Out of stock

Groline Nutrient Dosing System-HI981413

Engineered to be an inexpensive solution for the hydroponic or greenhouse grower to maintain the ideal nutrient solution concentration level in the reservoir tank. The HI981413 GroLine Nutrient Dosing System is a complete solution with advanced process controller and a built in chemical dosing pump. Simply insert the probe and injection valve in-line with the re-circulation pump and supply the stock fertilizer to be dosed.

  • All in one solution for maintaining the proper nutrient levels
  • Industrial process probe with 1/2″ NPT threads for insertion into a re-circulation line
  • Available in three configurations including complete kit with panel mounted flow cell

Inquire Now
SKU:HI981413

HI981413 Nutrient Dosing System is designed to maintain the concentration of fertilizer nutrient solution used in hydroponics and irrigation water. The HI981413 uses an amperometric conductivity sensor to measure the amount of fertilizer in the solution. The meter can be programmed to display results as EC (electrical conductivity) or as TDS (total dissolved solids). The EC results are displayed as mS/cm while TDS is displayed as ppm with a selectable conversion factor from 0.45 to 0.99. The HI981413 was developed as a cost-effective solution for the horticulturist to maintain the ideal fertilizer concentrations by placing the probe and injection valve in-line with the re-circulation pump to provide the chemical to be dosed.

HI981413

Multi-color LCD

The HI981413 features a multi-colored LCD to show the status of the pool controller. The display is green during normal opperation, yellow if the control is not enabled, or flashes red when an alarm is triggered.

Intuitive LCD

Both conductivity or TDS and temperature are displayed with status icons that show when the pump is dosing and the control mode status.

Programmable Alarm System

Hanna controllers allow users to enable or disable the low and high-level alarms for EC/TDS. When an alarm is activated, all dosing will stop. For added safety, the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.

On-Screen Features

flow rate

Adjustable Flow Rate
The flow rate from the dosing pumps is adjustable from 0.5 to 3.5L/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point .

Automatic Proportional Pump Control

Automatic Proportional Pump Control
The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed, will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.

Tank Level/Flow Switch Input

Acid Tank Level/Flow Switch Input
The BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.

Built-in Dosing Pump

GroLine Peristaltic Pump

Peristaltic Dosing Pump

The HI981413 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.

Brushless Motor

The brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.

Long-life Peristaltic Tubing

The industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.

Conductivity electrode with flow cell

EC probe mounted in flow thorugh cell

Three Configuration Options

The HI981413 is available in multiple configurations including a meter only, meter and probe, and a complete package that includes bypass loop and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.

HI30003 Amperometric Conductivity/Temperature Probe

The HI981413 uses the HI30003 probe that incorporates both conductivity and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.

NPT Threads for In-line and Tank Mounting

The ABS body of the probe has a 1/2ā€ threaded fitting for insertion to an in-line ā€œTā€ fitting or the flow cell. The back end part of the probe has 3/4ā€ NPT threads for submersion/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .

Specifications

SKU HI981413-web
Name Groline Nutrient Dosing System-HI981413
EC Range 0.00 to 10.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy 2% F.S.
EC Calibration User calibration: automatic, one-point with standard solution (1.41 or 5.00 mS/cm)
Process calibration: single point, adjustable (±0.50 mS/cm around measured value)
The corresponding value in TDS, depends on TDS factor used
TDS Range 0 to 9900 ppm, depends on TDS factor
i.e. with TDS factor 0.5, range 50 to 5000 ppm
with TDS factor 0.7, range 70 to 7000 ppm
TDS Resolution 1 ppm
TDS Accuracy 2% F.S.
EC/TDS Temperature Compensation automatic
Temperature Correction Coefficient β can be set from 0%/°C to 2.4%/°C; default is 1.9%/°C
EC to TDS Conversion Factor TDS factor selectable from 0.45 to 0.99
EC/TDS Dosing Set Point on/off control using adjustable set point (0.10 to 10.00 mS/cm; 45 to 9900 ppm, depends on TDS factor)
proportional control 0.10 to 10.00 mS/cm; 45 to 9900 ppm, depends on TDS factor
EC/TDS Proportional Band 0.05 to 1.00 mS/cm; 23 to 990 ppm, depends on TDS factor
EC/TDS Hysteresis Band 0.05 to 0.50 mS/cm; 23 to 495 ppm, depends on TDS factor
Temperature Range -5.0 to 105.0°C; 23.0 to 221.0°F*
Temperature Resolution 0.1°C; 0.1°F
Temperature Accuracy ±0.5°C; 1°F
Dosing Control startup delay timer at power-on (0 to 600 sec.)
Pump flow control 0.5 to 3.5 Liter/hour (0.13 to 0.92 Gallon/hour) and maximum output pressure 1 atm (14 psi)
manual control for pump priming (defined in setup)
Alarm Relay Set Point triggered after 5 sec. if the controller records consecutive readings over or under threshold values
Over Dosing Control overtime protection (1 to 180 m in. or Off)
Digital Input Signal galvanically isolated external switches can be attached to stop the pump and activate the alarm (low reagent level) when the switch is open and level alarm is configured in Setup
Backlight intuitive alarm system, using red, yellow and green color coded backlight
Power Consumption 15 VA
Enclosure wall mounted, built-in pump
Power Supply 100 – 240 Vac, 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max. 95% non-condensing
IP Rating IP65
Dimensions 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)
Weight 908 g (36 oz.)

Ordering Info

HI981413-00 is supplied with HI981413 controller, HI30033 EC/TDS/temperature probe, HI7031-012 conductivity calibration solution (1413 µS/cm – 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.
HI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC/TDS/temperature probe, controller aspiration filter, controller injector, 1/2” thread, saddle for Ƙ 50 mm pipe (2), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (5 m), HI7031-012 conductivity calibration solution (1413 µS/cm – 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.
HI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH/temperature probe, flow cell for HI981413, mounting panel assembly for HI981413, controller aspiration filter, controller injector, 1/2” thread, saddle for Ƙ 50 mm pipe (3), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (15 m), barbed tubing adapter 1/2” – 6 mm with racord (2), flow cell valves (2), HI7031-012 conductivity calibration solution (1413 µS/cm – 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.

Manuals

Groline Nutrient Dosing System-HI981413

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range CheckerĀ® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality