The HI93767A-50 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the chromotropic acid method in which a digestion is required to convert all forms of nitrogen to nitrate. Sodium metabisulfite is added to remove potential interferences. The reaction between nitrate and the reagents causes a yellow tint in the sample. The intensity of color is determined by a compatible photometer and the concentration will be displayed in mg/L (ppm) as total nitrogen. These reagents are designed to be used with samples that have an expected range of 0.0 to 25.0 mg/L (ppm) nitrogen.
Out of stock
Total Nitrogen Low Range Reagents (50 tests) – HI93767A-50
The HI93767A-50 are reagents for the low range colorimetric determination of total nitrogen. There are enough reagents for 50 tests to be used with a compatible photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
- Pre-made reagents for ease of use
- Supplied with certificate of quality
- Marked with expiration date and lot number for traceability
479 AED
Estimated delivery: 9 - 10 November
SKU:HI93767A-50
Specifications
SKU | HI93767A-50 |
Name | Total Nitrogen Low Range Reagents (50 tests) – HI93767A-50 |
Package | Packets and bottle |
Quantity | 50 tests |
Method | chromotropic acid method |
Bestsellers
Inquire Now
Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301
481 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.
The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.
The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
- Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
- Double Junction Reference
- 3.5 mm Connector
pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7
463 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
- Pre-amplified pH Electrode
- Amperometric EC/TDS Sensor
- CAL Check Compatible
pH/EC/TDS Multiparameter Probe - HI1285-51
463 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples.The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
- Pre-amplified pH electrode
- Amperometric EC/TDS sensor
- Built-in temperature sensor
HI7004L pH 4.01 Calibration Solution (500 mL)
55 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
Foodcare pH Electrode for Semi-Solid with Quick Connect DIN Connector - FC2023
743 AED
The FC2023 is an amplified double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190.
The FC2023 electrode features a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration is ideal for pH measurements in dairy products, emulsions, cream, or other semi-solid samples. The recommended operating temperature range is from 0 to 50℃.
- Low Temperature Glass
- PVDF Body
- Open Junction
GroLine pH 10.01 Calibration Buffer (500 mL) - HI7010-050
55 AED
HI7010-050 is a high quality pH 10.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and have an air tight, tamper-proof seal to ensure the quality of the solution. This technical calibration buffers has been specially formulated with expiration 2 years from the date of manufacture for an unopened bottle.
- Supplied with Certificate of Analysis
- Accuracy of ±0.02 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
Inquire Now
pH/EC/TDS Multiparameter Probe - HI1285-5
463 AED
The HI1285-5 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-5 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-5 is designed for use with Hanna’s HI9813-5, HI9812-5, and HI9811-5 portable multiparameter meters.
- Pre-amplified pH electrode
- Amperometric EC/TDS sensor
- Built-in temperature sensor