In Stock

Pool Line pH and mV Precision Simulator – HI9310014

HI9310014 is a portable pH/mV simulator designed specifically for testing pH and mV (ORP) meters. It’s a great diagnostic tool to test pH/mV meters including process controllers. Connecting the HI9310014 to your meter’s input socket, readings can be simulated for a range of measurements.

  • Simulates from 0 to 14 pH and from -1000 to 1000 mV
  • Works on all meters with a BNC connector
  • Invaluable diagnostic tool for Service and Maintenance Personnel

1,062.00 AED

Estimated delivery: 10 - 11 April

SKU:HI9310014

Features

Signal outputs are derived using the the Nernst equation

Connects to any voltmeter that uses a BNC connector

Manually set the temperature compensation of the meter

Low battery indicator

Specifications

SKU HI931-01
Name Automatic Potentiometric Titrator – HI931
mV Range -2000.0 to 2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.1 mV
mV Calibration single point offset
pH Range -2.000 to 20.000 pH; -2.00 to 20.00 pH; -2.0 to 20.0 pH
pH Resolution 0.001 pH; 0.01 pH; 0.1 pH
pH Accuracy ±0.001 pH
pH Calibration up to five-point calibration, eight standard buffers and five custom buffers
pH Temperature Compensation automatic from -5.0 to 105.0°C; 23.0 to 221.0°F
ISE Range 1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration
ISE Resolution 1; 0.1; 0.01 concentration
ISE Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration automatic, up to five point calibration, seven fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration) and five custom solutions
Temperature Range -5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K
Temperature Resolution 0.1°C; 0.1°F; 0.1K
Temperature Accuracy ±0.1°C; ±0.2°F; ±0.1K, excluding probe error
Potentiometric Titrations acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric
Analog Boards Capability one analog board for pH/ORP/ISE; not upgradeable
Measurement Units user-specified expression of concentration units to suit specific calculation requirements
Endpoint Criteria single equivalence point (1st or 2nd derivative) or fixed pH/mV value
Dosing Pump Capability one included can be upgraded for two
Flow Rate user-selectable from 0.1 mL/min to 2 x burette volume/min
Dosing Accuracy ±0.1% of full burette volume
Burette one 25 mL burette included
Burette Size Capability 5, 10, 25, and 50 mL (auto-detection)
Dosing Pump Resolution 1/40000
Stirrer Type overhead propeller type, 200 to 2500 rpm, resolution 100 rpm
Titrator Methods up to 100 methods (standard and user-defined)
Linked Methods not available
Back Titrations not available
Real Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time
GLP Conformity instrumentation data storage and printing capabilities
Autosampler Compatible not available
Logging Memory up to 100 titration and pH/mV/ISE reports
Connectivity USB: flash drive compatibility for transfer of methods and reports
RS232 for analytical balance
Parallel printer port
Display 5.7 in. (320 x 240 pixel) backlit color LCD
Power Supply 100-240 VAC; -01 models, US plug (type A); -02 models, European plug (type C)
Environment Operating: 10 to 40°C (50 to 104°F), up to 95% RH
Storage: -20 to 70°C (-4 to 158°F), up to 95% RH
Dimensions 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 in.)
Weight approx. 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors

Ordering Info

Each HI931 potentiometric titrator is supplied with titrator, pump assembly, burette assembly, electrodes holder and stirrer, burette blank support, pump and burette locking screws with plastic head, temperature probe, shorting cap, power adapter, USB cable, instruction manual, USB Memory Stick, HI900 PC application (installation kit on USB stick), and quality certificate.

Manuals

Automatic Potentiometric Titrator – HI931

Bestsellers

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range CheckerĀ® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

GroLine Soil pH Tester - HI981030

437.00 AED
The HI981030 GroLine Soil pH Tester is designed to directly measure soil pH for environmental, agricultural testing.
  • ±0.05 pH accuracy
  • Specialized electrode for spot checking the pH of soil and soil slurries
  • Comes with everything necessary to start measuring right away
Back to Top