Out of stock

Wall Mounted EC Digital Controller HI23211

HI2321 is a wall mounted, microprocessor conductivity controller specifically designed to meet your process control requirements. This controller provides very accurate measurements due to the four-ring EC probe and Automatic Temperature Compensation (ATC) feature.

  • Fail Safe Alarm System.
  • CAL Check™ alerts users of calibration status.
  • Four-ring method provides an exceptionally stable measurement over a wider range.

3,858.00 AED

Inquire Now
SKU:HI23211-1

Fail Safe Alarm System

  • Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Simple Installation

  • HI22111 has mounting holes molded into the housing to assure simple, quick and secure installation without the need for additional hardware.

Isolated Recorder Output

  • To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.

Good Laboratory Practices (GLP)

  • The GLP feature allows users to store and recall data about system status for ultimate traceability.

Quality Construction

  • Housed in a rugged, modular, fiber-reinforced polypropylene housing that will resist the harmful effects of most chemicals.

Password Protection

  • The Hanna password protection feature keeps these controllers safe from tampering. Only users with the proper password can change the settings of these controllers.

Specifications

SKU HI23211-1
Name Wall Mounted EC Digital Controller HI23211
EC Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
EC Resolution 0.1 µS/cm, 1 µS/cm; 0.01 mS/cm, 0.1 mS/cm
EC Accuracy 0.5% f.s.
EC Calibration automatic, 1 point
EC/TDS Temperature Compensation automatic or manual from -10 to 100°C with Pt100 probe; β adjustable from 0.00 to 10.00%/°C
Temperature Range 10.0 to 100.0°C
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5 °C (0 to 70°C); ±1 °C (outside)
Consent Relay electromechanical relay SPDT contact outputs, 5A-250 VAC, 5A – 30 VDC (resistive load) (HI211YZ and HI212YZ), fuse protected: 5A, 250V fast fuse
Alarm Relay Set Point electromechanical relay SPDT contact output, 5A – 250 VAC, 5A – 30 VDC (resistive load) fuse protected: 5A, 250V, 250V fast fuse
Analog Ouput Signal 0-10 VDC, 0-5 VDC or 1-5 VDC; 0-1mA, 0-20 mA or 4-20mA
Digital Output Signal RS485
Baud Rate RS 485 baud rate 1200, 2400, 4800 and 9600
Power Consumption 15 VA
Over Current Protection 400 mA, 250V, fast fuse
Enclosure Fiber-reinforced, self-extinguishing ABS
Installation Category II
EC/TDS Probe four-ring conductivity probe with built-in 3-wire Pt100 temperature sensor or conductivity probe + external Pt100 (not included)
Display LCD
Power Supply 115 ±10% VAC
Environment 0-50 °C; RH max 85% non-condensing
IP Rating IP54
Dimensions 221 x 181 x 86 mm (8.7 x 7.1 x 3.4”)
Weight 1.6 kg (3.5 lb.)

Ordering Info

Supplied with instructions.

Manuals

Wall Mounted EC Digital Controller HI23211

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart