Out of stock

Panel-mounted Conductivity Controller – HI700 Series

The HI700 series of controllers offer state of the art specifications for your process control. They can be configured for ON/ OFF, proportional, PI or PID control. Thanks to our exclusive technology, they can be customized to best fit your application.

  • CAL Check™ alerts users of calibration status.
  • Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily.
  • With self-diagnostic features and extractable terminals, installation and maintenance are fast and simple.

AED

Estimated delivery: 20 - 21 May

SKU:HI700-01

HI 700 series controllers are real time microprocessor-based EC controllers. They provide accurate measurements, flexible ON/OFF or proportional control capabilities, analog input and output, RS485 port, dual setpointand alarm signal.The system is composed of a case inside which the signal conversion circuitry, the microprocessor circuitry and the outputpower drivers are contained.

With self-diagnostic features and extractable terminals, installation and maintenance are fast and simple. Password protection guarantees that the calibration and predetermined parameters cannot be altered unnecessarily. The controllers can operate with four-ring probe or 4-20 mA signal. They accept probes with or without a built-in Pt100 temperature sensor.

HI700 Series Conductivity Controller’s FEATURES/BENEFITS:

Display

  • Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.

Indicator LEDs

  • Four LEDs are provided for signaling the energizing of relay 1 and 2 (yellow LEDs) and alarm relays (a greenand a red LED).

PC Connectivity (HI700222 only)

  • RS485 standard is a digital transmission method that allows long lines connections. Its current-loop system makes this standard suitable for data transmission in noisy environments. Data transmission from the instrument to the PC is possible with the HI 92500 Windows® compatible application software offered by Hanna Instruments.

Friendly Interface

  • A menu-driven display aids the user throughout the operations with running messages and clear prompts. All relevant parameters can be simply adjusted and will remain memorized until overwritten.

Programmable Hold System

  • The hold function allows the user to stop the regulating action of the controller for programmable time periods. It is possible to activate the hold periods in correspondence to programmed operations, such as plant maintenance and cleaning procedures.

Programmable Cleaning Cycles

  • Heavy-duty applications often require almost continuous probe maintenance. Elements such as suspended solids, fat, oils, pigments and microorganisms can quickly deposit and soil the electrode. Programmable cleaning cycles allow for scheduled maintenance to keep the probe functioning optimally.

Automatic Temperature Compensation

  • A 2-wire Pt100 can be connected to ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Good Laboratory Practice (GLP)

  • Last calibration data internally recorded for traceability including calibration date and time, cell constant, calibration solution values.

Relays

  • 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)

Calibration

  • Automatic 1 point calibration. alibration and Setup procedures allowed only through an unlock password.

Mult Range Conductivity Measurment

  • Four different EC working ranges (0 to 199.9μS; 0 to1999μS; 0 to 19.99mS; 0 to 199.9mS)

Specifications

SKU HI700-01-web
Name Panel-mounted Conductivity Controller – HI700 Series
EC Range 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm
EC Resolution 0.1 µS; 1 µS; 0.01 mS; 0.1 mS
EC Accuracy ±0.5% f.s. (EC)
EC Calibration automatic or manual at 1 point
EC/TDS Temperature Compensation automatic or manual, -10 to 100°C with adjustable temperature coefficient from 0.00 to 10.00%/°C
Temperature Range -10.0 to 100.0°C
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5°C (0 to 70°C); ±1°C (outside)
Dosing Control two contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Alarm Relay Set Point contact output SPDT 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Analog Input Signal 4-20 mA
Analog Ouput Signal analog: isolated 0-1 mA, 0-20 mA and 4-20 mA; 0-5 VDC, 1-5 VDC and 0-10 VDC or digital: RS485 bi-directional opto-isolated
Power Consumption 15 VA
Over Current Protection 5A, 250V fast fuse
Panel Cutout 140 x 140 mm
Power Supply 115 VAC ±10%; 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 144 x 144 x 170 mm
Weight 1.6 kg (3.5 lb.)

Ordering Info

Each HI700 model is supplied with mounting brackets and instructions.

Manuals

Panel-mounted Conductivity Controller – HI700 Series

Bestsellers

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

597 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7075 Electrolyte Solution 1.7M KNO₃, 0.7M KCl (30 mL x 4)

153 AED
HI7075 is a fill solution that contains 1.7M potassium nitrate (KNO3), 0.7M potassium chloride (KCl) for use in fluoride ion selective electrodes. The electrolyte level in refillable electrodes should be topped off before performing any measurements. If the level is low, refill with the proper electrolyte solution to ensure optimum performance. This simple maintenance helps guarantee adequate head pressure to promote the flow of reference electrolyte into the sample being measured.
  • Fill solution for fluoride ISE
  • Convenient 30 mL bottles
  • Expiration date and lot number clearly marked on the bottle

Combo pH/Conductivity/TDS Tester (High Range) - HI98130

597 AED
The HI98130 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, high range EC/TDS (0.00 to 20.00 mS/cm EC/ 0.00 to 10.00 ppt TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements. Great for hydroponics, aquariums, pools, & ponds
  • Wide range of 0.00 to 14.00 pH
  • Replaceable pH electrode with extractable junction
  • Selectable EC to TDS conversion factor of either a 0.45 or 1.0 β (BETA)

HI7007C pH 7.01 Calibration Solution (500 mL)

55 AED
HI7007C is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight seal

HI7010/1G pH 10.01 Calibration Solution (1 G ( 3.78 L) )

179 AED
HI7010/1G is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Refillable Combination ORP Electrode with BNC Connector - HI3131B

786 AED
The HI3131B is a glass body, refillable, single junction ORP electrode with a BNC connector. This electrode has a single ceramic junction as part of the reference cell and a platinum ORP sensing pin.This design consideration is ideal for laboratories and general purpose ORP measurements, as well as for use as an indicating electrode in ORP titrations.Refillable ElectrodeSingle Ceramic JunctionPlatinum Pin