Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-HF – Hydrofluoric Acid Resistant-None

Hanna presents a series of combination pH and ORP electrodes, including more than 300 models, incorporating over 20 years of electrode manufacturing experience.
The most advanced feature of this series is the electrode shape with a flat tip, virtually eliminating deposits that can foul the electrode, significantly reducing necessary maintenance. This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.

  • PVDF body
  • Self-cleaning flat tip sensor for significantly reduced maintenance.
  • Provided with an internal matching pin that can avoid typical problems caused by grounding loop current.
  • 3/4″ NPT external thread on both ends for easy installation

1,456.00 AED

Inquire Now
SKU:HI1006-4005

A Worldwide Leader in Electrode Manufacturing

Since the beginning of the 1990’s Hanna has been a leader in the research & development of pH and ORP electrodes. Today, Hanna is proud to
present the latest family of industrial electrodes, the Flat Tip Series, which completes the wide range of Hanna probes for any process application.
All Hanna industrial pH and ORP electrodes are combination type, i.e. the reference half cell and the measurement half cell are assembled in the
same body.

Flat tip pH Electrode

Advantage of flat tip electrodes

  • In a continuous in-line installation, the glass sensor of the pH electrode can be physically damaged by solution streams containing suspended solids.

  • Our Flat Tip electrodes are the best answer to this problem. The flat tip virtually eliminates deposits that can foul the electrode, significantly reducing necessary maintenance.

  • This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.
matching pin

Each pH electrode is provided with an internal matching pin that can avoid typical problems caused by grounding loop current, such as:

  • progressive damage of the electrode
  • fluctuating measurements
  • poor process regulation

In many industrial applications, especially in plating baths, grounding loop current is a very common problem.
When a traditional electrode/controller system is used with the electrode reference connected both to the electrode and to the instrument, a current flow occurs through the reference half cell, causing fluctuations in reading and serious damage to the Ag/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above, the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly, the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.

Flat tip pH dimensions

Installation

These electrodes have been designed with ¾ā€ external thread on both ends for easy installation. HANNA instrumentsĀ® also provides a series of probe holders for in-line, tank or by-pass installations for these electrodes, as shown below.

Front thread ¾ā€ NPT

  • Direct in-line installation ¾ā€ standard teeĀ 
  • Immersion installation in vessel, tank, plating bath with HI 60501 (PVC) or HI 60503 (PVDF) electrode holders with adjustable immersion level: min 10 cm, max 70 cmĀ 
  • Direct pipe installation with HI 60542 PVC electrode holder, 2″ thread

Back thread ¾ā€ NPT

  • Immersion installation with ¾” threaded pipeĀ 
  • By-pass installation with HI 60545 By-pass electrode holder ā€œLoopā€ configuration Liquid inlet: ¾” Liquid outlet: ¾

HI1006 Series Flat Tip pH Electrode FEATURES/BENEFITS:

Junction

Three junction types are available:

  • Ā Annular non-clogging PTFE junction, for testing solutions with high content of suspended solids or for high pressure installation
  • Open junction, ideal for wastewater analysis
  • Ceramic junction

Glass Sensor

  • Hanna has developed four types of specialized glass. First is a durable sensor glass for general purpose, industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process and streams significantly increase the electrode life

Temperature Sensor

  • The pH electrodes with built-in 3-wire Pt100 or Pt1000 temperature sensor allow for the temperature compensation of pH readings as well as temperature measurements.

Connection Type

  • Electrodes are wired for direct connection to a transmitter or process controller, or with the standard BNC connector.

Built-in Amplifier

  • Models with a built-in amplifier are necessary for long distance measurements, where it is not possible to install a transmitter. The internal amplifier can be powered directly from select Hanna process controllers or a power source that supplies the appropriate voltage.

Cable Length

  • Non-amplified electrodes are provided with a 5, 10 or 15 m cable (16’, 33’ or 49’)

PVDF Body

  • The PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications, and guarantees a high chemical and mechanical resistance. These characteristics makes the PVDF material the most recommended for many industrial applications. PVDF is also non-toxic and compatible with food applications.

Specifications

SKU HI1006-4005
Name Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-HF – Hydrofluoric Acid Resistant-None

Manuals

Industrial Flat Tip pH Electrode with PTFE Junction – HI1006-5m (16.4′)-BNC-HF – Hydrofluoric Acid Resistant-None

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality