In stock

HI1288 pH/EC/TDS Multiparameter Probe

The HI1288 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance free polymer gel electrolyte, and a low temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two graphite sensors for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1288 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatement and boilers and cooling towers. The HI1288 is designed for use with Hanna’s HI991300 and HI991301 portable multiparameter meters.

  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

592.00 AED

Estimated delivery: 2 - 3 December

SKU:HI1288

Hanna Instruments offers a wide variety of electrodes that are designed for many different applications. The sensing material, body material, and connection type used are just some of the design considerations.

hi1288 electrode

Pre-Amplified pH Electrode

The pH electrode circuit has a built-in amplifier that serves to reduce the effects of electrical noise on the high impedance pH measurement. Electrical noise can come from motors and pumps that are common in greenhouses. The single reference junction design of the pH electrode has a cloth junction that allows ion movement between the inner gel electrolyte and the sample being measured. The advantage of the cloth junction is that it can be extracted from the probe, exposing a fresh surface when readings become drifty or erratic. These features make this probe ideal for use in fertilizer solutions.

Amperometric EC/TDS Sensor

EC/TDS readings are performed by a two-pin amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins determines the amount of dissolved ionic solids present.

Built-In Temperature Sensor

pH and EC/TDS readings must be temperature compensated in order to obtain accurate results. The built-in temperature sensor of the HI1288 provides a speedy temperature reading which is then used to adjust the pH and EC/TDS results accordingly.

Polypropylene Body

The polypropylene body of the HI1288 houses all three sensors within a sturdy, single body design. This body material is suitable for a wide range of applications and excels in measurements with portable meters due to its durability. The fins around the spherical glass pH bulb minimizes breakage due to accidental bumping or dropping of the electrode. The polypropylene plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.

DIN Connector

The HI1288 uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI1288 is made for use with Hanna’s HI991300 and HI991301 portable multiparameter meters.

Specifications

SKU HI1288
Name HI1288 pH/EC/TDS Multiparameter Probe
Reference Cell Type HI1288
Junction Type/Flow Rate cloth
Type of Electrolyte gel
Body Material polypropylene
Glass Type LT
Tip / Shape spheric (8 mm)
Matching Pin no
Max. Pressure 0.1 bar
Optimum pH Range 0 to 13
Temperature Operating Range 0 to 50°C (32 to 122°F)
Body Length/Overall Length 95 mm / 185 mm
Temperature Sensor yes
Outer Diameter 16 mm
Cable 7-pole; 1 m (3.3 in.)
Connector Type DIN
Amplifier yes
Recommended Use General purpose, water treatment, agriculture, boilers, cooling towers
Notes To be used with HI991300 and HI991301

Manuals

HI1288 pH/EC/TDS Multiparameter Probe

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

pH/EC/TDS Multiparameter Probe - HI1285-51

491.00 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples.The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

491.00 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Back to Top
Whatsapp
Product has been added to your cart