In stock

GroLine Waterproof EC/TDS Tester – HI98318

HI98318 is our latest pocket meter for measuring the EC/TDS of a hydroponic nutrient solution. This modern looking meter is only 0.7″ thick and extremely ergonomic, fitting comfortably in your hand. The HI98318 has a very large easy to read LCD display that shows both EC or TDS and temperature along with calibration, stability and low battery indicators. All operations are simplified to two buttons. One is for turning the meter on/off and the other for automatic one point calibration.

  • Graphite Sensor for Reduced Polarization Effect
  • Two-Button Operation
  • Quick Calibration Mode using Hanna pH/EC Quick Cal Solution

263.00 AED

Estimated delivery: 13 - 14 October

SKU:HI98318

The GroLine Waterproof EC/TDS Tester is made specifically for hydroponics, provides a simple, inexpensive solution to measure fertilizer concentration in a nutrient solution.

The HI98318 EC/TDS tester has a graphite sensor that reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Automatic calibration is achieved easily. Simply submerge the sensor in calibration solution and the meter will automatically detect the calibration standard (5.00 mS/cm in Quick Cal mode or 1.41 mS/cm in standard calibration mode). Temperature is automatically compensated for with the integrated temperature sensor.

Features at-a-glance

  • Waterproof
  • Fast Automatic Temperature Compensation with exposed temperature probe
  • Graphite sensors that reduce polarization effects
  • 0.5 (500 ppm) and 0.7 (700 ppm) selectable EC to TDS conversion factors
  • Single point automatic calibration using Quick Cal standard or 1.41 mS/cm in standard calibration mode
  • 250 hour battery life

Specifications

SKU HI98318
Name GroLine Waterproof EC/TDS Tester – HI98318
EC Range 0.00 to 6.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% F.S.
EC Calibration automatic,single point (1.41 mS/cm)
TDS Range 0 to 3000 ppm (0.5) CF
0 to 4000 ppm (0.7) CF
TDS Resolution 10 ppm
TDS Accuracy ±2% F.S.
TDS Calibration through EC calibration
EC/TDS Temperature Compensation automatic, 0.0 to 50.0 ºC (32.0 to 122.0 ºF)
EC to TDS Conversion Factor selectable 0.5 or 0.7 conversion factor
Temperature Range 0.0 to 50.0 °C (32.0 to 122.0 °F)
Temperature Resolution 0.1 °C (0.1 °F)
Temperature Accuracy ±0.5 °C (±1.0 °F)
Automatic Shut-Off selectable 8 min, 60 min or disabled
Battery Type/Life CR2032 Li-Ion 3V (1 pc.) / approximately 250 hours of continuous use
Environment 0 to 50 ºC (32 to 122 ºF); RH 100% max
Weight 68 g (2.4 oz.)

Ordering Info

HI98318 is supplied with Quick Cal pH and EC one point calibration solution sachet (4 pcs.), CR2032 battery (1 pc.), instruction manual, quality certificate packaged in rugged plastic carrying case.

Manuals

GroLine Waterproof EC/TDS Tester – HI98318

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart