The mV600 controllers have been engineered with a number of outstanding features to meet all of your process control needs. mV600 offer a multitude of possibilities from ON/OFF or proportional dosage to analog recorder output and alarm. A host of self-testing features and user-friendly functions make mV600 a great value.

  • Accurate, reliable and simple to install.
  • Fully programmable microprocessor memory.
  • Wiring the controllers is simple with extractable terminal modules

2,366.00 AED

Inquire Now
SKU:MV600121-2

The product is a real time microprocessor-based ORPcontroller. It provides accurate measurements, flexible ON/OFF or proportional control capabilities.

mV600 Series ORP Controller’s FEATURES/BENEFITS:

Display

  • Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.

Fail Safe Alarm System

  • Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Differential Input

  • In a system with poor grounding, it is possible to have a ground current flowing through the reference junction. This can cause a rapid degradation of the electrode. The Hanna differential input reduces the likelihood of ground loops.

Proportional Control

  • Slows the pump down when the measured ORP level approaches the set value, which ensures precise dosage and avoids costly waste of chemicals due to overdosage.

Analog Output

  • To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a hard copy of the results on demand.

PC Connectivity

  • RS232C port allows for connection to a PC. Data transmission from the instrument to the PC is possible with the HI 92500 WindowsĀ® compatible application software offered by Hanna Instruments.

Custom Programs

  • Hi-tech microprocessor puts a host of variables at your disposal to fine tune your process, save on chemicals and meet regulatory requirements.

Good Laboratory Practice (GLP)

  • calibration date andtime and the mV calibration points used

Relays

  • 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)

Calibration

  • Automatic 1 or 2 points at 0, 350 and 1900 mV.

Input

  • ORP electrode with BNC connector.

Specifications

SKU mV600121-2
Name Panel-mounted ORP Digital Controller – mV600-single setpoint, on/off and porptional control, single analog output
mV Range ±2000 mV
mV Resolution 1 mV
mV Accuracy ±2 mV
mV (ORP) Calibration automatic, two point, at 0 and 350 or 1900 mV
Temperature Range -9.9 to 120°C
Temperature Resolution 0.1°C
Temperature Accuracy ±0.5°C
Analog Ouput Signal galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC
Digital Output Signal RS232 bi-directional optoisolated
Power Consumption 15 VA
Over Current Protection 5A, 250V fast fuse
Max. Oscillation Frequency 4 MHz
Panel Cutout 140 x 140 mm
Power Supply 230 ±10% VAC , 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 144 x 144 x 170 mm
Weight 1.6 kg (3.5 lb.)

Ordering Info

Each mV 600 model is supplied complete with mounting brackets and instructions.

Manuals

Panel-mounted ORP Digital Controller – mV600-single setpoint, on/off and porptional control, single analog output

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration