Out of stock

Total Hardness and Iron Low-Range Portable Photometer with CAL Check – HI97741

HI97741 is an advanced portable photometer for the measurement of total hardness and iron in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

Estimated delivery: 24 - 25 April

Inquire Now
SKU:HI97741-

In domestic water, iron can alter taste, making it unpleasant to drink. It can also stain laundry, damage kitchenware, and favor the growth of certain bacteria. However, low levels of iron are critical in beverage production. The iron concentration in water needs to be monitored since it can become harmful above certain levels.

In domestic water, iron can alter taste, making it unpleasant to drink. It can also stain laundry, damage kitchenware, and favor the growth of certain bacteria. However, low levels of iron are critical in beverage production. The iron concentration in water needs to be monitored since it can become harmful above certain levels.

The HI97741 offers two methods within one meter. Total hardness uses an adaptation of the colorimetric method; low range iron uses an adaptation of the TPTZ method.

When the appropriate reagent is added to the sample, it will display a color change; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For determination of total hardness and iron, a narrow band interference filter at 525 nm allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the LED. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

The HI97741 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LCD allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences.

HI97741 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortably in the hand for use in the field or on a table for benchtop use. The LCD is backlit for easy viewing under all conditions.

photometer optical system
  • LED that generates very little heat
  • 8 nm narrowband interference filter that is accurate to ±1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output. 
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

On-Screen Features

Certificate

CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.

Setup

Setup Options
Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.

Chemical forms

Multiple Chemcial Forms
Display hardenss results in choice of chemcial forms.

Measure

Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

Reaction

Reaction Timer
Built-in reaction timer that ensures consistency amongst multiple users.

HI97741 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97741 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. 

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Large Cuvette Size:

  • The sample cell of the HI97741 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97741 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Specifications

SKU HI97741-web
Name Total Hardness and Iron Low-Range Portable Photometer with CAL Check – HI97741
Hardness, Total Range 0.00 to 4.70 mg/L (as CaCO3)
Hardness, Total Resolution 0.01 mg/L
Hardness, Total Accuracy ±0.11 mg/L ±5% of reading at 25°C
Hardness, Total Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 23rd Edition, Colorimetric Method
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading at 25°C
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 23rd Edition, Colorimetric Method
Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading at 25°C
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 23rd Edition, Colorimetric Method
Iron Range 0.00 to 1.60 mg/L (as Fe)
Iron Resolution 0.01 mg/L
Iron Accuracy 0.01 mg/L ±8% of reading at 25°C
Iron Method Adaptation of the TPTZ Method
Photometer/Colorimeter Light Source LED with 525 nm bandpass filter
Photometer/Colorimeter Light Detector silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round 24.6 mm diameter (22 mm inside)
GLP yes
Display 128 x 64 pixel B/W LCD with backlight
Logging Memory 50 readings
Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67)
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)

Ordering Info

HI97741C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.
HI97741 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.

Manuals

Total Hardness and Iron Low-Range Portable Photometer with CAL Check – HI97741

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal
Back to Top
Whatsapp
Product has been added to your cart