In stock

HI763100 – Digital EC/Temperature Electrode

The HI 763100 is a digital conductivity electrode with a built-in temperature sensor. Compared to the amperometric design of other conductivity probes, the HI 763100 is potentiometric probe with platinum sensors which allows for the possibility to measure high or low conductivity ranges using one probe. This electrode features an integrated microchip which stores calibration data, electrode type, and serial number. The HI 763100 is designed for use with Hanna’s edge® pH/EC/DO meter.

  • Digital Probe with Built-in Microchip
  • Internal Temperature Sensor
  • 3.5 mm Connector

1,551.00 AED

Estimated delivery: 22 - 23 September

SKU:HI763100
digital electrode

Built-in Microchip

The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.

digital electrode

Potentiometric Measuring System

The four ring potentiometric measuring system allows measurement of a broad range of samples while minimizing the effects of polarization. The two outer rings apply and alternating voltage and induce a current loop in the solution, while the two inner rings measure the voltage drop induced by the current loops. This allows for a range of readings from very high to very low without changing electrodes.

digital electrode

Sleeve

The probe is surrounded by a chemically resistant plastic sleeve to maintain control external interferences from the sample. It also allows the current loop to be generated in a controlled area.

digital electrode

Internal Temperature Sensor

Since temperature is an important factor for measuring conductivity, a built in temperature sensor on the probe is very helpful. There is no need for an external temperature probe, so that measurements can be made easily. The coefficient used to correct for changes in temperature is β, which is expressed as a percentage of reading per degree of Celsius.

Features at-a-glance

  • Digital, microprocessor based – no high impedance signal to the meter
  • Potentiometric measuring system- suitable over a wide range of conductivities
  • Built-in temperature sensor – no need for an additional temperature probe
  • 3.5mm digital plug – easy to plug in, no alignment necessary
  • PEI body – highly durable and well-suited for field applications

Specifications

SKU HI763100
Name HI763100 – Digital EC/Temperature Electrode
Measurement Range EC: 0 to 200 mS/cm
Body Material PEI
Tip / Shape Platinum/4-ring
Temperature Operating Range -5 to 100°C (23 to 212°F)
Body Length/Overall Length 120mm
Temperature Sensor yes
Cable 1 m (3.3 in.)
Amplifier no
Notes Insulator: glass
Compatible Meters edge multiparameter

Manuals

HI763100 – Digital EC/Temperature Electrode

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart