Out of stock

High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51

The HI84530 Titratable Acidity for Water Analysis utilizes two different titrant solutions depending on the selected range when measuring acidity in water.The HI84530-51 is a 120 mL bottle of high range titrant with an expected range between 300 to 4000 mg/L as CaCO3. The titrant solution is pre-standardized, making titrations fast, accurate, and easy to perform.

  • Pre-standardized titrant
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

122 AED

Estimated delivery: 18 - 19 September

Inquire Now
SKU:HI84530-51

The HI84530-51 is a 120 mL bottle of alkaline titrant solution that is used for high range (300 to 4000 mg/L as CaCO3) determination of acidity in water.The HI84530 mini titrator is designed to determine the acidity of waters by potentiometric titration in both a low range (15 to 400 mg/L as CaCO3) and high range (300 to 4000 mg/L as CaCO3). Both total and strong acidity can be determined by the HI84530. If the measured pH is lower than 3.7 both total and strong acidity can be determined. If the sample is greater than pH 3.7 then only total acidity can be determined.The endpoint of an acid base titration corresponds to the complete neutralization of the acids present. Water acidity results from strong and weak acids as well as from the hydrolysis of salts. Due to these more complex mixtures, endpoints for water acidity are arbitrarily fixed on practical considerations. Unpolluted surface waters contain carbon dioxide as the main acidic component, and titration of these samples corresponds to the stoichiometric neutralization of carbonic acid with sodium hydroxide. The titration to pH 8.3 represents total acidity. The titration to pH 3.7 represents strong acidity from polluted water. If the samples are suspected to contain hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese), it is necessary to pretreat the samples with HI84530-60 reagent.

Replacement reagents required to operate the HI84530 include:

Low Range – 15 to 400 mg/L as CaCO3 High Range – 300 to 4000 mg/L as CaCO3
Pump calibration standard HI84530-55 HI84530-55
Titrant solution HI84530-50 HI84530-51
Hydrogen peroxide reagent* HI84530-60 HI84530-60

* Used with samples containing hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese)

Specifications

SKU HI84530-51
Name High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51
Description High Range Titrant for Titratable Acidity in Water Mini Titrator
Package bottle
Quantity 1
Size 120 mL

Manuals

High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51

Bestsellers

Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

932 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.
Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

288 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
Inquire Now

® Multiparameter EC/TDS/Salinity Meter - HI2030

2,530 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.
Inquire Now

pH Electrode for Beer Analysis - FC2143

681 AED
The FC2143 is a titanium body, gel filled, single reference junction pH electrode. This electrode features low temperature glass and an extendable cloth type junction, along with a built-in temperature sensor and amplifier in a single probe design. This design consideration is ideal for measuring the pH of mash or wort during the beer making process. The FC2143 is the replacement pH/temperature probe supplied with the HI99151 portable meter for beer.
  • Low Temperature Glass
  • Titanium Body
  • Built-in Temperature Sensor
Inquire Now

pH Electrode with Clogging Prevention System (CPS™) and BNC Connector - HI1048B

823 AED
The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
  • Clogging Prevention System (CPS™) Technology
  • Refillable Electrode
  • Double Junction Design
Inquire Now

® Multiparameter pH Meter - HI2020

1,693 AED
edge® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with a simplified menu and options. For those who require advanced features there is the full featured standard operating mode. The edge HI2020 pH kit can be upgraded at any time with additional probes to measure Conductivity or Dissolved Oxygen.

HI12883 pH/EC/TDS Multiparameter Probe with Quick Connect DIN Connector

583 AED
The HI12883 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance free polymer gel electrolyte, and a low temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two graphite sensors for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI12883 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatemnt and boilers and cooling towers. The HI12883 is designed for use with Hanna’s HI991300 and HI991301 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor
Back to Top
Whatsapp
Product has been added to your cart