Out of stock
Total Hardness EPA Portable Photometer – HI96735
The HI96735 is no longer available.
Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.
Both meters use the same reagents.
908.00 AED
Inquire NowThe HI96735 portable photometer is for the measurement of total hardness. Hanna’s portable photometers feature an advanced optical system; the combination of a light emitting diode (LED), a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
*Reagents ordered separately

CAL Check™ standards with certificate
The HI96735-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function.
Supplied with Certificate of Analysis
- Lot number
- Expiration date
- Standard value @ 25 ℃
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage

Specifications
| SKU | HI96735-web |
| Name | Total Hardness EPA Portable Photometer – HI96735 |
| Hardness, Total Range | Hardness LR: 0 to 250 mg/L; Hardness MR: 200 to 500 mg/L; Hardness HR: 400 to 750 mg/L (ppm) CaCO₃ |
| Hardness, Total Resolution | 1 mg/L from 0 to 100 mg/L, 5 mg/L from 100 to 750 mg/L (ppm) CaCO₃ |
| Hardness, Total Accuracy | Hardness LR: ±5 mg/L ±4% of reading; Hardness MR: ±7 mg/L ±3% of reading; Hardness HR: ±10 mg/L ±2% of reading |
| Hardness, Total Method | adaptation of the EPA recommended method 130.1 |
| Photometer/Colorimeter Light Source | light emitting diode |
| Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 466 nm |
| Battery Type/Life | 9V battery |
| Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Weight | 9V battery |
| Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Info
HI96735 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. *CAL Check™ standards and testing reagents sold separately.