Out of stock

GroLine Waterproof pH Tester with 0.01 Resolution – HI98118

groline hydroponics ph ec ppm meter

The GroLine HI98118 pH/temperature tester measures the pH of a hydroponic nutrient solution, essential to maximize optimum growth.  The table below lists the ideal pH range for a variety of plants. The HI98118 can also measure the pH in soil slurries or soils and nutrient solutions using the  Pour Through Sampling Method for container plants, where leachate is collected from a thoroughly watered plant for testing.

  • Two-Button Operation
  • Quick Calibration Mode using Hanna Quick Cal pH/EC Calibration Solution
  • Extractable Cloth Junction to Extend pH Electrode Life

263.00 AED

Inquire Now
SKU:HI98118

Features

Automatic Temperature Compensation (ATC), displays temperature in ℃ or ℉

Renewable junction to clear any clogging that causes readings to drift and be erratic

Waterproof and designed to float if dropped in water

Automatic calibration to one or two points

Uses Hanna’s Quick Cal pH/EC standard with a pH value of 6.86 that can also be used to calibrate conductivity meters to 5, 000 µS/cm

Automatic shut-off with three user controlled settings

Large LCD displays stability indicator, low-battery indicator, and calibration tags

Optimum pH Levels for Plants

Vegetable Plants Optimal pH
Garden/Flower Plants Optimal pH
Orchard Plants Optimal pH 
Artichoke 6.5-7.5 Acacia 6-8 Apple 5-6.5
Asparagus 6-8 Acanthus 6-7 Apricot 6-7
Barley 6-7 Amaranth 6-6.5 Apricot 6-7
Bean 6-7.5 Bougainvillea 5.5-7.5 Cherry 6-7.5
Brussels Sprout 6-7.5 Dahlia 6-7.5 Grapefruit 6-7.5
Corn (Maize) 6-7.5 Erica 4.5-6 Grapevine 6-7
Cucumber 5.5-7.5 Euphorbia 6-7 Lemon 6-7
Early carrot 5.5-7 Fuchsia 5.5-7.5 Nectarine 6-7.5
Early Potato 4.5-6 Gentian 5-7.5 Orange 5-7
Egg Plant 5.5-7 Gladiolus 6-7 Peach 6-7.5
Late carrot 5.5-7 Hellebore 6-7.5 Pear 6-7.5
Late Potato 4.5-6 Hyacinth 6.5-7.5 Plum 6-7.5
Lettuce 6-7 Iris 5-6.5 Pomegranate 5.5-6.5
Melon 5.5-6.5 Juniper 5-6.5 Walnut 6-8
Oat 6-7 Ligustrum 5-7.5
Onion 6-7 Magnolia 5-6
Pea 6-7.5 Narcissus 6-8.5
Pepper 6-7 Oleander 6-7.5
Pumpkin 5.5-7.5 Paulownia 6-8
Rice 5-6.5 Portulaca 5.5-7.5
Soybean 5.5-6.5 Primula 6-7.5
Spinach 6-7.5 Rhododendron  4.5-6
Strawberry 5-7.5 Roses 5.5-7
String Beans 6-7.5 Sedum 6-7.5
Sugar beet 6-7 Sunflower 6-7
Sunflower 6-7.5 Tulip 6-7
Sweet Potato 5.5-6 Viola 5.5-6.5
Tomato 5.5-6.5
Watermelon 5.5-6.5
Wheat 6-7

Bestsellers

Chemstock for Chemicals Alcohol Ethyl (Ethanol) 99.9% Pure 3.78 litre (1 gal)

Original price was: 55.00 AED.Current price is: 40.00 AED.
  • Protects you and your family from all kinds of Viruses
  • Designed to perfection
  • Can be used for disinfecting and sanitizing all surfaces including table tops, handles, mobile phones
  • Liquid Level Indicator is provided on the can to help with measurement. Double Seal Packing to prevent any accidental leaks

Chemstock for Chemicals Sanitizing Alcohol Isopropyl Pure 1 Gal (3.78L)

Original price was: 57.00 AED.Current price is: 40.00 AED.
  • Isopropyl Alcohol 99.9percent is supplied in 1 gallon plastic bottles for easy handling.
  • The product is specified to 99.9percent purity minimum with no other contamination which ensures that it can be safely utilized as a disinfectant and sanitizing of surfaces, devices, hands, etc. or as an antiseptic.
  • Water Max. - 0.05percent, Relative density - 0.790 - 0.793. This product is strictly not to be used for potable consumption
  • SPECIFICATION: Appearance - Clear and colorless liquid, Minimum Assay (GC) - 99.9percent

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range Checker® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart