (14 to 122°F); RH max 100%
Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight 235 g (8.3 oz)

Ordering Info

HI93510 is supplied with HI762BL temperature probe, batteries, and instruction manual.

Manuals

Waterproof Thermistor Thermometer – HI93510

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart