Marine Master Waterproof Wireless Multiparameter Photometer – Meter Only | HI97115

marine

pH, Alkalinity, Ammonia, Calcium, Magnesium,Nitrate Low Range, Nitrate High Range, NitriteUltra Low Range, Phosphate Ultra Low Range

The HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.

Estimated delivery: 19 - 20 September

Inquire Now
SKU:HI97115

Marine, Saltwater Aquariums, Aquaculture

Precise and advanced LED optical system

The HI97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.

  • Precise and advanced LED optical system
  • Waterproof and floating IP67 meter design
  • Meter validation using certified CAL Checkā„¢ cuvettes
  • Includes auto data logging features to easily record up to 200 water testing results
  • On-screen tutorial mode guides users step-by-step through the measurement process
  • Option to assign locations to logged readings
  • Positive-locking system ensures that the cuvettes are placed into the holder in the same position every time
  • Future compatibility with Hanna Cloud

Innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

diag
HI97106 HANNA SPECS

CAL Checkā„¢ Validation

Hanna’s exclusive CAL Checkā„¢ feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Checkā„¢ standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.Tutorial mode can be enabled or disabled from the setup menu.

On-Screen Tutorials

The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents, and quantities.

Tank Selection and Multiple Reading Locations Management

Users can edit up to 25 different tanks, correlate reading location to any location from the list so that logged data is linked to its reading location.

Data Logging

Missed a measurement? No need to worry because your photometer will automatically log the last 200 measurements. The results can be viewed instantly using the Log Recall Menu.


HI97106 HANNA SPECS

Advanced Optical System

A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.

Large Cuvette Size

The 25-mm path length cuvette allows light to pass though more of the sample ensuring accurate measurements even in low-absorbance samples.

Positive Locking System

Cuvettes are placed into the holder in the same position every time by ensuring that the notch on the cap is positioned securely in the cell’s groove.

Portable Design

Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.


Ordering Information:

We believe that buying a meter should be simple. Your HI97115 photometer has many of the necessary accessories needed for successful measurements.

Each HI97115 is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cap (2 pcs.)
  • Alkaline batteries: 1.5V AA (3 pcs.)
  • Instrument quality certificate
  • A quick reference guide with instructions for manual download

HI97115C** is delivered in a rugged carrying case and is supplied with sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); marine pH reagent, 30 mL dropper (1 pc.), Marine Alkalinity reagent, 30 mL bottle (1 pc.); Marine Ammonia starter kit – reagent A, 30 mL dropper (1 pc.), reagent B and C (reagent for 25 tests, each); Marine Calcium starter kit – reagent A, 30 mL bottle (1 pc.), reagent B (reagent for 25 tests); Marine Magnesium starter kit – reagent A, 120 mL bottle (1 pc.); Magnesium indicator reagent (for 25 tests); Marine Nitrate High Range reagent (reagent for 25 tests); Marine Nitrite Ultra Low Range reagent (reagent for 25 tests); Marine Phosphate Ultra Low Range reagent (reagent for 25 tests); 1 mL graduated syringe with tip (3 pcs.); minipipette with tip (1 pc.); 3 mL Pasteur pipette (2 pcs.); 5 mL syringe with black printing and tip (1 pc.); 5 mL syringe with blue printing and tip (1 pc.); 1.5V AA alkaline batteries (3 pcs.); cloth for wiping cuvettes; scissors; instrument quality certificate; and quick reference guide with instructions for manual download. * CAL Check standards sold separately. Nitrate LR testing reagent not included. ** HI97115UC is instrument code for USA.

Specifications

SKU HI97115
Name Marine Master Waterproof Wireless Multiparameter Photometer – Meter Only | HI97115
Marine pH Range 6.3 to 8.6 pH
Marine pH Resolution 0.1 pH
Marine pH Accuracy ±0.2 pH of reading at 25 °C
Marine pH Method Colorimetric Adaptation of the Phenol Red Method
Marine pH LED 525 nm
Marine Alkalinity Range 0.0 to 20.0 dKH
Marine Alkalinity Resolution 0.1 dKH
Marine Alkalinity Accuracy ±0.3 dKH ±5 % of reading at 25 °C
Marine Alkalinity Method Colorimetric Method
The reaction causes a distinctive range of colors from yellow to greenish blue to develop.
Marine Alkalinity LED 610 nm
Marine Ammonia Range 0.00 to 2.50 ppm (as NHā‚ƒ)
Marine Ammonia Resolution 0.01 ppm
Marine Ammonia Accuracy ±0.05 ppm ±5% of reading at 25 °C
Marine Ammonia Method Adaptation of the Salicylate Method The reaction between Ammonia and Ammonium and the reagent causes a blue-green tint in the sample.
Marine Ammonia LED 610 nm
Marine Calcium Range 200 to 600 ppm
Marine Calcium Resolution 1 ppm
Marine Calcium Accuracy ±6% of reading at 25 °C
Marine Calcium Method Adaptation of the Zincon Method
Marine Calcium LED 610 nm
Marine Magnesium Range 1000 to 1800 ppm (as Mg2+)
Marine Magnesium Resolution 5 ppm
Marine Magnesium Accuracy ±5% of reading at 25 °C
Marine Magnesium Method Adaptation of the Colorimetric EDTA Method using calmagite indicator
The reaction between magnesium and the reagents causes a blue to violet tint in the sample.
Marine Magnesium LED 610 nm
Marine Nitrate LR Range 0.00 to 5.00 ppm (as NOā‚ƒā€“)
Marine Nitrate LR Resolution 0.01 ppm
Marine Nitrate LR Accuracy ±0.25 ppm ±2% of reading at 25 °C
Marine Nitrate LR Method Zinc Reduction Method
The reaction between nitrate and the reagent causes a pink tint in the sample.
Marine Nitrate LR LED 525 nm
Marine Nitrate HR Range 0.0 to 75.0 ppm (as NOā‚ƒā€“)
Marine Nitrate HR Resolution 0.1 ppm
Marine Nitrate HR Accuracy ±2.0 ppm ±5% of reading at 25 °C
Marine Nitrate HR Method Zinc Reduction Method
The reaction between nitrate and the reagent causes a pink tint in the sample.
Marine Nitrate HR LED 525 nm
Marine Nitrite ULR Range 0 to 200 ppb (as NO₂–-N)
Marine Nitrite ULR Resolution 1 ppb
Marine Nitrite ULR Accuracy ±10 ppb ±4% of reading at 25 °C
Marine Nitrite ULR Method Adaptation of the EPA Diazotization Method 354.1
The reaction between nitrite and the reagent causes a pink tint in the sample.
Marine Nitrite ULR LED 525 nm
Marine Phosphate ULR Range 0.00 to 0.90 ppm
Marine Phosphate ULR Resolution 0.01 ppm
Marine Phosphate ULR Accuracy ±0.02 ppm ±5% of reading at 25 °C
Marine Phosphate ULR Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method
Marine Phosphate ULR LED 610 nm
Measurement System Light source LED
Measurement System Bandpass filter wavelength 525 nm & 610 nm
bandwidth 8 nm wavelength accuracy ±1.0 nm
Measurement System Light detector silicon photocell
Measurement System Cuvette Type round 24.6 mm diameter (22 mm inside diameter)
Additional Specifications Auto logging 200 readings
Additional Specifications Display 128 x 64 pixel B/W LCD with backlight
Additional Specifications Auto-off after 15 minutes of inactivity (30 minutes before a READ measurement)
Additional Specifications Battery type / Life alkaline 1.5 V AA (3) / > 800 measurements (without backlight)
Additional Specifications Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
Additional Specifications Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)
Additional Specifications Weight 380 g (13.4 oz.); with batteries
Additional Specifications Casing IP67 rating, floating

Manuals

Marine Master Waterproof Wireless Multiparameter Photometer – Meter Only | HI97115

Bestsellers

Inquire Now

Portable pH/EC/TDS/Temperature Meter - HI9811-51

753.00 AED
The HI9811-51 is an economical, wateproof, portable meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature (ā„ƒ) with a single probe. The meter operation is simplified with dedicated buttons for measurement modes to be be displayed on the LCD and knobs for single point calibration of pH and EC/TDS. The HI9811-51 is most suitable for agricultural, greenhouse and hydroponic applications.
  • 3 in 1 probe with pH, EC/TDS and temperature sensors
  • Amplified pH electrode for immunity to electrical noise including from ballasts and pumps
  • Large LCD with instructions
Inquire Now

Iron (Low Range) Test Kit Replacement Reagents (100 tests) - HI38039-100

82.00 AED
The HI38039-100 are replacement reagents for the colorimetric determination of iron with the HI38039 Iron Low Range Test Kit. There are enough reagents for approximately 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

Marine Master Waterproof Wireless Multiparameter Photometer - Kit | HI97115C

pH, Alkalinity, Ammonia, Calcium, Magnesium,Nitrate Low Range, Nitrate High Range, NitriteUltra Low Range, Phosphate Ultra Low RangeThe HI97115 is a compact and versatile Marine multiparameter photometer designed to accurately determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI97115 is suitable for field and bench measurements.
Inquire Now

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Basic probe - with turbidity-20m (65.6')

13,657.00 AED
The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.
Inquire Now

HI83306-11 CAL CheckTM Cuvette Kit for HI83306 Environmental Analysis Photometer

633.00 AED
The HI83306-11 CAL CheckTM Standards provides a simple method for calibrating and validating the HI83306 Environmental Analysis Photometer. This high-quality set of standards comes with a certificate of analysis.
  • Absorbance values at 420 nm, 466 nm, 525 nm, 610 nm, and 0 nm
  • Supplied with Certificate of Analysis
  • Reusable with a long shelf-life

Desiccant Cartridge for Titrant or Vessel for HI903 - HI900532

228.00 AED
The HI900532 is a glass desiccant cartridge with cover designed to fit the titrant bottle or titration vessel enclosures for the HI903 Karl Fischer Titration System.Each cartridge comes sealed and filled with dry silica gel desiccant ready for immediate use upon opening. The rechargeable, color-indicating silica gel prevents the ingress of ambient humidity in the sealed system. It’s color change allows the user to recognize when it’s adsorption capacity has been depleted.
  • Color indicating desiccant
  • Quick replacement
  • Easy to assemble

Desiccant Cartridge for Solvent or Waste for HI903 - HI900533

228.00 AED
The HI900533 is a glass desiccant cartridge with cover designed to fit the solvent or waste bottle enclosures for the HI903 Karl Fischer Titration System.Each cartridge comes sealed and filled with dry silica gel desiccant ready for immediate use upon opening. The rechargeable, color-indicating silica gel prevents the ingress of ambient humidity in the sealed system. It’s color change allows the user to recognize when it’s adsorption capacity has depleted.
  • Color indicating desiccant
  • Quick replacement
  • Easy to assemble
Back to Top
Whatsapp
Product has been added to your cart