Phosphate High-Range Portable Photometer with CAL Check – HI97717

HI97717 is an advanced portable photometer for the measurement of phosphate in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

Inquire Now
SKU:HI97717-

Phosphates are in many products we use everyday. Most people don’t realize phosphates are used to enhance the flavor and tartness of cola drinks, as a buffering agent to control pH in antifreeze, and to delay the darkening of cut potatoes used for french fries. Phosphates are also used in detergents and cleaning fluids for their ability to soften water and remove soil deposits.

Phosphates are an important fertilizer used in agriculture to enhance the growth and development of plant roots. However, high concentrations of phosphates in agricultural runoff can cause environmental pollution and are a primary cause of eutrophication. Local laws govern the use of phosphates and the discharge levels into streams.

The HI97717 uses an adaptation of the amino acid method to measure phosphate concentrations of up to 30.0 mg/L (ppm). When the reagent is added to samples containing phosphate, the sample will turn a blue hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For high levels of phosphate, a narrow band interference filter at 525 nm allows only blue-green light to be detected by the silicon photodetector and omits all other visible light emitted from the LED lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

photometer optical system
  • LED that generates very little heat.
  • 8 nm narrowband interference filter that is accurate to ±1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output. 
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

On-Screen Features

15p0mgl Certificate Value Screen

CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.

HI97717 Chemical Form Screen

Multiple Chemical Forms
Results can be displayed in multiple chemical forms.

method option

Setup Options
Backlit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.

Measure Tutorial Screen

Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

5c00min Reaction Time Screen

Reaction Timer
Built-in reaction timer that ensures consistency amongst multiple users.

HI97717 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97717 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. 

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Large Cuvette Size:

  • The sample cell of the HI97717 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97717 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Specifications

SKU HI97717-web
Name Phosphate High-Range Portable Photometer with CAL Check – HI97717
Photometer/Colorimeter Light Source LED with 525 nm bandpass filter
Photometer/Colorimeter Light Detector silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round 24.6 mm diameter (22 mm inside)
GLP yes
Display 128 x 64 pixel B/W LCD with backlight
Logging Memory 50 readings
Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67)
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)

Ordering Info

HI97704C is supplied with CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate packaged in a rugged, thermoformed, carrying case.
HI97704 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.

Manuals

Phosphate High-Range Portable Photometer with CAL Check – HI97717

Bestsellers

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range Checker® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality