Mulitparameter (pH/ORP/EC/DO/Temp) Probe with 4m Cable

The HI769828 is a multiparameter pH/ORP/EC/DO/Temperature probe for use with the HI9828 portable meter. Sensors are automatically recognized by the probe and meter when connected. Sensor replacement is quick and easy with field replaceable, screw type connectors that are color-coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, and 20m lengths available. It’s rugged, waterproof design makes it ideal for field use.

Color Coded, Field Replaceable Sensors

Built-in Microprocessor

IP68 Rating

Inquire Now
SKU:HI769828/4

The multisensor probe can support 3 different sensors: DO, EC, pH or pH/ORP.

Features at-a-glance

Waterproof Protection – The HI769828 probe features an IP68 rating for continuous immersion in water.

Color Coded, Field Replaceable Sensors – Sensor replacement is quick and easy with field replaceable, screw type connectors that are color coded for easy sensor port identification.

Auto-sensor Recognition – The probe and meter automatically recognize the pH and pH/ORP probe sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.

Automatic Temperature Compensation (ATC) – Integrated temperature sensor allows for automatic temperature compensation of pH, ion selective, conductivity, and dissolved oxygen measurements.

Available Sensors

The HI769828-0 is a PEI plastic body, double reference, gel filled pH electrode. This pH/ORP electrode for the Hanna family of multiparameter portable meters including the HI98280. The electrode has a rugged PEI (polyetherimide) body that offers excellent chemical resistance in an unbreakable plastic making it ideal for field and industrial applications.The HI769828-0 has a glass pH sensing tip with a double reference electrode in gel electrolyte and a cloth junction.

The HI769828-1 combination pH/ORP sensor features a glass sensitive bulb for pH readings, a platinum sensor for redox measurements and a double junction reference with gel electrolyte and cloth junction for use with the HI769828 probe.The electrode has a rugged PEI (polyetherimide) body that offers excellent chemical resistance in an unbreakable plastic making it ideal for field and industrial applications.

The HI769828-2 is a galvanic dissolved oxygen membrane sensor for use with the HI769828 probe. The sensor body is constructed of durable PVC material and contains an easily replaceable membrane cap design. The membranes are constructed of PTFE and each cap screws easily onto the sensor. The HI769828-2 sensor contains a silver cathode and zinc anode.

The HI769828-3 is a 4-ring electrode conductivity (EC/TDS/Resistivity/ Salinity) sensor for use with the HI769828 Probe. The sensor body is constructed of durable PVC material and contains AISI 316 stainless steel electrodes that are not subject to polarization or surface coating effects.

**This is the housing only. Sensors sold separately.

Specifications

SKU HI769828/4
Name Mulitparameter (pH/ORP/EC/DO/Temp) Probe with 4m Cable
Maximum Depth 20 m (66 ft.)
Probe Dimensions L=270 (10.6”)
IP Protection IP68
Probe Weight 750g (2604 oz.)
Temperature Sensor Type 316 SS
Body Material ABS
Temperature Operating Range -5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K
Cable Multistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb) intermittent use
Notes Applications: Environmental, Wastewater Treatment, Water Analysis, Industrial, Aquaculture

Manuals

Mulitparameter (pH/ORP/EC/DO/Temp) Probe with 4m Cable

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top