In stock

edge® Dedicated Conductivity/TDS/Salinity Meter – HI2003

edge® groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world-class R&D. edge® is a single meter that can measure Conductivity, TDS and Salinity and is incredibly easy to use.

    • edge® EC/TDS/Salinity utilizes four ring conductivity probe technology that allows the user to measure samples from very low conductivity to very high conductivity.
    • edge® features a capacitive touch keypad that gives a distinctive, modern look. The keypad is sensitive enough to be used with laboratory gloves and has a fast response.
    • edge® features a 5.5” LCD display that you can clearly view from over 5 meters away. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCD’s in the industry.

2,470.00 AED

Estimated delivery: 26 - 27 September

SKU:HI2003-02

edge® Conductivity/TDS/Salinity is packed with many cutting-edge features to ensure accuracy and usability.

 

Digital EC Electrode

edge® EC electrode is highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge® once the electrode is plugged in. Information stored in the electrode includes model number, serial number and calibration information including the standards used and the date and time the last calibration was performed.

 

Four Ring Probe

The edge® EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built-in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide) sleeve. Both materials have excellent resistance against many aggressive chemicals.

 

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

 

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

 

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge® and charge its batteries. edge’s zero footprint design saves you valuable benchtop space.

 

Cradle and Electrode Holder

edge® is equipped with a benchtop cradle featuring an adjustable swivel electrode holder to charge and hold the meter securely in place at the optimum viewing angle.

 

edge® is incredibly thin and weighs only 8.8 oz., has an 8-hour battery life, and dual USB inputs.

 

Two USB Ports

edge® includes one standard USB for exporting data with a flash drive and a second micro-USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

 

Data Logging

edge® allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

 

Two Operating Modes

edge® offers both Basic and Standard Modes. In Basic Mode, the edge as an EC meter reduces features to simplify operation. In Basic Mode, the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% / °C and interval logging is not available. In Standard Mode, the user has options to change these settings.

Specifications

SKU HI2003-02
EC Range 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm
EC Resolution 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration 6 standards available: 84, 1413 μS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 μS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF) NoTC – can be selected to measure absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity Range 0.0 to 400.0% NaCl, 0.01 to 42.00 PSU, 0.0 to 80.0 g/L*
Salinity Resolution 0.1% NaCl, 0.01 PSU, 0.01 g/L
Salinity Accuracy ±1% of reading
Salinity Calibration 1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)
Salinity Temperature Compensation 0 to 40 g/L (with 1 g/L resolution)
Sodium Chloride Range 0.0 to 400.0% NaCl
Sodium Chloride Resolution 0.1% NaCl
Sodium Chloride Accuracy ±1% of reading
Sodium Chloride Calibration 1 point with HI 7037L 100% NaCl sea water standard (other scales through EC calibration)
EC/TDS Probe HI763100 EC/temperature probe
Power Supply 5 VDC adapter (included)
Environment 2 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 204 x 140 x 12.7mm (8in. x 5.5in. x 0.5in.)
Weight 251 g (8.82 oz)
Ordering Information edge®EC HI2003 includes: HI763100 Conductivity probe, 4 sachets of 1413 μS/cm conductivity standard, 2 sachets of 5000 μS/cm conductivity standard, 2 sachets of 12880 μS/cm conductivity standard, 2 sachets general purpose rinse solution, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificate and instruction manual.
Special Notes ‡ absolute conductivity *temperature limits will be reduced to actual probe/sensor limits
Warranty 2 years

Manuals

edge pH Manuals

Bestsellers

Chemstock for Chemicals Alcohol Ethyl (Ethanol) 99.9% Pure 3.78 litre (1 gal)

40.00 AED
  • Protects you and your family from all kinds of Viruses
  • Designed to perfection
  • Can be used for disinfecting and sanitizing all surfaces including table tops, handles, mobile phones
  • Liquid Level Indicator is provided on the can to help with measurement. Double Seal Packing to prevent any accidental leaks

Chemstock for Chemicals Sanitizing Alcohol Isopropyl Pure 1 Gal (3.78L)

40.00 AED
  • Isopropyl Alcohol 99.9percent is supplied in 1 gallon plastic bottles for easy handling.
  • The product is specified to 99.9percent purity minimum with no other contamination which ensures that it can be safely utilized as a disinfectant and sanitizing of surfaces, devices, hands, etc. or as an antiseptic.
  • Water Max. - 0.05percent, Relative density - 0.790 - 0.793. This product is strictly not to be used for potable consumption
  • SPECIFICATION: Appearance - Clear and colorless liquid, Minimum Assay (GC) - 99.9percent

Magnetic Mini-Stirrer (230V) - HI190M

306.00 AED
HI190M-1 is a compact and lightweight magnetic stirrer. This mini-stirrer is built to last having a ABS plastic housing and cover that are resistant to many harmful chemicals. The stirring speed is adjustable from 100 to 1000 RPM. The HI190M stirrer requires very little room which is valuable when laboratory benchtop space is at a premium. Speedsafe? mechanism Power indicating light Adjustable speed control
Inquire Now

Pool Line pH Tester with 0.01 pH Resolution - HI981004

182.00 AED
HI981004 Pool Line pH and temperature meter is made for measuring the pH of swimming pool, hot tub, or spa water. This tester keeps things simple with a single button operation for both ON/OFF and Calibration.
  • pH range of 0.00 to 14.00 pH
  • Automatic calibration
  • Replaceable pH probe

Marine Nitrite Low Range Checker HC Calibration Set - HI767-11

49.00 AED
The Marine Nitrite Low Range Checker? HC Calibration Check Set HI767-11 is a high-quality set of standards for the Nitrite Low Range Checker? HC - HI767 with a range of 0 to 999 ppb. Be confident in accurate measurements. The standards come with a Certificate of Analysis that provides the lot number, reference values, and expiration date for traceability when calibrating the Checker? HC.
  • Supplied with Certificate of Analysis
  • Standard value of 100 ?14 ppb nitrite at 25?
  • Reusable with long shelf-life stability
Inquire Now

Ammonia Medium Range CAL Check™ Standards - HI97715-11

618.00 AED
The HI97715-11 Ammonia Medium Range CAL Check Standards provides a simple solution to calibrating and validating the HI97715 ammonia medium range photometer. This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values and expiration date for traceability when certifying the HI97715 photometer.
  • Supplied with Certificate of Analysis
  • Standard value of 6.0 ±0.050 mg/L ammonia (as NH3-N) @ 25℃
  • Reusable with long shelf life stability

Spare pH/ORP Sensor for HI769819X Probe - HI7698194-1

811.00 AED
The HI7698194-1 is a replaceable pH/ORP sensor for use with Hanna?s family of multiparameter portable meters and probes. The sensor body is constructed of durable PEI material and contains a double ceramic junction design. The HI7698194-1 contains a glass pH sensing tip with a platinum ORP sensing pin. Each module is color coded for easy installation and integration with the probe.
  • PEI Sensor Body
  • Ceramic Double Junction Reference
  • Color Coded Sensor
Back to Top
Whatsapp
Product has been added to your cart