Out of stock

Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution – HI5221

The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5221 is rich in features including five-point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and much more. This meter retains simplicity with both dedicated keys for routine operation and virtual keys that guide the user through setup options.

The HI5221 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.

  • Capacitive Touch Keypad
  • Large Color LCD
  • CAL Check™

3,003 AED

Estimated delivery: 20 - 21 May

SKU:HI5221-01

The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.

The HI5221 features a universal BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100℃. All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe that is included.

The HI5221 can be calibrated up to five points with a choice of eight preprogrammed buffers or five custom buffers. The HI5221 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process such as “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. The calibration data including date, time, buffers used, offset and slope can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.

Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100, 000 data points can be recorded in 100 lots with 50, 000 records max/lot and exported to a computer for data review and storage.

Features at-a-glance

Highly Customizable User Interface – The user interface of the HI5221 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits.

Color Graphic LCD – The HI5221 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for real-time graphing and the use of virtual keys provide for an intuitive user interface.

Capacitive Touch – The HI5221 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue.

Choice of Calibration – Automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.

GLP Data – HI5221 includes a GLP Feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, buffers /standards used for calibration and slope characteristics. The offset is also displayed for pH electrodes.

CAL Check™ – CAL Check™alerts users to potential problems during the calibration of the pH electrode. Indicators include “Electrode Dirty/Broken, ” “Buffer Contaminated, ” electrode response time and the overall probe condition as a percentage that is based on the offset and slope characteristics.

Data Logging – Three selectable logging modes are available on the HI5221: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50, 000 records max/lot, with up to 100, 000 total data points. Automatic logging features the option to save data according to sampling period and interval.

Data Transfer – Data can be transferred to a PC with USB cable and HI92000 software (both sold separately).

Contextual Help – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

CAL check

CAL Check Feature

GLP

Comprehensive GLP Data

Logging

Real-Time Logging

Specifications

SKU HI5221-01
Name Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution – HI5221
pH Range -2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD
pH Calibration automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
pH CAL Check (electrode diagnostics) Yes
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ±1 LSD
mV Relative Offset ±2000 mV
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K
Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy ±0.2 °C, ±0.4 °F, ±0.2 K
Input Channels 1 – pH/ORP
pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging Type automatic, manual, AutoHold
Logging Memory record: 100,000 data point storage, 100 lots with 50,000 records/lot
Logging Interval settable between 1 second and 180 minutes max log time
Connectivity USB
GLP calibration data including date, time, buffers used, offset and slope
Display color graphic LCD with on-screen help, graphing, and custom color configuration
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
Weight 1.2 kg (2.64 lbs.)

Ordering Info

HI5221 is supplied with HI1131B pH electrode, HI7662-T temperature probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC adapter and instructions.

Manuals

Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution – HI5221

Bestsellers

Refillable Combination pH Electrode with BNC Connector - HI1131B

543 AED
The HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.
  • Refillable Electrode
  • Double Junction Design
  • High Temperature (HT) Glass

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

597 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

663 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

Marine Nitrite Ultra Low Range Checker® HC Calibration Check Set - HI764-11

55 AED
The Marine Nitrite Ultra Low Range Checker® HC Calibration Check Set - HI764-11 provides a simple solution to validating the Nitrite Ultra Low Range Checker® HC - HI764 that has a range of 0 to 200 ppb. This high-quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a Certificate of Analysis. The Certificate of Analysis provides the lot number, reference values and expiration date for traceability when certifying the Checker® HC.
  • Supplied with Certificate of Analysis
  • Standard value of 100 ±14 ppb nitrite @ 25℃
  • Reusable with long shelf life stability

Iron High Range Reagents (100 tests) - HI93721-01

88 AED
The HI93721-01 are reagents for the colorimetric determination of iron. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

HI7007C pH 7.01 Calibration Solution (500 mL)

55 AED
HI7007C is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight seal

Pure Water Tester (0.0 - 99.9 µS/cm) - HI98308

263 AED
The HI98308 Pure Water tester is a rugged and reliable pocket-sized tester that offers quick and accurate readings. The HI98308 Pure Water tester features graphite electrodes to reduce polarization effects and an exposed temperature probe for fast response when compensating for temperature changes. Manual calibration is performed to a single point.
  • Exposed temperature sensor
  • Very low range EC 0.0 to 99.9 µS/cm
  • Single point manual calibration
Back to Top