In stock

Ultra Pure Water (UPW) Tester (0.000-1.999 µS/cm) – HI98309

The HI98309 UPW is the first pure water tester/conductivity meter to measure in 1/1000ths of micro-Siemens and provides on-the-spot and fast checks for minute traces of contamination in your water, assuring high quality of finished products in processes. A rugged, pocket-sized tester that features graphite electrodes to reduce polarization effects. The HI98309 comes already calibrated, done with freshly prepared low-conductivity solutions in factory due to the high instability of calibration solutions in the UPW range (below 2 µS/cm).

  • Exposed temperature sensor for fast response
  • Accurate readings of ultra low range 0.000 to 1.999 µS/cm
  • Factory calibrated
  • 263 AED

    Estimated delivery: 20 - 21 May

    SKU:HI98309

    The HI98309 uses a conductometric measurement to determine the purity of water. The HI98309 Ultra Pure Water tester (UPW) enables users to check the purity of water, best suited for electronics and semiconductor industries. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.

    The HI98309 features an amperometric graphite electrode that provides better repeatability in measurements, since they do not oxidize. An amperometric measurement of EC is based on Ohm’s Law, I = V/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.

    Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration however it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-. This is a simplified definition for the measurement is affected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.

    Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.

    Features at-a-glance:

    Arrives pre-calibrated

    • Factory-calibrated with freshly prepared low-conductivity solutions

    Exposed Temperature Probe

    • Fast response to changes in sample temperature

    Graphite electrode

    • Reduced polarization effects

    Specifications

    SKU HI98309
    Name Ultra Pure Water (UPW) Tester (0.000-1.999 µS/cm) – HI98309
    EC Range 0.000 to 1.999 µS/cm
    EC Resolution 0.001 µS/cm
    EC Accuracy ±2% F.S.
    EC Calibration Factory calibrated
    Battery Type/Life 1.5V (4) / approximately 200 hours of continuous use
    Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions 175 x 41 x 23 mm (6.9 x 1.6 x 0.9”)
    Weight 95 g (3.4 oz.)

    Ordering Info

    HI98309 is supplied with protective cap, batteries and instructions.

    Manuals

    Ultra Pure Water (UPW) Tester (0.000-1.999 µS/cm) – HI98309

    Bestsellers

    pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

    463 AED
    The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
    • Pre-amplified pH Electrode
    • Amperometric EC/TDS Sensor
    • CAL Check Compatible

    pH/EC/TDS Multiparameter Probe - HI1285-51

    463 AED
    The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
    • Pre-amplified pH electrode
    • Amperometric EC/TDS sensor
    • Built-in temperature sensor

    Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

    597 AED
    The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
    • Waterproof
    • Replaceable pH electrode with extractable junction
    • Automatic calibration

    GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

    663 AED
    The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
    • 3 parameters, pH, EC/TDS and temperature, in one meter
    • Quick Cal Mode to calibrate pH and EC/TDS with one solution
    • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

    HI7007L pH 7.01 Calibration Solution (500 mL)

    55 AED
    HI7007L is a premium quality pH 7.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
    • Color coded label for easy pH buffer value identification
    • Accuracy of ±0.01 pH @ 25℃
    • Temperature chart of the actual pH value at various temperatures printed on each bottle

    COD Low Range Reagent Vials, ISO Method (25 tests) - HI93754F-25

    236 AED
    The HI93754F-25 are reagent vials that follow the ISO approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
    • Pre-dosed reagents for ease of use
    • Supplied with certificate of quality
    • Marked with expiration date and lot number for traceability

    Digital Refractometer for Ethylene Glycol Analysis - HI96831

    819 AED
    The HI96831 is a rugged, portable digital refractometer designed for the measurement of percent volume and freezing point of ethylene glycol based solutions. The HI96831 has a high accuracy of ±0.2% volume and ±0.5 ℃ freezing point and features simple operation that gives reliable results each and every time. All readings are automatically compensated for temperature variations and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
    • Sample size as small as 2 metric drops (100 µl)
    • Sealed stainless steel well with high-grade optical prism made of flint glass
    • Fast 1.5 second response time for temperature compensated readings
    Back to Top