Out of stock

Pool Line General Purpose Cleaning Solution (500 mL) – HI70614L

HI70614L Pool Line General Purpose Cleaning Solution is a highly effective solution that is formulated for cleaning pH and ORP probes. Electrodes can become coated with a variety of substances when used in swimming pools, hot tubs, and spas. If the probes are not cleaned then inaccurate results can occur. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces. Hanna suggests cleaning the pH and ORP probes on a regular basis to ensure that the sensor is always clean and the junction free flowing.

  • Specially formulated for cleaning pH and ORP electrodes
  • Clearly marked expiration date and lot number for traceability
  • Air-tight seal to ensure the quality of the solution

61.00 AED

Estimated delivery: 24 - 25 June

Inquire Now
SKU:HI70614L

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. The pH meters on the market today will allow an offset voltage (pH 7.01) of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated then any changes to the probe will result in inaccurate readings.

Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI70614L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.

After any cleaning procedure is performed it is important to rehydrate the glass of a pH electrode by placing in storage solution for 15 minutes. After the probe is rehydrated then a calibration must be performed. This is very important for process probes since many are used to monitor and control the dosing of chemicals. It is critical that the probe is clean and calibrated in order for a meter to maintain the ideal set point. The cleaning of pH and ORP process probes should be part of a routine maintenance program.

Screen Shot 2015 01 08 at 3.20.38 PM

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

Each bottle marked with lot number and expiration date.

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Specifications

SKU HI70614L
Name Pool Line General Purpose Cleaning Solution (500 mL) – HI70614L
Description general purpose cleaning solution
Package bottle
Quantity 1
Size 500 mL

Manuals

Pool Line General Purpose Cleaning Solution (500 mL) – HI70614L

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.Ā This probeĀ connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.Ā It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality