Out of stock

High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51

The HI84530 Titratable Acidity for Water Analysis utilizes two different titrant solutions depending on the selected range when measuring acidity in water.The HI84530-51 is a 120 mL bottle of high range titrant with an expected range between 300 to 4000 mg/L as CaCO3. The titrant solution is pre-standardized, making titrations fast, accurate, and easy to perform.

  • Pre-standardized titrant
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

130.00 AED

Inquire Now
SKU:HI84530-51

The HI84530-51 is a 120 mL bottle of alkaline titrant solution that is used for high range (300 to 4000 mg/L as CaCO3) determination of acidity in water.The HI84530 mini titrator is designed to determine the acidity of waters by potentiometric titration in both a low range (15 to 400 mg/L as CaCO3) and high range (300 to 4000 mg/L as CaCO3). Both total and strong acidity can be determined by the HI84530. If the measured pH is lower than 3.7 both total and strong acidity can be determined. If the sample is greater than pH 3.7 then only total acidity can be determined.The endpoint of an acid base titration corresponds to the complete neutralization of the acids present. Water acidity results from strong and weak acids as well as from the hydrolysis of salts. Due to these more complex mixtures, endpoints for water acidity are arbitrarily fixed on practical considerations. Unpolluted surface waters contain carbon dioxide as the main acidic component, and titration of these samples corresponds to the stoichiometric neutralization of carbonic acid with sodium hydroxide. The titration to pH 8.3 represents total acidity. The titration to pH 3.7 represents strong acidity from polluted water. If the samples are suspected to contain hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese), it is necessary to pretreat the samples with HI84530-60 reagent.

Replacement reagents required to operate the HI84530 include:

Low Range – 15 to 400 mg/L as CaCO3 High Range – 300 to 4000 mg/L as CaCO3
Pump calibration standard HI84530-55 HI84530-55
Titrant solution HI84530-50 HI84530-51
Hydrogen peroxide reagent* HI84530-60 HI84530-60

* Used with samples containing hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese)

Specifications

SKU HI84530-51
Name High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51
Description High Range Titrant for Titratable Acidity in Water Mini Titrator
Package bottle
Quantity 1
Size 120 mL

Manuals

High Range Titrant for Titratable Acidity in Water Mini Titrator – HI84530-51

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top