Multiparameter Benchtop Photometer and pH meter – HI83300

HI83300 is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.To save valuable laboratory benchtop space, the HI83300 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.

Advanced optical system

Unparalleled performance from a benchtop photometer

Digital pH electrode input

Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter

Absorbance measuring mode

Allows performance verification using CAL Check standards

view compatible reagents

4,026 AED

Estimated delivery: 20 - 21 September

Inquire Now
SKU:HI83300-01

From aluminum to zinc, the HI83300 benchtop photometer measures 37 different key water quality parameters using 60 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.A digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.The HI83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery. 

Features/Benefits:

Backlit 128 x 64 Pixel Graphic LCD Display

  • Backlit graphic display allows for easy viewing in low light conditions
  • The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter

Built-in Reaction Timer for Photometric Measurements

  • The measurement is taken after the countdown timer expires.
  • Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements

Absorbance mode

  • Hanna’s exclusive CAL Check cuvettes for validation of light source and detector
  • Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry

Units of Measure

  • Appropriate unit of measure along with chemical form is displayed along with reading

Result Conversion

  • Automatically convert readings to other chemical forms with the touch of a button

Cuvette Cover

  • Aids in preventing stray light from affecting measurements
Digital pH Electrode Input

  • Measure pH and temperature with a single probe
  • Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
  • pH CAL Check alerts user to potential problems during the calibration process
  • Space saving having a pH meter and photometer built into one meter

Data Logging

  • Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button
  • Sample ID and User ID information can be added to a logged reading using alphanumeric keypad

Connectivity

  • Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
  • Data is exported as a .CSV file for use with common spreadsheet programs

Battery Status Indicator

  • Indicates the amount of battery life left

Error Messages

  • Photometric error messages include no cap, high zero, and standard too low
  • pH calibration messages include clean electrode, check buffer and check probe

On-screen Features

method selectionMethod SelectionUsers can easily select any one of the 60 measurement methods via the dedicated METHOD button.
data loggingData LoggingUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.
ph measurement modepH Measurement ModeSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.

 

Advanced Optical System

HI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer. 

photometer multiparameter optical

 

High Efficiency LED Light Source

An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

High Quality Narrow Band Interference Filters

The narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

Reference Detector for a Stable Light Source

A beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

Large Cuvette Size

The sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

Specifications

SKU HI83300-01
Name Multiparameter Benchtop Photometer and pH meter – HI83300
pH Range Photometer: 6.5 to 8.5 pH
pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH
pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH
pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV
Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2)
Dissolved Oxygen Resolution 0.1 mg/L
Dissolved Oxygen Accuracy ±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range 0.000 to 4.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy ±0.003Abs @ 1.000 Abs
Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3)
Seawater: 0 to 500 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric method
Aluminum Range 0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution 0.01 mg/L
Aluminum Accuracy ±0.04 mg/L ±4% of reading
Aluminum Method Adaptation of the aluminon method
Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N)
Medium Range: 0.00 to 10.00 mg/L (as NH3-N)
High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading
Medium Range: ±0.05 mg/L ±5% of reading
High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution 0.01 mg/L
Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading
Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS.
Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+)
Seawater: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading
Seawater: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method
Seawater: Adaptation of the Zincon method
Chloride Range 0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Ultra Low Range: 0.001 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Ultra Low Range: ±0.020 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Ultra High Range: 0 to 500 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Ultra Low Range: 0.001 mg/L
Ultra High Range:1 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Ultra Low Range: ±0.020 mg/L ±3% of reading
Ultra High Range: ±3 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method
Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl
Chromium, Hexavalent Range Low Range: 0 to 300 µg/L (as Cr6+)
High Range: 0 to 1000 µg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 µg/L
Chromium, Hexavalent Accuracy Low Range: ±1 µg/L ±4% of reading
High Range: ±5 µg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.
Color, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution 1 PCU
Color, Water Accuracy ±10 PCU ±5% of reading
Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.
Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+)
High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading
High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
Fluoride Range Low Range: 0.00 to 2.00 mg/L (as F)
High range: 0.0 to 20.0 mg/L (as F)
Fluoride Resolution 0.01 mg/L; 0.1 mg/L
Fluoride Accuracy Low Range: ±0.03 mg/L ±3% of reading
High Range: ±0.5 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total Range Low Range: 0 to 250 mg/L (as CaCO3)
Medium Range: 200 to 500 mg/L (as CaCO3)
High Range: 400 to 750 mg/L (as CaCO3)
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range: ±5 mg/L ±4% of reading
Medium Range: ±7 mg/L ±3% of reading
High Range: ±10 mg/L ±2% of reading
Hardness, Total Method Adaptation of the EPA recommended method 130.1
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range 0 to 400 µg/L (as N2H4)
Hydrazine Resolution 1 µg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method
Iodine Range 0.0 to 12.5 mg/L (as I2)
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron Range Low Range: 0.000 to 1.600 mg/L (as Fe)
High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution 0.001 mg/L; 0.01 mg/L
Iron Accuracy Low Range: ±0.01 mg/L ±8% of reading
High Range: ±0.04 mg/L ±2% of reading
Iron Method Low Range: Adaptation of the TPTZ Method
Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method
Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method
Manganese Range Low Range: 0 to 300 µg/L (as Mn)
High Range: 0.0 to 20.0 (as Mn)
Manganese Resolution 1 µg/L; 0.1 mg/L
Manganese Accuracy Low Range: ±10 µg/L ±3% of reading
High Range: ±0.2 mg/L ±3% of reading
Manganese Method Low Range: Adaptation of the PAN Method
High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
Nickel Range Low Range: 0.000 to 1.000 mg/L (as Ni)
High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution 0.001 mg/L; 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading
High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method
High Range: Adaptation of the photometric method
Nitrate Range 0.0 to 30.0 mg/L (as NO3– N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
Nitrite Range Freshwater
Low Range: 0 to 600 µg/L (as NO2-N)
High Range: 0 to 150 mg/L (as NO2)
Seawater Ultra Low Range: 0 to 200 µg/L (as NO2-N)
Nitrite Resolution Freshwater: 1 µg/L; 1 mg/L
Seawater: 1 µg/L
Nitrite Accuracy Freshwater
Low Range: ±20 µg/L ±4% of reading
High Range: ±4 mg/L ±4% of reading
Seawater
±10 µg/L ±4% of reading
Nitrite Method Adaptation of the EPA Diazotization method 354.1
Oxygen, Scavenger Range 0 to 1000 µg/L (as DEHA)
0.00 to 1.50 mg/L (as Carbohydrazide)
0.00 to 2.50 mg/L (as Hydroquinone)
0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution 1 µg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy ±5 µg/L ±5% of reading (DEHA)
Oxygen, Scavenger Method Adaptation of the iron reduction method
Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method
Phosphate Range Freshwater
Low Range: 0.00 to 2.50 mg/L (as PO43-)
High range: 0.0 to 30.0 mg/L (as PO43-)
Seawater Ultra Low Range: 0 to 200 µg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L
Seawater: 1 µg/L
Phosphate Accuracy Freshwater
Low Range: ±0.04 mg/L ±4% of reading
High Range: ±1 mg/L ±4% of reading
Seawater Ultra Low Range: ±5 µg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method
Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
Potassium Range 0.0 to 20.0 mg/L (as K)
Potassium Resolution 0.1 mg/L
Potassium Accuracy ±3.0 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method
Silica Range Low Range: 0.00 to 2.00 mg/L (as SiO2)
High Range: 0 to 200 mg/L (as SiO2)
Silica Resolution 0.01 mg/L; 1 mg/L
Silica Accuracy Low Range: ±0.03 mg/L ±3% of reading
High Range: ±1 mg/L ±5% of reading
Silica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method
Sulfate Range 0 to 150 mg/L (as SO42-)
Sulfate Resolution 1 mg/L
Sulfate Accuracy ±5 mg/L ±3% of reading
Sulfate Method Turbidimetric – Sulfate is precipitated with barium chloride crystals
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode digital pH electrode (not included)
Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detector silicon photodetector
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1 nm
Cuvette Type round, 24.6 mm
Number of Methods 128 max.
GLP calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Logging Type log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Environment 0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing
Weight 1.0 kg (2.2 lbs.)
Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8”)

Ordering Info

HI83300 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Manuals

Multiparameter Benchtop Photometer and pH meter

Bestsellers

Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

481 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

Digital Glass Body pH Electrode for General Purpose - HI11310

601 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass
Inquire Now

® Multiparameter EC/TDS/Salinity Meter - HI2030

2,530 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

Refillable Double Junction pH Electrode with BNC Connector - HI1043B

743 AED
The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature Glass
Inquire Now

HALO® Bluetooth® Wireless pH Meter for Flat Surfaces - HI14142

932 AED
The HI14142 HALO is an innovative pH electrode with Bluetooth® Smart technology designed for flat surfaces Our HALO® Wireless pH Meter for Flat Surfaces has a flat tipped glass sensor and an open junction design to measure pH on flat surfaces or small volume samples. All readings are transmitted directly to your Apple or Android device or the edge®blu. One Press Connect Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology. Status Indicator Visible from a distance, the LED “halo” light flashes to indicate the status of the probe. Easy-to-Replace battery The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.
Inquire Now

Foodcare pH Electrode for Meat Products with Quick Connect DIN Connector - FC2323

932 AED
The FC2323 is an amplified single junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The FC2323 electrode features a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration, along with the optional stainless steel blades, is ideal for pH measurements in meat and semi-frozen food products. The recommended operating temperature range is from 0 to 50℃.
  • Low Temperature Glass
  • Stainless Steel Piercing Blade (Optional)
  • Open Junction