Multi-Range Portable EC/TDS Meter – HI8033

The HI8033 is a durable, portable EC/TDS meter designed for a wide variety of applications. It is supplied with a four-ring conductivity probe to allow for three ranges of EC measurement and one range of TDS measurement. The temperature compensation coefficient (β) is fixed at 2%/℃ and all conductivity readings are manually adjusted for temperature, assuring consistent and accurate measurements.

  • Four-ring probe
  • Three measuring ranges
  • 0.1 µS/cm resolution

1,139.00 AED

Estimated delivery: 25 - 26 April

Inquire Now
SKU:HI8033

Features

HI76301W four-ring conductivity probe eliminates the polarization effectThree Measurement Ranges selected by a dial on the face of the meterThe meter is programmed to let the user know when a new range should then be selectedManual temperature compensation allows users to adjust the temperature of the measurement solution with a range of 0 to 50℃ (32 to 122℉)Manual one-point calibration in a standard conductivity solution

Specifications

SKUHI8033
NameMulti-Range Portable EC/TDS Meter – HI8033
EC Range0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm
EC Resolution0.1 µS/cm; 1 µS/cm; 0.01 mS/cm
EC Accuracy±1% FS (excluding probe error)
EC Calibrationmanual, one-point
TDS Range0 to 19990 mg/L (ppm)
TDS Resolution10 mg/L (ppm)
TDS Accuracy±1% FS (excluding probe error)
TDS Calibrationmanual, one-point
EC/TDS Temperature Compensationmanual
EC/TDS ProbeHI76301W conductivity probe with 1 m (3.3’) cable (included)
Battery Type/Life9V / approximately 100 hours of continuous use
Environment0 to 50°C (32 to 122°F); RH max 100%
Dimensions185 x 82 x 47 mm (7.3 x 3.2 x 1.9”)
Weight270 g (9.5 oz.)

Ordering Info

HI8033 is supplied with HI76301W conductivity probe, battery, and instructions.

Manuals

Multi-Range Portable EC/TDS Meter – HI8033

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal