Out of stock

HI97105 Marine Master Multiparameter Photometer-meter only

The HI97105 Marine Master Photometer combines accuracy and ease of use in a simple, portable design. The advanced optical system provides lab-quality accuracy while its user-friendly design is easy for any aquarium user making it the perfect photometer for your water quality testing needs. The HI97105 is designed to accurately determine pH, Alkalinity, Calcium, Nitrate, Nitrite, and Phosphate level in aquariums and marine biology applications.

  • No warm up time needed before taking a measurement.
  • Tutorial mode for easy step-by-step instructions.
  • CAL Check™ for performance verification and calibration.

Inquire Now
SKU:HI97105-meter only

Better Features for Better Testing

Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.

The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.

When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.

Data Logging

Missed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.

CAL Check™ Validation

Hanna’s exclusive CAL Check™ feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check™ standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.

HI97105_Positive-Locking-System-5770x5686-f322d082-9b20-4f41-a47c-508fcc3f33f7

Advanced Optical System

A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.

Built Better

Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive‑locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.

Portable Design

Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.

We believe that buying a meter should be simple. Your HI97105 photometer has many of the necessary accessories needed for successful measurements.

Each HI97105 is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cap (2 pcs.)
  • Plastic stopper (2 pcs.)
  • Alkaline batteries: 1.5V AA (3 pcs.)
  • Instruction manual
  • Meter quality certificate

Upgrade to the Marine Master Photometer Kit (includes the CAL Check™ Standards) for the most economical option for testing.

Each HI97105C is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cuvette cap (2 pcs.)
  • Marine pH reagent, 30 mL dropper (1 pc.)
  • Marine Alkalinity reagent, 30 mL (1 pc.)
  • Marine Calcium reagent A, 30 mL (1 pc.)
  • Marine Calcium reagent B starter kit (reagent for 25 tests)
  • Marine Nitrate High Range starter kit (reagent for 25 tests)
  • Marine Nitrite Ultra Low Range starter kit (reagent for 25 tests)
  • Marine Phosphate Ultra Low Range starter kit (reagent for 25 tests)
  • 1 mL graduated syringe with tip (2 pcs.)
  • Minipipette with tip (1 pc.)
  • 3 mL Pasteur pipette (2 pcs.)
  • 1.5V AA Alkaline batteries (3 pcs.)
  • Cloth for wiping cuvettes
  • Scissors
  • Instrument quality certificate
  • Instruction manual

Specifications

SKU HI97105-meter only
Name HI97105 Marine Master Multiparameter Photometer-meter only
Marine pH Range 6.3 to 8.6 pH
Marine pH Resolution 0.1 pH
Marine pH Accuracy ±0.2 pH of reading at 25 °C
Marine pH Method adaptation of the phenol red method
Marine Alkalinity Range 0.0 to 20.0 dkH; 0 to 357 ppm (as CaCO3)
Marine Alkalinity Resolution 1 dkH
Marine Alkalinity Accuracy ±0.3 dkH; ±5 ppm of reading at 25 °C
Marine Alkalinity Method colorimetric method
Marine Calcium Range 200 to 600 ppm
Marine Calcium Resolution 1 ppm
Marine Calcium Accuracy ±6% of reading at 25 °C
Marine Calcium Method adaptation of the zincon method
Marine Nitrate LR Range 0.00 to 5.00 mg/L (as NO3 )
Marine Nitrate LR Resolution 0.01 ppm
Marine Nitrate LR Accuracy ±0.25 ppm ±2% of reading at 25 °C
Marine Nitrate LR Method colorimetric
Marine Nitrate HR Range 0.0 to 75.0 ppm (as NO3)
Marine Nitrate HR Resolution 0.1 ppm
Marine Nitrate HR Accuracy ±2.0 ppm ±5% of reading at 25 °C
Marine Nitrate HR Method zinc reduction method
Marine Nitrite ULR Range 0 to 200 ppb (as NO2-N)
Marine Nitrite ULR Resolution 1 ppb
Marine Nitrite ULR Accuracy ±10 ppb ±4% of reading at 25 °C
Marine Nitrite ULR Method Adaptation of the EPA Diazotization method 354.1
Marine Phosphate ULR Range 0.00 to 0.9 ppm
Marine Phosphate ULR Resolution 0.01 ppm
Marine Phosphate ULR Accuracy ±0.02 ppm ±5% of reading at 25 °C
Marine Phosphate ULR Method adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Method
Photometer/Colorimeter Light Source light emitting diode
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 525 nm and 610 nm
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type round 24.6 mm diameter (22 mm inside)
Light Detector silicon photocell
Display 128 x 64 pixel B/W LCD with backlight
Auto logging 200 readings
Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH
Case IP67 rating, floating case
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)

Manuals

HI97105 Marine Master Multiparameter Photometer-meter only

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top