Out of stock

GroLine pH/EC/TDS Multiparameter Probe

The HI1285-8 multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe.

Use with the HI981420 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.

  • One probe. Three measurements.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

549.00 AED

Inquire Now
SKU:HI1285-8

Hanna Instruments offers a wide variety of electrodes that are designed for many different applications. The sensing material, body material, and connection type used are just some of the design considerations.

Pre-Amplified pH Electrode

The pH electrode circuit has a built-in amplifier that serves to reduce the effects of electrical noise on the high impedance-pH measurement. Electrical noise can come from motors and pumps that are common in greenhouses. The single reference junction design of the pH electrode has a cloth junction that allows ion movement between the inner gel electrolyte and the sample being measured. The advantage of the cloth junction is that it can be extracted from the probe, exposing a fresh surface when readings become drifty or erratic. These features make this probe ideal for use in fertilizer solutions.

Amperometric EC/TDS Sensor

EC/TDS readings are performed by a two-pin amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins determines the amount of dissolved ionic solids present.

Built-In Temperature Sensor

pH and EC/TDS readings must be temperature compensated in order to obtain accurate results. The built-in temperature sensor of the HI1285-8 provides a speedy temperature reading which is then used to adjust the pH and EC/TDS results accordingly.

Polypropylene Body

The polypropylene body of the HI1285-8 houses all three sensors within a sturdy, single body design. This body material is suitable for a wide range of applications and excels in harsh grow environments due to its durability. The polypropylene plastic is a high-quality plastic that is chemically resistant to many aggressive chemicals and minimizes breakage due to accidental bumping or dropping of the electrode.

DIN Connector

The HI1285-8 uses a DIN connector. This probe is recommended for use with the HI981420 GroLine Hydroponic Nutrients Monitor for pH, EC, TDS, and Temperature.

Specifications

SKU HI1285-8
Name GroLine pH/EC/TDS Multiparameter Probe
Reference single, Ag/AgCl
Junction / Flow Rate cloth
Electrolyte gel
Max Pressure 0.2 bar
Range pH: 0 to 13/EC
Recommended Operating Temperature 0 to 50˚C (32 to 122˚F) – LT
Tip / Shape spheric (dia: 8.5 mm)
Temperature Sensor yes
Amplifier yes
Body Material polypropylene
Cable 7-pole; 1 m cable (3.3 in.)
Recommended Use hydroponics, aquaponics, greenhouses
Connection DIN
Special Note *To be used with HI981420 GroLine monitor

Manuals

GroLine pH/EC/TDS Multiparameter Probe

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration
Back to Top
Whatsapp
Product has been added to your cart