In stock

Portable High Range EC/TDS Meter – HI99301

The HI99301 is a rugged, portable EC/TDS and temperature meter housed in a case rated for IP67 conditions. It is supplied with a two-ting conductivity probe to allow for high range EC measurements from 0.00 to 20.00 mS/cm and TDS measurements from 0.00 to 10.00 ppt. All readings are adjusted with Automatic Temperature Compensation (ATC) and users are able to adjust the temperature correction coefficient and TDS factor for accurately compensated measurements.

  • One-point Automatic Calibration
  • Adjustable TDS factor
  • Automatic Temperature Compensation

765 AED

Estimated delivery: 15 - 16 May

SKU:HI99301

The portable, waterproof HI99301 EC/TDS and temperature meter is suitable for use in applications as diverse as wastewater treatment, reverse osmosis, and HVAC. It measures high range conductivity in mS/cm and TDS in ppt. The HI763063 EC/TDS probe is a twO-ring sensor that resists clogging and is easy to clean. The probe also features a built-in temperature sensor to allow for Automatic Temperature Compensation from 0 to 60℃ (32 to 140℉).

The meter easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in the way. The large, multi-level LCD displays the primary reading, temperature, and calibration guides simultaneously. Symbols and messages on the LCD indicate meter status and guides users through operations.

Features at-a-glance

Two-Ring Probe – The HI763063 is a two-pole probe that comes with the HI99301, offering an accurate solution for high range EC and TDS readings. The probe features a built-in temperature probe to allow for temperature compensated readings.

Two Measurement Modes – HI99301 offers two measurement modes: EC and TDS. Users can easily switch between measurement modes with a simple press of the MODE button. EC measurements range from 0.00 to 20.00 mS/cm; TDS measurements range from 0.00 to 10.00 ppt.

Adjustable TDS Factor – The TDS value in aqueous solutions is directly proportional to conductivity. The ratio between the two parameters depends on the solution being measured. The HI99301 has an adjustable TDS factor from 0.45 to 1.00 with 0.01 intervals, allowing users to choose the conversion factor that is the most appropriate for their particular solution.

Automatic Temperature Compensation – Since temperature has such a dramatic effect on conductivity and TDS readings, having a meter that offers temperature compensated readings is invaluable. The probe of the HI99301 features a built-in temperature sensor that automatically accounts for the effects of temperature in the range of 0 to 60℃ (32 to 140℉).

Adjustable Temperature Compensation Coefficient – The temperature compensation coefficient, also known as β, is adjustable from 0.0 to 2.4%/℃ with 0.1% intervals; this factor corrects the reading a set percentage % for each degree Celsius change in the sample.

Automatic Calibration – The HI99301 can be automatically calibrated at one point in a standard EC or TDS solution. A 12.88 mS/cm standard is used for EC calibration, which will automatically calibrate TDS readings. However, if the meter is in TDS mode and set to 0.5 conversion factor, a direct calibration in 6.44 ppt TDS calibration solution can be used.

Battery Error Prevention System (BEPS) – The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.

Instability Indicator – The HI99301 displays a clock tag that will disappear when a reading has achieved stability.

Specifications

SKU HI99301
Name Portable High Range EC/TDS Meter – HI99301
EC Range 0.00 to 20.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% FS
EC Calibration automatic, single point at 12.88 mS/cm
TDS Range 0.00 to 10.00 ppt (g/L)
TDS Resolution 0.01 ppt (g/L)
TDS Accuracy ±2% F.S.
TDS Calibration automatic
EC/TDS Temperature Compensation automatic, 0 to 60°C (32 to 140°F)
Temperature Correction Coefficient automatic, with b selectable from 0.0 to 2.4 %/ °C in 0.1 increments
EC to TDS Conversion Factor Selectable from 0.45 to 1.00 (CONV) in 0.01 increments
Temperature Range ‐5.0 to 105.0 °C / 23.0 to 221.0 °F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C /±1°F
EC/TDS Probe HI763063 with built-in temperature sensor, quick connect DIN connector and 1 m cable (included)
Automatic Shut-Off user selectable: after 8 min, 60 min or disabled
Battery Type/Life 1.5V AAA (3) / approximately 500 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH 100%
Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)
Weight 196 g (6.91 oz.)

Ordering Info

HI99301 is supplied with HI763063 EC/TDS probe, HI70030 12880 µS/cm calibration solution sachet (1), HI70038 6.44 ppt calibration solution sachet (1), batteries, calibration certificates for both meter and probe, instruction manual, and rugged thermoformed carrying case.

Manuals

Portable High Range EC/TDS Meter – HI99301

Bestsellers

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

463 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible

pH/EC/TDS Multiparameter Probe - HI1285-51

463 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

597 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7010L pH 10.01 Calibration Solution (500 mL)

55 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Honey Color Portable Photometer - HI96785

1,362 AED
The HI96785 Honey Color Portable Photometer is used to measure the transmittance of light in order to determine the color of honey. The HI96785 combines accuracy and ease of use in an ergonomic, portable design that ends the days of judging color by “eye”. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time.
  • Calibrates 100% transmittance with a glycerol standard
  • Auto-shut off
  • Digital color analysis of honey from 0-150 mm Pfund

Chlorine Ultra High Range Checker® HC Reagents (25 Tests) - HI771-25

55 AED
The HI771-25 are the replacement reagents for the HI771 Total Chlorine Ultra High Range Checker® HC. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Back to Top