Holmium Oxide Glass Filter for Spectrophotometers – HI801-11

The HI801-11 is a holmium oxide glass filter that is used to validate the wavelength accuracy of the HI801 iris spectrophotometer. The filter is mounted in a 10 mm square anodized holder and comes with a protective plastic holder that protects the filter when not in use.

  • Glass filter mounted in anodized aluminum holder
  • Fits all spectrophotometers that can accommodate 10 mm square cuvette
  • Absorbance peaks measured at 361, 454, 536, and 638 nm

989.00 AED

Estimated delivery: 24 - 25 April

Inquire Now
SKU:HI801-11

Holmium is a rare earth element that is silvery white and malleable. Holmium reacts with oxygen to form holmium oxide. Glasses that contain holmium oxide or holmium oxide solution are useful in the calibration of spectrophotometers due to their sharp absorption peaks in the visible spectrum. The National Institute of Technology (N.I.S.T.), formerly National Bureau of Standards (N.B.S.) uses a holmium oxide solution sealed into silica cuvettes as the standard reference material (SRM 2034) for traceability. The holmium oxide solution is prepared with holmium oxide dissolved in perchloric acid. This solution has many well-defined absorption bands. The SRM2034 was found to be stable for up to thirty years*The HI801-11 is traceable to SRM2034 and is supplied with certificate of that identifies the peak absorbance values of the filter within 0.1 nm of uncertainty. The HI801-11 holmium oxide filter is used with the wavelength check mode found in the HI801 iris spectrophotometer. The filter is placed into the meter and the wavelength check mode is then used to verify the wavelength positioning. Once the check is complete the meter will display the wavelength peaks and they are compared to the values found on the certificate. The values should be within ±1.5 nm of the certified value.* NIST Special Publication 260-192FEATURES/BENEFITS:Holmium Oxide Filter

  • Supplied with Certificate of Analysis

    traceable to SRM2034

  • All values are certified and have an uncertainty of less than 0.1 nm
  • Packaged in light tight plastic cuvette holder

Specifications

SKUHI801-01
Nameiris Visible Spectrophotometer – HI801
pH Range6.5 to 8.5 pH
pH Resolution0.1 pH
pH Accuracy±0.1 pH
pH MethodAdaptation of the Phenol Red method
Dissolved Oxygen Range0.0 to 10.0 mg/L (as O2 )
Dissolved Oxygen Resolution0.1 mg/L
Dissolved Oxygen Accuracy±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range0.000 to 3.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
Alkalinity Range0 to 500 mg/L (as CaCO3 )
Alkalinity Resolution1 mg/L
Alkalinity Accuracy±5 mg/L ±5% of reading
Alkalinity MethodColorimetric Method
Seawater Alkalinity Range0 to 300 mg/L (as CaCO3 )
Seawater Alkalinity Resolution1 mg/L
Seawater Alkalinity Accuracy±5 mg/L ±5% of reading
Seawater Alkalinity MethodColorimetric Method
Aluminum Range0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution0.01 mg/L
Aluminum Accuracy±0.04 mg/L ±4% of reading
Aluminum MethodAdaptation of the aluminon method.
Ammonia RangeLow Range:0.00 to 3.00 mg/L (as NH3 -N)Medium Range: 0.00 to10.00 mg/L (as NH3 -N)High Range: 0.0 to 100.0 mg/L (as NH3 -N)
Ammonia ResolutionLow and Medium Range: 0.01 mg/LHigh Range: 0.1 mg/L
Ammonia AccuracyLow Range: ±0.04 mg/L ±4% of readingMedium Range: ±0.05 mg/L ±5% of readingHigh range: ±0.5 mg/L ±5% of reading
Ammonia MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
Anionic Surfactants Range0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution0.01 mg/L
Anionic Surfactants Accuracy±0.04 mg/L ±3% of reading
Anionic Surfactants MethodAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
Bromine Range0.00 to 8.00 mg/L (as Br2 )
Bromine Resolution0.01 mg/L
Bromine Accuracy±0.08 mg/L ±3% of reading
Bromine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Calcium Range0 to 400 mg/L (as Ca2+)
Calcium Resolution1 mg/L
Calcium Accuracy±10 mg/L ±5% of reading
Calcium MethodAdaptation of the Oxalate method
Carbon Dioxide Range0.00 to 2.00 mg/L (as ClO2 )
Carbon Dioxide Resolution0.01 mg/L
Carbon Dioxide Accuracy±0.10 mg/L ±5% of reading
Carbon Dioxide MethodAdaptation of the Chlorophenol Red method
Chemical Oxygen Demand RangeLow Range: 0 to 150 mg/L (as O2 )Medium Range: 0 to 1500 mg/L (as O2 )High Range: 0 to 15000 mg/L (as O2 )
Chemical Oxygen Demand Resolution1 mg/L
Chemical Oxygen Demand AccuracyLow Range: ±5 mg/L or ±4% of readingMedium Range: ±15 mg/L or ±4% of readingHigh Range: ±150 mg/L or ±2% of reading
Chemical Oxygen Demand MethodAdaptation of the USEPA 410.4
Chloride Range0.0 to 20.0 mg/L (as Cl)
Chloride Resolution0.1 mg/L
Chloride Accuracy±0.5 mg/L ±6% of reading
Chloride MethodAdaptation of the mercury(II) thiocyanate method
Chlorine Dioxide Range0.00 to 2.00 mg/L (as ClO2 )
Chlorine Dioxide Resolution0.01 mg/L
Chlorine Dioxide Accuracy±0.10 mg/L ±5% of reading
Chlorine Dioxide MethodAdaptation of the Chlorophenol Red method
Free Chlorine RangeUltra Low Range : 0.000 to 0.500 mg/L (as Cl2 )Low Range : 0.00 to 5.00 mg/L (as Cl2)High Range : 0.00 to 10.00 mg/L (as Cl2)
Free Chlorine ResolutionUltra Low Range : 0.001 mg/Low Range : 0.01 mg/LHigh Range : 0.01 mg/L
Free Chlorine AccuracyUltra Low Range : ±0.020 mg/L ±3% of readingLow Range : ±0.03 mg/L ±3% of readingHigh Range : ±0.03 mg/L ±3% of reading
Total Chlorine RangeUltra Low Range : 0.000 to 0.500 mg/L (as Cl2 )Low Range : 0.00 to 5.00 mg/L (as Cl2)High Range : 0.00 to 10.00 mg/L (as Cl2)Ultra High Range : 0 to 500 mg/L (as Cl2 )
Total Chlorine ResolutionUltra Low Range : 0.001 mg/LLow Range : 0.01 mg/LHigh Range : 0.01 mg/LUltra High Range : 1 mg/L
Total Chlorine AccuracyUltra Low Range : ±0.020 mg/L ±3% of readingLow Range : ±0.03 mg/L ±3% of readingHigh Range : ±0.03 mg/L ±3% of readingUltra High Range : ±3 mg/L ±3% of reading
Chromium, Hexavalent RangeLow Range : 0 to 300 µg/L (as Cr(VI))High Range : 0 to 1000 µg/L (as Cr(VI))
Chromium, Hexavalent ResolutionLow Range : 1 µg/LHigh Range : 1 µg/L
Chromium, Hexavalent AccuracyLow Range : ±10 µg/L ±4% of readingHigh Range : ±5 µg/L ±4% of reading at 25 °C
Chromium, Hexavalent MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method
Color, Water Range0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution1 PCU
Color, Water Accuracy±10 PCU ±5% of reading
Color, Water MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
Color, Maple Syrup Range0.00 to 100.00 %T
Color, Maple Syrup Resolution0.01 %T
Color, Maple Syrup Accuracy±3% of reading
Color, Maple Syrup MethodDirect measure
Copper RangeLow Range : 0.000 to 1.500 mg/L (as Cu)High Range : 0.00 to 5.00 mg/L (as Cu)
Copper ResolutionLow Range :0.001 mg/LHigh Range : 0.01 mg/L
Copper AccuracyLow Range : ±0.010 mg/L ±5% of readingHigh Range : ±0.02 mg/L ±4% of reading
Copper MethodAdaptation of the EPA method
Cyanide Range0.000 to 0.200 mg/L (as CN-)
Cyanide Resolution0.001 mg/L
Cyanide Accuracy±0.005 mg/L ±3% of reading
Cyanide MethodPyridine-Pyrazalone
Cyanuric Acid Range0 to 100 mg/L (as CYA)
Cyanuric Acid Resolution1 mg/L
Cyanuric Acid Accuracy±1 mg/L ±15% of reading
Cyanuric Acid MethodAdaptation of the turbidimetric method
Fluoride RangeLow Range : 0.00 to 2.00 mg/L (as F)High Range : 0.0 to 20.0 mg/L (as F)
Fluoride ResolutionLow Range : 0.01 mg/LHigh Range : 0.1 mg/L
Fluoride AccuracyLow Range : ±0.03 mg/L ±3% of readingHigh Range : ±0.5 mg/L ±3% of reading
Fluoride MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total RangeLow Range : 0 to 250 mg/L (as CaCO3 )Medium Range : 200 to 500 mg/L (as CaCO3 )High Range : 400 to 750 mg/L (as CaCO3 )
Hardness, Total Resolution1 mg/L
Hardness, Total AccuracyLow Range : ±5 mg/L ±4% of readingMedium Range : ±7 mg/L ±3% of readingHigh Range : ±10 mg/L ±2% of reading
Hardness, Total MethodAdaptation of the EPA recommended method 130.1
Hardness, Calcium Range0.00 to 2.70 mg/L (as CaCO3 )
Hardness, Calcium Resolution0.01 mg/L
Hardness, Calcium Accuracy±0.11 mg/L ±5% of reading
Hardness, Calcium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range0.00 to 2.00 mg/L (CaCO3 )
Hardness, Magnesium Resolution0.01 mg/L
Hardness, Magnesium Accuracy±0.11 mg/L ±5% of reading
Hardness, Magnesium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range0 to 400 µg/L (as N2H4 )
Hydrazine Resolution1 µg/L
Hydrazine Accuracy±4% of full scale reading
Hydrazine MethodAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
Iodine Range0.0 to 12.5 mg/L (as I2 )
Iodine Resolution0.1 mg/L
Iodine Accuracy±0.1 mg/L ±5% of reading
Iodine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron RangeLow Range : 0.000 to 1.600 mg/L (as Fe)High Range : 0.00 to 5.00 mg/L (as Fe)
Iron ResolutionLow Range : 0.001 mg/LHigh Range : 0.01 mg/L
Iron AccuracyLow Range : ±0.010 mg/L ±8% of readingHigh Range : ±0.04 mg/L ±2% of reading
Iron MethodLow Range : Adaptation of the TPTZ MethodHigh Range : Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
Magnesium Range0 to 150 mg/L (as Mg2+)
Magnesium Resolution1 mg/L
Magnesium Accuracy±5 mg/L ±3% of reading
Magnesium MethodAdaptation of the Calmagite method
Manganese RangeLow Range : 0 to 300 µg/L (as Mn)High Range : 0.0 to 20.0 mg/L (as Mn)
Manganese ResolutionLow Range : 1 µg/LHigh Range : 0.1 mg/L
Manganese AccuracyLow Range : ±10 µg/L ±3% of readingHigh Range : ±0.2 mg/L ±3% of reading
Manganese MethodLow Range : Adaptation of the PAN MethodHigh Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
Molybdenum Range0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution0.1 mg/L
Molybdenum Accuracy±0.3 mg/L ±5% of reading
Molybdenum MethodAdaptation of the mercaptoacetic acid method
Nickel RangeLow Range : 0.000 to 1.000 mg/L (as Ni)High Range : 0.00 to 7.00 g/L (as Ni)
Nickel ResolutionLow Range : 0.001 mg/LHigh Range : 0.01 g/L
Nickel AccuracyLow Range : ±0.010 mg/L ±7% of readingHigh Range : ±0.07g/L ±4% of reading
Nickel MethodLow Range : Adaptation of the PAN methodHigh Range : Adaptation of the photometric method
Nitrate Range0.0 to 30.0 mg/L (as NO3 – N)Chromotropic Acid : 0.0 to 30.0 mg/L (as N03–N)
Nitrate Resolution0.1 mg/L
Nitrate Accuracy±0.5 mg/L ±10% of readingChromotropic Acid : ±1.0 mg/L or ±3% of reading
Nitrate MethodAdaptation of the cadmium reduction methodChromotropic Acid : Chromotropic acid method
Nitrite RangeMarine Ultra Low Range : 0 to 200 µg/L (as N02 -N)Low Range : 0 to 600 µg/L (as NO2 -N)High Range : 0 to 150 mg/L (as NO2-)
Nitrite ResolutionMarine Ultra Low Range : 1 µg/LLow Range : 1 µg/LHigh Range : 1 mg/L
Nitrite AccuracyMarine Ultra Low Range : ±10 µg/L ±4% of readingLow Range : ±20 µg/L ±4% of readingHigh Range : ±4 mg/L ±4% of reading
Nitrite MethodMarine Ultra Low Range : Adaptation of the EPA Diazotization method 354.1Low Range : Adaptation of the EPA Diazotization method 354.1High Range : Adaptation of the Ferrous Sulfate method
Nitrogen, Total RangeLow Range : 0.0 to 25.0 mg/L (as N)High Range : 10 to 150 mg/L (as N)
Nitrogen, Total ResolutionLow Range : 0.1 mg/LHigh Range : 1 mg/L
Nitrogen, Total AccuracyLow Range : ±1.0 mg/L or ±5% of readingHigh Range : ±3 mg/L or ±4% of reading
Nitrogen, Total MethodChromotropic acid method
Oxygen, Scavenger RangeCarbohydrazide : 0.00 to 1.50 mg/L (as Carbohydrazide)Diethylhydroxylamine)(DEHA) : 0 to 1000 µg/L (as DEHA)Hydroquinone : 0.00 to 2.50 mg/L (as Hydroquinone)Iso-ascorbic Acid :0.00 to 4.50 mg/L (as Iso-ascorbic acid)
Oxygen, Scavenger ResolutionCarbohydrazide : 0.01 mg/LDiethylhydroxylamine)(DEHA) : 1 µg/LHydroquinone : 0.01 mg/LIso-ascorbic Acid : 0.01 mg/L
Oxygen, Scavenger AccuracyCarbohydrazide : ±0.02 mg/L ±3% of readingDiethylhydroxylamine)(DEHA) : ±5 µg/L ±5% of readingHydroquinone : ±0.04 mg/L ±3% of readingIso-ascorbic Acid : ±0.03 mg/L ±3 % of reading
Oxygen, Scavenger MethodAdaptation of the iron reduction method
Ozone Range0.00 to 2.00 mg/L (as O3 )
Ozone Resolution0.01 mg/L
Ozone Accuracy±0.02 mg/L ±3% of reading
Ozone MethodColorimetric DPD Method
Phosphate RangeLow Range : 0.00 to 2.50 mg/L (as PO4 3-)High Range : 0.0 to 30.0 mg/L (as PO4 3-)
Phosphate ResolutionLow Range : 0.01 mg/LHigh Range : 0.1 mg/L
Phosphate AccuracyLow Range : ±0.04 mg/L ±4% of readingHigh Range : ±1.0 mg/L ±4% of reading
Phosphate MethodLow Range : Adaptation of the Ascorbic Acid methodHigh Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
Phosphorous, Acid Hydrolyzable Range0.00 to 1.60 mg/L (as P)
Phosphorous, Acid Hydrolyzable Resolution0.01 mg/L
Phosphorous, Acid Hydrolyzable Accuracy±0.05 mg/L or ±5% of reading
Phosphorous, Acid Hydrolyzable MethodAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Reactive RangeLow Range : 0.00 to 1.60 mg/L (as P)High Range : 0.0 to 32.6 mg/L (as P)
Phosphorous, Reactive ResolutionLow Range : 0.01 mg/LHigh Range : 0.1 mg/L
Phosphorous, Reactive AccuracyLow Range : ±0.05 mg/L or ±4% of readingHigh Range : ±0.5 mg/L or ±4% of reading
Phosphorous, Reactive MethodAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Total RangeLow Range : 0.00 to 1.15 mg/L (as P)High Range : 0.0 to 32.6 mg/L (as P)
Phosphorous, Total AccuracyLow Range : 0.01 mg/LHigh Range : 0.1 mg/L
Phosphorous, Total ResolutionLow Range : ±0.05 mg/L or ±6% of readingHigh Range : ±0.5 mg/L or ±5% of reading
Phosphorous, Total MethodLow Range : Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.High Range : Adaptation of the Standard Methods for the Examination of Water and Wastewate
Potassium RangeLow Range : 0.0 to 20.0 mg/L (as K)Medium Range : 10 to 100 mg/L (as K)High Range : 20 to 200 mg/L (as K)
Potassium ResolutionLow Range : 0.1 mg/LMedium Range : 1 mg/LHigh Range : 1 mg/L
Potassium AccuracyLow Range : ±2 mg/L ±7% of readingMedium Range : ±10 mg/L ±7% of readingHigh Range : ±20 mg/L ±7% of reading
Potassium MethodAdaptation of the Turbidimetric Tetraphenylborate method
Silica RangeLow Range : 0.00 to 2.00 mg/L (as SiO2 )High Range : 0 to 200 mg/L (as SiO2 )
Silica ResolutionLow Range : 0.01 mg/LHigh Range : 1 mg/L
Silica AccuracyLow Range : ±0.03 mg/L ±3% of readingHigh Range : ±1 mg/L ±5% of reading
Silica MethodLow Range : Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue methodHigh Range : Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and
Silver Range0.000 to 1.000 mg/L (as Ag)
Silver Resolution0.001 mg/L
Silver Accuracy±0.020 mg/L ±5% of reading
Silver MethodAdaptation of the PAN method
Sulfate Range0 to 150 mg/L (as SO42-)
Sulfate Resolution1 mg/L
Sulfate Accuracy±5 mg/L ±3% of reading
Sulfate MethodSulfate is precipitated with barium chloride crystals
Zinc Range0.00 to 3.00 mg/L (as Zn)
Zinc Resolution0.01 mg/L
Zinc Accuracy±0.03 mg/L ±3% of reading
Zinc MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Wavelength Range340 to 900 nm
Wavelength Resolution1 nm
Wavelength Accuracy±1.5 nm
Measurement ModesTransmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit)
Wavelength Selectionautomatic, based on the selected method (editable for user methods only)
Optical Systemsplit beam sample and reference light detectors
Wavelength Calibrationinternal, automatic at power-on, visual feedback
Data Points Storedup to 9999 measured values
Export Capability.csv file format, .pdf file format
Connectivity(1) USB – A (mass storage host); (1) USB – B (mass storage device)
Power Supply15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Battery Type/Life3000 measurements or 8 hours
Environment0 to 50 °C (32 to 122 °F); 0 to 95% RH
Weight3 kg (6.6 lbs)
Dimensions155 x 205 x 322 mm (6.1 x 8.0 x 12.6*rdquo;)

Ordering Info

HI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.

Manuals

https://manuals.hannainst.com/HI801-01

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

510.00 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector