Out of stock

Pool Line Combo pH/ ORP Tester – HI981214

HI981214 Pool Line Combo pH/ORP meter is made for measuring pH and ORP of a swimming pool, hot tub, or spa water. This lightweight, waterproof tester offers high accuracy pH, ORP, and temperature measurements in a single handheld unit. No more switching between meters for your routine measurements.

  • Waterproof
  • Replaceable pH Electrode
  • Automatic calibration

878.00 AED

Inquire Now
SKU:HI981214

HI981214 Pool Line Combo tester is a highly accurate, waterproof pH meter that can also measure ORP and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. All pH readings are automatically temperature compensated (ATC) for variations in temperature.HI981214 is ideal for checking the pH and disinfection levels of swimming pools, hot tubs, and spas. The accurate reading of pH is critical to ensure that the chlorine is in predominately the hypochlorous acid form instead of the hypochlorite form, which is less effective at killing bacteria. The ideal pH for a pool is between 7.2 and 7.4.The ORP portion of the meter is used to monitor the disinfection level of the pool to always be sure that there is enough chlorine present to keep bathers safe from bacteria. The ideal ORP reading is +650 mV. At this voltage any bacteria will be inactivated in a short time. It is important to note that if a stabilizer such as cyanuric acid is used that the stabilizer as a reducing agent will mask the oxidation potential of chlorine. ORP should not be used when chlorine is introduced as solid puck since it is likely that it will have stabilizers as well.Replaceable ORP Electrode CartridgeThe HI981214 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!Platinum ORP ElectrodeThe ORP probe uses a platinum tip sensor, which is ideal for oxidation reactions such as adding chlorine for disinfection.

Features at-a-glance:

3 sensors in a single meter

  • pH electrode with extractable junction
  • ORP electrode
  • Temperature probe for pH temperature compensated measurements

Waterproof

  • Designed to float if accidently dropped in sample

Wide Range

  • pH range is from -2.00 to 16.00 pH
  • ORP range of ±1000 mV

Automatic Temperature Compensation

  • All pH readings are compensated for variations in temperature
  • Temperature displayed in oC or oF along with pH or ORP reading

Stability indicator

  • Meter displays a clock tag that will disappear when the reading has achieved stability

HOLD button

  • Freezes reading on the display to allow recording of measurement

BEPS (Battery Error Prevention System

  • Meter will automatically shut off if there is not enough power to get an accurate measurement

Battery % level at startupLow Battery Indicator

  • When the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.

Auto-off

  • Auto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life

Specifications

SKUHI981214
NamePool Line Combo pH/ ORP Tester – HI981214
pH Range-2.00 to 16.00 pH
pH Resolution0.01 pH
pH Accuracy±0.05 pH
pH Calibrationautomatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
pH Temperature Compensationautomatic
ORP Range±1000 mV
ORP Resolution1 mV
ORP Accuracy±2 mV
Temperature Range-5.0 to 60.0 °C (23.0 to 140.0 °F)
Temperature Accuracy±0.5 °C (±1.0 °F)
pH ElectrodeHI73127
Automatic Shut-OffAfter 8 minutes of non-use
Battery Type/Life1.5V (4)/ Approximately 250 hours
Environment-5 to 50 °C (23 to 122 °F); RH 100%
Dimensions171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)
Weight83 g (2.9 oz.)

Ordering Info

HI981214 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 storage solution for pH & ORP electrodes, 20 mL sachet (1 pc.), HI700224 470 mV ORP test solution, 20 ml sachet (2 pcs.), HI7006014pH & ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, storage/protection cap, 1.5V batteries (4 pcs.), instrument quality certificate, and instruction manual.

Manuals

Pool Line Combo pH/ ORP Tester – HI981214

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart