Out of stock

Phenols Test Kit with Checker Disc – HI3864

The HI3864 is a chemical test kit that uses the aminoantipyrine method to measure phenols in the low (LR) and high range (HR). The HI3864 is supplied complete with all of the reagents and equipment necessary to perform 100 tests.

  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Checker® disc for more accurate determination

584.00 AED

Inquire Now
SKU:HI3864

The HI3864 is a chemical test kit that determines the phenol concentration in two ranges: 0.00 to 1.00 mg/L (LR) and 0.5 to 5.0 mg/L (HR). The HI3864 is supplied with all of the necessary reagents and equipment to perform both analyses, including the Checker® disc. The Checker® disc makes concentration determination more accurate and easier than a typical color comparator.The test kit contains enough reagents to perform 100 tests.

Features at-a-glance

  • Complete setup
    • All required materials are included with the test kit, such as the glass vials, reagent packets, and Checker® disc.
  • High resolution
    • Readings from 0.00 to 1.00 mg/L are determined to 0.02 mg/L resolution.
    • Readings from 0.5 to 5.0 mg/L are determined to 0.1 mg/L resolution.
  • Replacement reagents available
    • There is no need to buy a new kit when reagents are exhausted. The HI3864-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 100 packets of HI3864A-0 and 100 packets of HI3864B-0.

Significance of Use

Phenols are widely used in pharmaceuticals, dyes and indicators, and as general disinfectants. They may occur in household and industrial wastewaters and in natural waters; they can also enter potable water supplies and chlorination of such waters results in malodorous chlorophenol products that are detectable from 0.001 mg/L (1ppb). The Hanna colorimetric method determines phenol and all ortho and para substituted phenols. Since substitution generally lowers the response, the readable value obtained by this method is the minimum concentration of phenolic compounds present. Natural water usually contains less than 0.001 mg/L of phenols, but sometimes values up to 0.02 mg/L (20 ppb) also occur. Since the concentration of phenols in wastewater is generally subjected to biological and chemical degradation, preserve samples in the refrigerator and analyze within four hours after collection.

Specifications

SKU HI3864
Name Phenols Test Kit with Checker Disc – HI3864
Phenols Measurement Type Checker Disc
Phenols Range Low Range:0.00 to 1.00 mg/L
High Range: 0.5 to 5.0 mg/L
Phenols Resolution 0.02 mg/L (0.00 to 1.00 mg/L range); 0.1 mg/L (0.5 to 5.0 mg/L range)
Phenols Method aminoantipyrine
Phenols Number of Tests 100
Weight 573 g (20.2 oz.)
Dimensions 235x175x115 mm (9.2×6.9×4.5 in.)

Ordering Info

HI3864 test kit comes with HI3864A-0 reagent (100 packets), HI3864B-0 reagent (100 packets), checker disc with LR and HR discs, glass vials with caps (2), and a mirror.

Manuals

Phenols Test Kit with Checker Disc – HI3864

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal
Back to Top
Whatsapp
Product has been added to your cart