Out of stock

Pool Line Low Range Phosphate Checker HC – HI7134

HI7134 Phosphate Low Range Checker® Handheld Colorimeter (HC) bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source at a specific wavelength and a light-sensing detector to precisely determine absorbance and ion concentration. The Pool Line Low Range Phosphate Checker HC uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.

  • Precise measurements with no guessing of color
  • Laboratory measurements at a fraction of the cost
  • Simple, intuitive operation

237.00 AED

Inquire Now
SKU:HI7134

HI7134 Pool Line Checker HC is designed for the measurement of low levels of phosphate in swimming pools, hot tubs, and spas. The HI7134 can measure phosphate from 0.00 to 2.50 ppm (as PO43-). Phosphate can be introduced into a swimming pool by either the water that is being added or the breakdown of organic materials such as leaves and grass clippings. Phosphate is commonly added to municipal drinking water to minimize the corrosion of pipes in the distribution system. At high levels phosphate is a nutrient that encourages algae growth. From pool companies, it is recommend to keep phosphate less than 1000 ppb (1.0 ppm) to prevent algae from growing. The water can be treated with chemicals to remove phosphate and the HI7134 Pool Line Checker can be used to monitor and track changes to the phosphate level.

The contoured style of this Checker HC fits in the palm of your and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.

To perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with phosphate to produce a blue color. Last, place the vial into the Checker HC, press the button and read the results. It’s that easy.

How to use Hanna Checker Handheld Colorimeter

Specifications

SKU HI7134
Name Pool Line Low Range Phosphate Checker HC – HI7134
Phosphate Range 0.00 to 2.50 ppm (as PO43-)
Phosphate Resolution 0.01 ppm
Phosphate Accuracy ±0.04 ppm ± 4% of reading
Phosphate Method adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method. The reaction between phosphate and the reagent causes a blue tint in the sample.
Photometer/Colorimeter Light Source LED @ 525 nm
Photometer/Colorimeter Light Detector silicon photocell
Battery Type/Life 1.5V AAA
Automatic Shut-Off after 10 minutes of non-use and 2 minutes after reading
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 64 g (2.3 oz.)
Dimensions 86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)

Ordering Info

HI7134 Checker HC is supplied with sample cuvettes with caps (2 pcs.), phosphate low range reagent starter kit (6 tests), 1.5VAAA battery (1 pc), and instructions that are packaged into a plastic case.

Manuals

Pool Line Low Range Phosphate Checker HC – HI7134

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal
Back to Top
Whatsapp