Out of stock

HI1217D Gel pH Electrode With Din connector

Gel pH Electrode With Din connector. The HI-1217D is a general purpose pH electrode with a 1m cable and DIN connector. Recommended for use with the HI-8314 pH meter.

618.00 AED

Inquire Now
SKU:HI1217D

General Purpose pH Electrode

The HI-1217D is a general purpose pH electrode for the HI-8314 and HI-9210N.

This electrode has a 1m cable and DIN connector.

Tips for the most accurate measurements

Keep electrode hydrated

Ideally, pH electrodes should be kept in a storage solution when not in use. Placing the electrode in a small glass filled with storage solution is suitable. An option for pocket meters is to place a small piece of sponge into the meter?s cap and pour storage solution (HI-70300) into the cap to wet the sponge. Alternatively, purchase HI-740200 specialised electrode caps for storage. Pouring off any excess solution beforehand, the cap can then be placed on the meter.

Clean electrodes before use

Clean the junction of your electrodes once a day or at least once a week to prevent junction clogging and to maintain accuracy. Immerse the electrode in the proper cleaning solution for at least 15 to 20 minutes. Hanna offers a wide range of cleaning solutions for general purpose and specific applications.

Replace electrode once a year

If your electrode takes too long to stabilise a reading, or readings fluctuate wildly, it is most likely time to replace the electrode. The typical life span of any pH electrode is from 6 months to 1.5 years.

Specifications

SKU HI1217D
Reference Single,
Ag/AgCl
Junction Ceramic,
single
Connector DIN
Electrolyte gel
Max
Pressure
2
bar
Range 0
to 13 pH; @ 0 to 70°C
Tip
Shape
spheric (dia:
5.0mm)
Temperature
Sensor
yes
Amplifier yes
Body
Material
PEI
Cable coaxial;
1 m (3.3′)
Recommended
Use
general
purpose

Bestsellers

HI731336N Caps for Glass Cuvette Used with HI977 Series Portable Photometers (4 pcs)

59.00 AED
The HI731336N are the replacement caps that screw on the glass cuvettes used with the HI977xx series portable photometers. Each cap has a locking indexing tab that ensures the cuvette is inserted into the photometer in the same position. The caps are also used to block any light that would interfere with the optically based measurement. The HI731336N includes 4 caps.
  • Locking index tab for proper alignment in the photometer
  • Light blocking to prevent stray light from entering
Inquire Now

HI1217D Gel pH Electrode With Din connector

618.00 AED
Gel pH Electrode With Din connector. The HI-1217D is a general purpose pH electrode with a 1m cable and DIN connector. Recommended for use with the HI-8314 pH meter.
Inquire Now

Overhead stirrer assembly for HI931 & HI932 titrator

HI930301 is a replacement overhead stirrer (includes overhead stirrer and 3 propellers) for the HI931 and HI932 Automatic Potentiometric Titrators.

HI76510-50 Detachable Probe cable, 50 m (164 ft)

6,367.00 AED
HI76510-50 Detachable Probe cable, 50 m (164 ft)

HI2002/3 Flow-Thru Monitoring Process Controller ORP Electrode with Platinum Sensor

714.00 AED
Flow-thru monitoring ORP electrode, platinum sensor, with BNC connection and 3 m cable.
Inquire Now

HI740034P Cap for 100mL Plastic Beaker (10 pcs)

71.00 AED
The HI740034P is the matching set of plastic caps for use with the HI740036P plastic beakers used with Hanna test kits and various meters.
  • Durable plastic
  • Set contains 10 pieces
  • For use with HI740036P plastic beakers
Back to Top
Whatsapp
Product has been added to your cart