Out of stock

ORP/Temperature Tester – HI98120

The HI98120 is a waterproof ORP and temperature handheld meter. The housing of this tester is completely sealed to protect against the intrusion of water and is also designed to float if accidentally dropped into a body of water. The HI73120 replaceable ORP electrode is a cartridge design with the stainless steel round connector. With this type of design there are no pins that can bend or break during replacement. The ORP electrode also hase has an extendable cloth junction. This type of junction allows for the renewal of the junction by simply pulling out 3 mm (1/8”) to clear any clogging which improves measurement response time and stability. The exposed stainless steel temperature probe on this meter facilitates a faster, accurate temperature measurement.

  • Waterproof
  • Replaceable ORP Electrode
  • Extractable Junction

656.00 AED

Inquire Now
SKU:HI98120

Similar to a pH measurement that quantifies the how acidic or alkaline solutions are, ORP (Oxidation Reduction Potential) measurements quantify the overall state of a solution as having the ability to oxidize or reduce a chemical species. Oxidizing and reducing reagents are used to participate in chemical reactions known as a redox reaction.An important part of the ORP probe is to have a sensor that is chemically inert; meaning it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold. Both are commonly used in the construction of ORP probes.The platinum sensor is often preferred because it is mechanically simpler to produce. Platinum can be welded to glass and also has a similiar thermal expansion coefficient. Sensors made of gold cannot be welded to the glass and are often placed in plastic supports applied to the glass or plastic tube by means of tiny elastomeric bungs.Many industries rely upon ORP measurements including swimming pools, food processing, boilers and cooling towers, and plating. The measurement of ORP helps the user monitor the effectiveness of disinfecting compounds including chlorine and ozone. ORP is also used to monitor redox reactions including the use of bisulfite in the reduction of hexavalent chromium to trivalent chromium in plating wastewater.

Features at-a-glance:

Waterproof

  • IP67 rated
  • Protects the internal electronics of the meter from an ingress of water in the event that the meter is dropped into a tank or a body of water.

Stability indicator

  • HI98120 features a stability indicator tag on the LCD that will disappear once the reading stabilizes.

Replaceable electrode

  • An electrode last approximately one to two years. It is possible to replace just the electrode and not have to buy a completely new meter.
  • The HI73120 ORP electrode is a simple cartridge design allows the sensor to be easily replaced whether in the lab or in the field.

HOLD feature

  • Allows the reading to be frozen so that the reading can be documented.

Auto-shut off

  • The meter automatically turns itself off after 8 minutes of use in order to conserve battery life in the event the meter is accidently left on.

Battery % level

  • When the meter is turned on the battery % level is displayed as a percentage.

Specifications

SKUHI98120
NameORP/Temperature Tester – HI98120
ORP Range±1000 mV
ORP Resolution1 mV
ORP Accuracy±2 mV
Temperature Range-5.0 to 60.0°C / 23.0 to 140.0°F
Temperature Resolution0.1°C / 0.1°F
Temperature Accuracy±0.5°C /±1°F
ORP ElectrodeHI73120 replaceable ORP electrode (included)
Automatic Shut-Offafter 8 minutes of non-use
Battery Type/Life1.5V (4) / approx. 300 hours of continuous use
Environment-5 to 50°C (23 to 122°F); RH max 100%
Dimensions163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)
Weight100 g (3.5 oz.)

Ordering Info

HI98120 (ORP) is supplied with HI73120 ORP electrode, HI73128 electrode removal tool, batteries and instructions.

Manuals

ORP/Temperature Tester – HI98120

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart