Nitrate Portable Photometer with CAL Check – HI97728

HI97728 is an advanced portable photometer for the measurement of nitrate as nitrate-nitrogen in water up to 30.0 mg/L. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check for performance verification and calibration

Estimated delivery: 15 - 16 January

Inquire Now
SKU:HI97728-

In domestic water, nitrate is monitored due to the health effects that it has on newborn babies. High level of nitrates can cause a condition known as methemoglobinemia or “blue-baby syndrome”. The EPA has set the maximum contaminant level in water at 10 mg/l. The HI97728 uses cadmium reduction method for measuring nitrate up to 30.0 mg/L (ppm) in water from 0.0 to 30.0 mg/L.

The method uses a reagent with cadmium to reduce the nitrate in the water to nitrite. In an acidic medium the nitrite ion reacts with sulfanilic acid to form a salt that reacts with other reagents to produce a colored solution that is proportional to the concentration of nitrate that was in the sample.

The HI97728 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences.

HI97728 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75″) by 37 mm (1.6″) and is backlit for easy viewing under all conditions

photometer optical system
  • LED that generates very little heat
  • 8 nm narrowband interference filter that is accurate to ±1 nm and offers 25% increase in light efficiency.
  • Reference detector that modulates the voltage to LED for consistent light output.
  • A concave focusing lens that reduces errors from imperfections in the cuvette

HI97728 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97728 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement..

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes..

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Built-in Reaction Timer:

  • Waiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.

Large Cuvette Size:

  • The sample cell of the HI97728 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97728 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Specifications

SKU HI97728-web
Name Nitrate Portable Photometer with CAL Check – HI97728
Nitrate Range 0.0 to 30.0 mg/L (as NO3-N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading at 25 °C
Nitrate Method Adaptation of Cadmium Reduction Method
Photometer/Colorimeter Light Source Light Emitting Diode with 525 nm narrow band interference filter
Photometer/Colorimeter Light Detector silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round 24.6 mm diameter (22 mm inside)
GLP yes
Display 128 x 64 pixel B/W LCD with backlight
Logging Type auto-logging
Logging Memory last 50 readings
Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH (IP67)
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)

Ordering Info

HI97728C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate packaged in a rugged thermoformed carrying case.

HI97728 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3),instruction manual, and instrument quality certificate.

Manuals

Nitrate Portable Photometer with CAL Check – HI97728

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

Refillable Combination pH Electrode with BNC Connector - HI1131B

576.00 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

703.00 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
Back to Top
Whatsapp
Product has been added to your cart