Out of stock

HI993310 Direct Soil Activity and Solution Conductivity Measurement Kit

The HI993310 is a rugged, portable meter that has been designed to address the need for fast and accurate conductivity measurements in liquids and soils. The HI993310 directly measures soil solution conductivity in EC (mS/cm) as well as soil activity (g/L). It is supplied with two probes: HI76305 with stainless steel, conical tip for direct soil measurement and HI76304 for fertilizer enriched solutions.

  • Two measurement modes
  • LED Alarm
  • Automatic Temperature Compensation

2,084.00 AED

Inquire Now
SKU:HI993310

The soil activity and conductivity of nutritive solutions, irrigation water, and saturated soil-paste are two important parameters for growers and horticulturists. With HI993310 it is possible to directly measure, in a quick and simple way, the soil activity in the ground as well as the conductivity of various solutions.

The portable HI993310 meter measures the soil conductivity in EC (mS/cm) as well as soil activity (g/L). These two measurement modes are made possible using the two supplied probes: HI76305 with stainless steel, conical tip for direct soil measurement and HI76304 for fertilizer enriched solutions. The two different scales can be selected through two keys on the front panel and two separate LEDs indicate which parameter is being tested. In addition, HI993310 is equipped with an alarm LED that illuminates if the soil is too dry or nutritive substances such as potassium or nitrogen are lacking.

Features at-a-glance

Two Probes – The HI76305 is a stainless steel EC probe that features a conical tip and internal temperature sensor to allow for accurate, direct, and temperature compensated measurements of soil activity in g/L. The HI76304 is a durable, two-ting EC probe that features an internal temperature sensor to allow measurement in nutritive solutions, irrigation water, or soil slurries.

Two Measurement Modes – HI993310 offers two measurement modes: EC and soil activity. Users can easily switch between measurement modes with the simple press of a button. The “W” button on the meter face automatically switches to water conductivity measurement mode in units of mS/cm. The “S” button switches to soil activity measurement mode in units of g/L. EC measurements range from 0.00 to 19.99 mS/cm; soil activity measurements range from 0.00 to 1.00 g/L.

Automatic Temperature Compensation – Since temperature has such a dramatic effect on conductivity readings, having a meter that offers temperature compensated readings is invaluable. Both probes that come with the HI993310 feature a built-in temperature sensor that automatically accounts for the effects of temperature in the range of 0 to 50℃ (32 to 122℉).

Temperature Compensation Coefficient – The temperature compensation coefficient, also known as β, is set at 2%/℃; this factor corrects the readings for EC and soil activity 2% for each degree Celsius change in the sample.

One-point Calibration – The HI993310 can be calibrated at one point in a standard calibration solution. The calibration trimmer located on the face of the meter is easily adjusted to the correct calibration standard.

LED Alarm – The meter provides for a LED alarm when measuring soil activity. If the LED lights up, the soil is too dry for a proper measurement or it lacks nutritive substances. If the alarm LED lights up again after users wet the soil and carry out the measurement again, the soil lacks nutritive elements and an accurate reading cannot be taken.

Auto Shut-off – Automatic shut-off after 2 minutes of non-use when the meter is in measurement mode. This prevents wastage of batteries in the event the meter is accidentally left on.

Battery Error Prevention System (BEPS) – The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.

Specifications

SKU HI993310
Name HI993310 Direct Soil Activity and Solution Conductivity Measurement Kit
EC Range 0.00 to 19.99 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% FS
EC Calibration Manual, single-point through knob
EC/TDS Temperature Compensation automatic from 0 to 50°C (32 to 122°F) with β=2%/°C typical
Soil Activity Range 0.00 to 1.00 g/L
Soil Activity Resolution 0.01 g/L
Soil Activity Accuracy ±2% FS
EC/TDS Probe HI76304 plastic body, ATC, conductivity probe with 1 m (3.3’) cable
Soil Activity Probe HI76305 stainless steel conic tip, ATC probe for direct soil meas. with 1 m (3.3’) cable
Automatic Shut-Off auto-off after 2 minutes of non-use
Battery Type/Life 9V / approximately 100 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 185 x 82 x 52 mm (7.3 x 3.2 x 2.0”)
Weight 275 g (9.7 oz)

Ordering Info

HI993310 is supplied with HI76304 conductivity probe, HI76305 direct soil conductivity probe, battery, instruction manual, and rugged carrying case.

Manuals

HI993310 Direct Soil Activity and Solution Conductivity Measurement Kit

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal